3,884 research outputs found

    ???????????? ???????????? ?????? ?????????

    Get PDF
    Abstract The gravitational waves (GW170817) produced during a binary neutron star inspiral, followed by a gamma-ray burst (GRB 170817A) and afterglows from X-ray to radio wavelength, were observed. By combining the distance obtained from gravitational waves with the red shift obtained from electromagnetic waves, even the Hubble constant was estimated. This indicates the start of new era of multimessenger astronomy. In addition to the masses of inspiralling neutron stars, the tidal deformability, which depends on the inner structures of neutron stars, has been estimated from gravitational waves. This confirms that even strong interactions can be tested by using gravitational waves. In this article, we review the effect of the tidal deformability of neutron stars on the gravitational waves produced during the inspiral process and discuss the implications of the detected tidal deformability for the neutron star's equations of state

    Factors Affecting the Extrusion Rate of Ventilation Tubes

    Get PDF
    ObjectivesThe objective of this study was to determine the various factors that affect the extrusion rate of ventilation tubes (VTs), including the nature of the middle ear effusion.MethodsA retrospective chart review of 82 pediatric patients (177 ears) who received VT insertion surgery under general anesthesia was carried out to evaluate the relationship between various factors and the VT extrusion rate. The factors we analyzed included age, gender, the adenoid size, the amount and content of the middle ear effusion after myringotomy, bleeding events, associated adenoidectomy and the findings of the tympanic membrane status, the tympanometry and the audiometry of the air bone gap.ResultsThe mean extrusion time was 254 days (range, 11 to 809 days). The patients with no history of previous VT insertion had a longer extrusion time (mean, 279 days) than did the patients who had undergone previous VT insertion (mean, 203 days). The patients with serous effusion had the shortest extrusion time (mean, 190 days) as compared to those patients with glue (273 days) and pus (295 days) effusions. Other factors had no statistical significant relationship with the extrusion time.ConclusionThe mean VT extrusion time was 254 days. The VT extrusion time was significantly related to the characteristics of the middle ear effusion and a history of previous VT insertion. Thus, the nature of middle ear effusion can provide a clinical clue to predict the VT extrusion time

    Development of Automatic Mold Shot Measurement and Management System for Smart Factory

    Get PDF
    Many small- and medium-sized car-part manufacturers are either still managing their mold manually or rarely managing it, and therefore, experience significant manufacturing cost and loss in time. In such a situation, a module has been developed in the present work which can count the number of mold used. Such a module is extremely important for small and medium-sized enterprises (SMEs) applying which in the production line they will be able to manage the mold life cycle and improve product quality. This is expected to have both direct and indirect effects on their business activities. The developed system uses a photo sensor, distance measurement sensor, Atmega128 MCU, tablet pc and Bluetooth communication module. The actual module developed in this study was set up on a molding equipment for test and data were collected using an existing tablet PC. The test showed that the number of shots increased when the upper mold touched the lower mold. The maximum and minimum value between the upper and lower molds could be adjusted with the automatic mold shot measurement and management system. Therefore, any molding equipment with various upper-lower gaps will be able to apply the newly developed system

    Cerebral perfusion simulation using realistically generated synthetic trees for healthy and stroke patients

    Get PDF
    Background and objective Cerebral vascular diseases are among the most burdensome diseases faced by society. However, investigating the pathophysiology of diseases as well as developing future treatments still relies heavily on expensive in-vivo and in-vitro studies. The generation of realistic, patient-specific models of the cerebrovascular system capable of simulating hemodynamics and perfusion promises the ability to simulate diseased states, therefore accelerating development cycles using in silico studies and opening opportunities for the individual assessment of diseased states, treatment planning, and the prediction of outcomes. By providing a patient-specific, anatomically detailed and validated model of the human cerebral vascular system, we aim to provide the basis for future in silico investigations of the cerebral physiology and pathology. Methods In this retrospective study, a processing pipeline for patient-specific quantification of cerebral perfusion was developed and applied to healthy individuals and a stroke patient. Major arteries are segmented from 3T MR angiography data. A synthetic tree generation algorithm titled tissue-growth based optimization (GBO) is used to extend vascular trees beyond the imaging resolution. To investigate the anatomical accuracy of the generated trees, morphological parameters are compared against those of 7 T MRI, 9.4 T MRI, and dissection data. Using the generated vessel model, hemodynamics and perfusion are simulated by solving one-dimensional blood flow equations combined with Darcy flow equations. Results Morphological data of three healthy individuals (mean age 47 years ± 15.9 [SD], 2 female) was analyzed. Bifurcation and physiological characteristics of the synthetically generated vessels are comparable to those of dissection data. The inability of MRI based segmentation to resolve small branches and the small volume investigated cause a mismatch in the comparison to MRI data. Cerebral perfusion was estimated for healthy individuals and a stroke patient. The simulated perfusion is compared against Arterial-Spin-Labeling MRI perfusion data. Good qualitative agreement is found between simulated and measured cerebral blood flow (CBF). Ischemic regions are predicted well, however ischemia severity is overestimated. Conclusions GBO successfully generates detailed cerebral vascular models with realistic morphological parameters. Simulations based on the resulting networks predict perfusion territories and ischemic regions successfully

    Characteristics of the aberrant pyramidal tract in comparison with the pyramidal tract in the human brain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aberrant pyramidal tract (APT) refers to the collateral pathway of the pyramidal tract (PT) through the medial lemniscus in the midbrain and pons. Using diffusion tensor tractography (DTT), we investigated the characteristics of the APT in comparison with the PT in the normal human brain.</p> <p>Results</p> <p>In thirty-four (18.3%, right hemisphere: 20, left hemisphere: 14) of the 186 hemispheres, the APTs separated from the PT at the upper midbrain level, descended through the medial lemniscus from the midbrain to the pons, and then rejoined with the PT at the upper medulla. Nine (26.5%) of the 34 APTs were found to originate from the primary somatosensory cortex without a primary motor cortex origin. Values of fractional anisotropy (FA) and tract volume of the APT were lower than those of the PT (<it>P </it>< 0.05); however, no difference in mean diffusivity (MD) value was observed (<it>P ></it>0.05).</p> <p>Conclusion</p> <p>We found that the APT has different characteristics, including less directionality, fewer neural fibers, and less origin from the primary motor cortex than the PT.</p

    Tau functions as Widom constants

    Full text link
    We define a tau function for a generic Riemann-Hilbert problem posed on a union of non-intersecting smooth closed curves with jump matrices analytic in their neighborhood. The tau function depends on parameters of the jumps and is expressed as the Fredholm determinant of an integral operator with block integrable kernel constructed in terms of elementary parametrices. Its logarithmic derivatives with respect to parameters are given by contour integrals involving these parametrices and the solution of the Riemann-Hilbert problem. In the case of one circle, the tau function coincides with Widom's determinant arising in the asymptotics of block Toeplitz matrices. Our construction gives the Jimbo-Miwa-Ueno tau function for Riemann-Hilbert problems of isomonodromic origin (Painlev\'e VI, V, III, Garnier system, etc) and the Sato-Segal-Wilson tau function for integrable hierarchies such as Gelfand-Dickey and Drinfeld-Sokolov.Comment: 26 pages, 6 figure
    corecore