139 research outputs found

    Non-Destructive Inspection of Impact Damage in Composite Aircraft Panels by Ultrasonic Guided Waves and Statistical Processing.

    Get PDF
    This paper discusses a non-destructive evaluation (NDE) technique for the detection of damage in composite aircraft structures following high energy wide area blunt impact (HEWABI) from ground service equipment (GSE), such as heavy cargo loaders and other heavy equipment. The test structures typically include skin, co-cured stringers, and C-frames that are bolt-connected onto the skin with shear ties. The inspection exploits the waveguide geometry of these structures by utilizing ultrasonic guided waves and a line scan approach. Both a contact prototype and a non-contact prototype were developed and tested on realistic test panels subjected to impact in the laboratory. The results are presented in terms of receiver operating characteristic curves that show excellent probability of detection with low false alarm rates for defects located in the panel skin and stringers

    Lack of influence of GTP cyclohydrolase gene (GCH1) variations on pain sensitivity in humans

    Get PDF
    OBJECTIVES: To assess the effect of variations in GTP cyclohydrolase gene (GCH1) on pain sensitivity in humans. METHODS: Thermal and cold pain sensitivity were evaluated in a cohort of 735 healthy volunteers. Among this cohort, the clinical pain responses of 221 subjects after the surgical removal of impacted third molars were evaluated. Genotyping was done for 38 single nucleotide polymorphisms (SNPs) whose heterozygosity > 0.2 in GCH1. Influence of the genetic variations including SNPs and haplotypes on pain sensitivity were analyzed. RESULTS: Minor allele frequencies and linkage disequilibrium show significant differences in European Americans, African Americans, Hispanic Americans and Asian Americans. Association analyses in European Americans do not replicate the previously reported important influence of GCH1 variations on pain sensitivity. CONCLUSION: Considering population stratification, previously reported associations between GCH1 genetic variations and pain sensitivity appear weak or negligible in this well characterized model of pain

    Current concepts in the treatment of midshaft clavicle fractures in adults

    Get PDF
    Midshaft clavicle fractures are the most common fracture of the clavicle accounting for 80% of all clavicle fractures. Traditionally, midshaft clavicle fractures are treated with conservative treatment even when prominent displacement is observed; however, recent studies revealed that nonunion or malunion rate may be higher with conservative treatment. Moreover, recent studies have shown better functional results and patient satisfaction with surgical treatment. This review article provides a review of clavicle anatomy, describes the current clavicle fracture classification system, and outlines various treatment options including current surgical options for clavicle fracture in adults

    Genetic polymorphisms in monoamine neurotransmitter systems show only weak association with acute post-surgical pain in humans

    Get PDF
    BACKGROUND: Candidate gene studies on the basis of biological hypotheses have been a practical approach to identify relevant genetic variation in complex traits. Based on previous reports and the roles in pain pathways, we have examined the effects of variations of loci in the genes of monoamine neurotransmitter systems including metabolizing enzymes, receptors and transporters on acute clinical pain responses in humans. RESULTS: Variations in the catecholamine metabolizing enzyme genes (MAOA and COMT) showed significant associations with the maximum post-operative pain rating while the serotonin transporter gene (SLC6A4) showed association with the onset time of post-operative pain. Analgesic onset time after medication was significantly associated with the norepinephrine transporter gene (SLC6A2). However, the association between COMT genetic variation and pain sensitivity in our study differ from previous studies with small sample sizes, population stratification and pain phenotype derived from combining different types of pain stimuli. Correcting for multiple comparisons did not sustain these genetic associations between monoamine neurotransmitter systems and pain sensitivity even in this large and homogeneous sample. CONCLUSION: These results suggest that the previously reported associations between genetic polymorphisms in the monoamine neurotransmitter systems and the interindividual variability in pain responses cannot be replicated in a clinically relevant pain phenotype

    Field evaluation of physical barriers against subterranean termites and ambrosia beetles in a CLT wall envelope system

    Get PDF
    The effectiveness of physical barriers against subterranean termites was evaluated in a 34-week field test in coastal Mississippi by installing Obex11, a commercial polyethylene flashing, and Termimesh, a stainless-steel mesh in 3-ply 280mm(width) x 450mm(length) cross laminated timber (CLT) walls. Damage showed that both barriers performed significantly better than the no barrier control with respect to termite damage as evaluated by visual rating and mud tube length.  Obex11, however, like the no barrier control, was more vulnerable to attack by Ambrosiodmus minor (Stebbing), an invasive ambrosia beetle, with both treatments exhibiting significantly longer bore trails than those found in Termimesh.&nbsp

    Rotator cuff degeneration and healing after rotator cuff repair

    Get PDF
    Rotator cuff tear is a common shoulder injury that compromises both function and quality of life. Despite the prevalence of the injury and advancements in repair techniques, a significant percentage of these repairs fail. This review aims to explore the multifactorial reasons behind this failure, including the degenerative nature of the rotator cuff tendon, inherent and extrinsic factors, and the role of hypoxia in tissue degeneration. Additionally, it elucidates potential strategies for improving healing outcomes

    Evaluation of acromial spur using ultrasonography

    Get PDF
    Background The presence of an acromial spur implies a rotator cuff disorder due to impingement between the acromial spur and the rotator cuff. The purpose of the study was to observe acromial spurs using ultrasonography and to compare measurements between plain radiographs and sonograms. Methods We retrospectively enrolled 51 consecutive patients with acromial spurs, which were interpreted on preoperative plain radiographs (supraspinatus outlet view and 30° caudal tilt) and preoperative sonograms. The ultrasonography transducer was held vertically and continuously moved laterally, which corresponded to the long axis of the long head of the biceps. The distance from the most distal margin of the original acromion to the most projected point of the acromial spur was measured. Results No significant difference was found between the plain radiograph and ultrasonography measurements (p=0.186). A moderate to strong correlation was detected between the ultrasonography and supraspinatus outlet-view measurements (r=0.776, p=0.000). Conclusions Anteriorly projected acromial spurs were well-visualized by ultrasonography. No discrepancy in acromial spur length was detected between the use of plain radiography (supraspinatus outlet view and 30° caudal-tilt view) and ultrasonography. The correlation coefficients between the plain radiography and ultrasonography measurements exceeded 0.7

    Rotating Arm Internally Can Change the Arthroscopic Diagnosis of a Partial-thickness Tear of the Subscapularis

    Get PDF
    Background The aims of this study were (1) to examine the footprint of the subscapularis tendon using the traditional posterior portal and 30° arthroscope by simple internal rotation of the arm during surgery, and (2) to classify the pattern of a subscapularis partial-thickness tear. Methods This study analyzed a total of 231 patients with a partial-thickness subscapularis tear from 550 consecutive patients undergoing an arthroscopic operation who had a visualization of the subscapularis tendon footprint by internal rotation of the arm. First, the patients were classified into four categories according to the tear pattern: (1) stable lamination, (2) unstable lamination, (3) avulsion, and (4) laminated avulsion. Randomized arthroscopic videos were reviewed blindly by two independent orthopedic surgeons. The pattern of the tear of the subscapularis at the neutral position and after internal rotating the arm were assessed and compared with the treatment decision (level IV case series). Results Stable lamination, unstable lamination, avulsion, and laminated avulsion were observed in 9.1% (n=21), 20.8% (n=48), 41.1% (n=95), and 29.0% (n=67) of cases, respectively. In 145 out of 231 cases (62.8%), the decision was changed after inspecting the footprint after internal rotation of the arm, and the treatment method was changed in 116 (50.2%) cases. Conclusions In a subscapularis tendon partial-thickness tear, inspecting the footprint of the subscapularis tendon is essential to diagnosing and deciding on the appropriate treatment. In addition, simply internal rotating the arm during surgery when using the traditional posterior portal and 30° arthroscope can be a valuable method

    Arthroscopic Capsular Repair without Relaying Sutures: ‘Simple Sewing Technique’

    Get PDF
    We report a simple technique for repairing capsular tear, using only a hook-like, cannulated instrument and braided sutures without relaying steps. A No. 2 braided suture is passed through the lumen of the instrument. Under direct arthroscopic view, the tip of the instrument is passed through the side of the capsule that has previously been separated with the probe. One end of the suture is retrieved with a grasper through a separate portal. The tip is moved back without withdrawing through the skin, and reinserted into the other side of the capsule. Holding the end retrieved earlier, the other end of the suture is retrieved with a suture retriever. After complete removal of the instrument, the suture is tied through a cannula using the standard knot tying techniques. The same procedures are repeated for other required knots

    Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

    Get PDF
    Background The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman’s method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and −1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and −0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels
    • …
    corecore