1,205 research outputs found

    Systematics of the odd-even effect in the resonance ionization of Os and Ti

    Get PDF
    Measurements of the odd-even effect in the mass spectrometric analysis of Ti and Os isotopes by resonance ionization mass spectrometry have been performed for ΔJ = + 1, 0 and -1 transitions. Under saturating conditions of the ionization and for ΔJ = + 1 transitions odd-even effects are reduced below the 0.5% level. Depending on the polarization state of the laser large odd isotope enrichments are observed for ΔJ = 0 and -1 transitions which can be reduced below the 0.5% level by depolarization of the laser field

    Laser-induced isotopic selectivity in the resonance ionization of Os

    Get PDF
    Isotope selective effects in resonance ionization mass spectrometry (RIMS) pose a potentially serious limitation to the application of this technique to the precise and reproducible measurement of isotope ratios. In order to identify some of the underlying causes of isotope selectivity in RIMS and to establish procedures for minimizing these effects, we investigated laser-induced isotope selectivity in the resonance ionization of Os. A single-color, one-photon resonant ionization scheme was used for several different transitions to produce Os photoions from a thermal atomization source. Variations in Os isotope ratios were studied as a function of laser parameters such as wavelength, bandwidth, power and polarization state. Isotope selectivity is strongly dependent on laser power and wavelength, even when the bandwidth of the laser radiation is much larger than the optical isotope shift. Variations in the ^(190)Os/^(188)Os ratio of ≈20% for a detuning of 0.8 cm^(−1) were observed on a transition with a small oscillator strength. Large even—odd isotope selectivity with a 13% depletion of ^(189)Os was observed on a ΔJ = +1 transition at low laser intensity; the odd mass Os isotopes are systematically depleted. For ΔJ = −1 and 0 transitions the isotope selectivity was reduced by polarization scrambling and for strongly saturating conditions. A technique employing the wavelength dependence of even—even isotope selectivity as an internal wavelength standard was developed to permit accurate and reproducible wavelength adjustment of the laser radiation. This technique provides control over laser-induced isotope selectivity for single-color ionization and enabled us to obtain reproducible measurements of ^(192)Os/^(188)Os and ^(189)Os/^(190)Os ratios in the saturation regime for a ΔJ = +1 transition with a precision of better than 0.5%. The application of this wavelength-tuning procedure should significantly improve the quality of RIMS isotope ratio data for many elements

    Systematics of isotope ratio measurements with resonant laser photoionization sources

    Get PDF
    Sources of laser-induced even-even and odd-even isotopic selectivity in the resonance ionization mass spectroscopy of Os and Ti have been investigated experimentally for various types of transitions. A set of conditions with regard to laser bandwidth and frequency tuning, polarization state and intensity was obtained for which isotopic selectivity is either absent or reduced below the 2 % level

    Laser-induced isotopic effects in titanium resonance ionization

    Get PDF
    Titanium isotope ratios have been measured by resonance ionization mass spectrometry (RIMS) with special emphasis on the nature of laser-induced isotopic selectivity. A pronounced wavelength dependence of even mass isotope ratios is caused by large nuclear volume effects near the magic neutron number 28 in ^(50)Ti . Optical isotope shifts, ranging from 0.07 to 0.21 cm^(-l), between ^(50)Ti and ^(46)Ti were measured for several transitions. The ^(50)Ti/^(46)Ti and ^(48)Ti/^(46)Ti ratios, nevertheless, exhibited only mass-dependent fractionation, in which the lighter Ti isotopes were enriched by ~2.5%/amu, when the laser operating parameters were properly controlled. Odd-even mass isotopic selectivity in the resonant ionization process was also examined for several transitions as a function of the laser polarization state and intensity. Under saturating conditions for a ΔJ= +1 transition and a high degree of laser depolarization for a ΔJ = 0 transition, the odd-even isotopic enhancement was reduced below the 2% level. The Ti isotope data agree with our previous results for Os and indicate that, by a careful choice of resonance transitions and laser operating parameters, isotope ratios can be measured accurately and reliably with RIMS

    Temporal trends in neonatal outcomes following iatrogenic preterm delivery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Preterm birth rates have increased substantially in the recent years mostly due to obstetric intervention. We studied the effects of increasing iatrogenic preterm birth on temporal trends in perinatal mortality and serious neonatal morbidity in the United States.</p> <p>Methods</p> <p>We used data on singleton and twin births in the United States, 1995-2005 (n = 36,399,333), to examine trends in stillbirths, neonatal deaths, and serious neonatal morbidity (5-minute Apgar ≤3, assisted ventilation ≥30 min and neonatal seizures). Preterm birth subtypes were identified using an algorithm that categorized live births <37 weeks into iatrogenic preterm births, births following premature rupture of membranes and spontaneous preterm births. Temporal changes were quantified using odds ratios (OR) and 95% confidence intervals (CI).</p> <p>Results</p> <p>Among singletons, preterm birth increased from 7.3 to 8.8 per 100 live births from 1995 to 2005, while iatrogenic preterm birth increased from 2.2 to 3.7 per 100 live births. Stillbirth rates declined from 3.4 to 3.0 per 1,000 total births from 1995-96 to 2004-05, and neonatal mortality rates declined from 2.4 to 2.1 per 1,000 live births. Temporal declines in neonatal mortality/morbidity were most pronounced at 34-36 weeks gestation and larger among iatrogenic preterm births (OR = 0.75, CI 0.73-0.77) than among spontaneous preterm births (OR = 0.82, CI 0.80-0.84); P < 0.001. Similar patterns were observed among twins, with some notable differences.</p> <p>Conclusion</p> <p>Increases in iatrogenic preterm birth have been accompanied by declines in perinatal mortality. The temporal decline in neonatal mortality/serious neonatal morbidity has been larger among iatrogenic preterm births as compared with spontaneous preterm births.</p

    Influence of soil moisture, nitrogen fertilization, and temperature on quality and amino acid composition of Thatcher wheat, The

    Get PDF
    Includes bibliographical references (pages 227-228).The protein content of Thatcher wheat grown in the growth chamber was increased by reduced water supply, nitrogen fertilization, and higher air temperatures. Soil moisture conditions had a greater influence on protein content at higher temperatures, while the largest responses to nitrogen fertilization were obtained at the medium moisture level. Changes in sedimentation value and mixing time were associated with protein content except for plants grown at 62°F. Apparently the low temperature had an adverse effect on gluten quality. The relative distribution of 9 amino acids was significantly correlated with changes in grain protein content. Only 6 amino acids gave similar high correlations with flour protein content and sedimentation value. These differences are explained on the basis of changes in the morphology of the wheat grain and the proportion of flour proteins

    Correlated Isotope Fractionation and Formation of Purple FUN Inclusions

    Get PDF
    Allende coarse-grained inclusions characterized by a distinct purple color and high spinel contents (≤ 50 vol.%) exhibit a higher frequency of FUN isotopic anomalies (≈20%) than the general CAI population (≤6%). We used the ion microprobe to measure Mg, Si, Cr and Fe isotopic compositions of three Purple Spinel-rich Inclusions (PSI = ψ) which are petrographically similar to Type B CAl to investigate: 1) variations in isotopic fractionation within inclusions, including secondary phases; 2) correlated isotopic fractionation; and 3) excess ^(26)Mg

    Absolute Determination of the 22Na(p,g) Reaction Rate in Novae

    Full text link
    Gamma-ray telescopes in orbit around the Earth are searching for evidence of the elusive radionuclide 22Na produced in novae. Previously published uncertainties in the dominant destructive reaction, 22Na(p,g)23Mg, indicated new measurements in the proton energy range of 150 to 300 keV were needed to constrain predictions. We have measured the resonance strengths, energies, and branches directly and absolutely by using protons from the University of Washington accelerator with a specially designed beamline, which included beam rastering and cold vacuum protection of the 22Na implanted targets. The targets, fabricated at TRIUMF-ISAC, displayed minimal degradation over a ~ 20 C bombardment as a result of protective layers. We avoided the need to know the stopping power, and hence the target composition, by extracting resonance strengths from excitation functions integrated over proton energy. Our measurements revealed that resonance strengths for E_p = 213, 288, 454, and 610 keV are stronger by factors of 2.4 to 3.2 than previously reported. Upper limits have been placed on proposed resonances at 198-, 209-, and 232-keV. We have re-evaluated the 22Na(p,g) reaction rate, and our measurements indicate the resonance at 213 keV makes the most significant contribution to 22Na destruction in novae. Hydrodynamic simulations including our rate indicate that the expected abundance of 22Na ejecta from a classical nova is reduced by factors between 1.5 and 2, depending on the mass of the white-dwarf star hosting the nova explosion.Comment: 20 pages, 18 figures; shortened paper, accepted in Phys. Rev.

    Estimation of circumferential fiber shortening velocity by echocardiography

    Get PDF
    The M-mode and two-dimensional echocardiograms of 40 young patients were analyzed to compare the mean circumferential fiber shortening velocity (Vcf) of the left ventricle calculated separately by two methods. The mean circumferential fiber shortening velocity was derived from the M-mode echocardiogram as minor axis shortening/ ejection time and derived from the two-dimensional echocardiogram as actual circumference change/ejection time. With computer assistance, circumference was determined from the short-axis two-dimensional echocardiography images during end-diastole and end-systole. Good correlations were obtained between the left ventricular diameter derived by M-mode echocardiography and the vertical axis during end-diastole (r = 0.79) and end-systole (r = 0.88) derived by two-dimensional echocardiography. Likewise, high correlations were noted between diameter and circumference in end-diastole (r = 0.89) and end-systole (r = 0.88). However, comparison of Vcf obtained by M-mode echocardiography with that obtained by two-dimensional echocardiography showed only fair correlation (r = 0.68). Moreover, the diameter/circumference ratio determined in end-diastole and end-systole differed significantly (p < 0.001), possibly owing to the change in geometry of the ventricular sector image during systole. Although Vcf derived by M-mode echocardiography is a useful index of left ventricular performance, it does not truly reflect the circumference change during systole
    • …
    corecore