4 research outputs found

    A sliding stem in revision total knee arthroplasty provides stability and reduces stress shielding: An RSA study using impaction bone grafting in synthetic femora

    Get PDF
    Contains fulltext : 87345.pdf (publisher's version ) (Open Access)BACKGROUND AND PURPOSE: In the reconstruction of unicondylar femoral bone defects with morselized bone grafts in revision total knee arthroplasty, a stem extension appears to be critical to obtain adequate mechanical stability. Whether stability is still assured by this reconstruction technique in bicondylar defects has not been assessed. The disadvantage of relatively stiff stem extensions is that bone resorption is promoted due to stress shielding. We therefore designed a stem that would permit axial sliding movements of the articulating part relative to the intramedullary stem. METHODS: This stem was used in the reconstruction with impaction bone grafting (IBG) of 5 synthetic distal femora with a bicondylar defect. A cyclically axial load was applied to the prosthetic condyles to assess the stability of the reconstruction. Radiostereometry was used to determine the migrations of the femoral component with a rigidly connected stem, a sliding stem, and no stem extension. RESULTS: We found a stable reconstruction of the bicondylar femoral defects with IBG in the case of a rigidly connected stem. After disconnecting the stem, the femoral component showed substantially more migrations. With a sliding stem, rotational migrations were similar to those of a rigidly connected stem. However, the sliding stem allowed proximal migration of the condylar component, thereby compressing the IBG. INTERPRETATION: The presence of a functional stem extension is important for the stability of a bicondylar reconstruction. A sliding stem provides adequate stability, while stress shielding is reduced because compressive contact forces are still transmitted to the distal femoral bone.1 juni 201

    Similar TKA designs with differences in clinical outcome: A randomized, controlled trial of 77 knees with a mean follow-up of 6 years

    Get PDF
    Contains fulltext : 96347.pdf (publisher's version ) (Open Access)Background and purpose To try to improve the outcome of our TKAs, we started to use the CKS prosthesis. However, in a retrospective analysis this design tended to give worse results. We therefore conducted a randomized, controlled trial comparing this CKS prosthesis and our standard PFC prosthesis. Because many randomized studies between different TKA concepts generally fail to show superiority of a particular design, we hypothesized that these seemingly similar designs would not lead to any difference in clinical outcome. Patients and methods 82 patients (90 knees) were randomly allocated to one or other prosthesis, and 39 CKS prostheses and 38 PFC prostheses could be followed for mean 5.6 years. No patients were lost to follow-up. At each follow-up, patients were evaluated clinically and radiographically, and the KSS, WOMAC, VAS patient satisfaction scores and VAS for pain were recorded. Results With total Knee Society score (KSS) as primary endpoint, there was a difference in favor of the PFC group at final follow-up (p = 0.04). Whereas there was one revision in the PFC group, there were 6 revisions in the CKS group (p = 0.1). The survival analysis with any reoperation as endpoint showed better survival in the PFC group (97% (95% CI: 92-100) for the PFC group vs. 79% (95% CI: 66-92) for the CKS group) (p = 0.02). Interpretation Our hypothesis that there would be no difference in clinical outcome was rejected in this study. The PFC system showed excellent results that were comparable to those in previous reports. The CKS design had differences that had considerable negative consequences clinically. The relatively poor results have discouraged us from using this design

    The trochlea is medialized by total knee arthroplasty: an intraoperative assessment in 61 patients.

    Get PDF
    Contains fulltext : 52742.pdf (publisher's version ) (Open Access)BACKGROUND: A medialization of the femoral component in a total knee arthroplasty (TKA) causes abnormal patellar tracking, which could result in patellar instability, pain, wear, and failure. Previous reports defined medialization in relation to the neutral position of the femoral component, but omitted to compare it to the anatomical position of the trochlea. We assessed intraoperatively whether there is a systematic error of the position of the prosthetic groove relative to the anatomical trochlea. MATERIAL AND METHODS: A special instrument was developed to measure consecutively the mediolateral position of the anatomical trochlea and the mediolateral position of the prosthetic groove. 3 experienced knee surgeons determined the mediolateral error of the prosthetic groove in primary TKAs in 61 patients. RESULTS: There was a significant medial error of the prosthetic groove relative to the preoperative position of the trochlea, with a mean medial error of 2.5 mm (SD 3.3) INTERPRETATION: Our findings indicate that the trochlea is medialized by TKA. Because a conscious medialization of the femoral component in a TKA produces abnormal patellar tracking patterns, further investigations will be needed to analyze the clinical consequences of this medialization of the trochlea
    corecore