911 research outputs found
The Use of the "Preclosure” Technique for Antegrade Aspiration Thrombectomy with Large Catheters in Acute Limb Ischemia
Purpose: This study was designed to assess retrospectively short- and mid-term outcomes of the use of a suture-mediated closure device to close the antegrade access in patients undergoing percutaneous aspiration thrombectomy with large catheters for acute leg ischemia. Methods: Between November 2005 and February 2010, a suture-mediated active closure system (ProGlide® 6F, Abbott) was placed before arterial sheath (mean 9F, range 6-12F) introduction in 101 patients (74 men, 73%, mean age 70.1±12.6years standard deviation). Data regarding mortality, complications, and factors contributing to vascular complications at the access site was collected for 6month after the intervention to detect device-related problems. As a coincidence, 77 patients had follow-up visits for a duplex ultrasound. Results: There were a total of 19 vascular complications (19%) at the puncture site, all of which were of hemorrhagic nature and none of which consisted of vessel occlusion. Two major outcome complications (2%) occurred. A retroperitoneal hematoma and a serious inguinal bleeding required additive treatment and did not result in permanent sequelae. Nine cases involved death of which eight were not attributable to the closure and one remained unclear. Successful closure was achieved in 95 patients (94%); additional manual compression was sufficient in the majority of the remaining patients. Numerous factors contributing to vascular complications were encountered. Conclusions: With acceptable short- and mid-term outcomes, the "preclose” technique can be a reliable option for the closure of a large antegrade femoral access even for patients at a high risk of vascular complications, such as those undergoing aspiration thrombectom
High Resolution Study of Magnetic Ordering at Absolute Zero
High fidelity pressure measurements in the zero temperature limit provide a
unique opportunity to study the behavior of strongly interacting, itinerant
electrons with coupled spin and charge degrees of freedom. Approaching the
exactitude that has become the hallmark of experiments on classical critical
phenomena, we characterize the quantum critical behavior of the model,
elemental antiferromagnet chromium, lightly doped with vanadium. We resolve the
sharp doubling of the Hall coefficient at the quantum critical point and trace
the dominating effects of quantum fluctuations up to surprisingly high
temperatures.Comment: 5 pages, 4 figure
Nonlinear electric field effects at a continuous Mott-Hubbard transition
We characterize the non-Ohmic portion of the conductivity at temperatures T < 1 K in the highly correlated transition metal chalcogenide Ni(S, Se)_2. Pressure tuning of the T = 0 metal-insulator transition reveals the influence of the quantum critical point and permits a direct determination of the dynamical critical exponent z = 2.7_(-0.4)^(+0.3) Within the framework of finite temperature scaling, we find that the spatial correlation length exponent ν and the conductivity exponent μ differ
Carotid Artery Stenting: A Single Center “Real World” Experience
BACKGROUND:Percutaneous carotid artery stenting (CAS) became a widely used procedure in patients with symptomatic and asymptomatic carotid artery stenosis. However its role compared to carotid endarterectomy (CAD) remains questioned. We analysed the safety of carotid artery stenting program of a prospective CAS register program of a tertiary teaching hospital.
METHOD:Between July 2003 and December 2010, 208 patients underwent CAS procedure. Baseline, procedural and follow-up data were prospectively collected. Primary peri-interventional outcome was defined as 30-day major adverse events (MAE), including death, stroke or myocardial infarction, and mid- to long-term follow-up outcome included ipsilateral stroke, myocardial infarction or death. Secondary outcome was restenosis rate ≥ 50% per lesion.
RESULTS:Unilateral carotid artery interventions were performed in 186 patients. In 22 patients CAS was performed bilaterally as stages procedures. The 30-day MAE rate was 1.9% consisting of two contralateral strokes and two ipsilateral stroke. Mean clinically follow-up was 22 months. Mid- to long-term MAE was 8.1% with 6.3% (n = 13) deaths, 1.9% (n = 4) myocardial infarctions and 0.9% (n = 2) ipsilateral stroke. The restenosis rate ≥ 50% per lesion was 4.3% at a mean follow-up of 22 months. Target lesion revascularization was performed in one patient, because of restenosis at 9 months follow-up after first CAS.
CONCLUSION:Implementation of a carotid artery stenting program at a tertiary, teaching hospital is a safe method for treatment of carotid artery stenosis. The adverse event rate during mid-to-long-term follow-up suggests an appropriate patient selection
Recommended from our members
In-situ ESEM imaging of the vapor-pressure-dependent sublimation-induced morphology of ice
Sublimation is a fundamental phase transition that has a profound impact on both natural phenomena and advanced manufacturing technologies. Although great strides have been made in the study of ice growth from melt and vapour, little consideration has been given to the effect of sublimation on the morphological features that develop in the ice microstructure. In this experimental study, we demonstrate the effect of vapour pressure on the mesoscopic faceting observed and show
that a vapour pressure-specific wavelength characterises the periodic features that arise during sublimation. The ability to control the length scale of these features not only provides us with new insights on the mesoscopic roughness of ice crystals, but also presents the potential to exploit this effect in a plethora of applications from comet dating to ice-templated tissue engineering scaffoldsM Nair also funded by Geistlich Pharma AG and Gates Cambridge Trust
Use of biomarkers or echocardiography in pulmonary embolism: the Swiss Venous Thromboembolism Registry
Background: Cardiac biomarkers and echocardiography for assessing right ventricular function are recommended to risk stratify patients with acute non-massive pulmonary embolism (PE), but it remains unclear if these tests are performed systematically in daily practice. Design and methods: Overall, 587 patients with acute non-massive PE from 18 hospitals were enrolled in the Swiss Venous Thromboembolism Registry (SWIVTER): 178 (30%) neither had a biomarker test nor an echocardiographic evaluation, 196 (34%) had a biomarker test only, 47 (8%) had an echocardiogram only and 166 (28%) had both tests. Results: Among the 409 (70%) patients with biomarkers or echocardiography, 210 (51%) had at least one positive test and 67 (16%) had positive biomarkers and right ventricular dysfunction. The ICU admission rates were 5.1% without vs. 5.6% with testing (P = 0.78), and thrombolysis or embolectomy were performed in 2.8% vs. 4.9%, respectively (P = 0.25). In multivariate analysis, syncope [odds ratio (OR): 3.49, 95% confidence interval (CI): 1.20-10.15; P = 0.022], tachycardia (OR: 2.31, 95% CI: 1.37-3.91; P = 0.002) and increasing age (OR: 1.02; 95% CI: 1.01-1.04; P < 0.001) were associated with testing of cardiac risk; outpatient status at the time of PE diagnosis (OR: 2.24, 95% CI: 1.49-3.36; P < 0.001), cancer (OR: 1.81, 95% CI: 1.17-2.79; P = 0.008) and provoked PE (OR: 1.58, 95% CI: 1.05-2.40; P = 0.029) were associated with its absence. Conclusions: Although elderly patients and those with clinically severe PE were more likely to receive a biomarker test or an echocardiogram, these tools were used in only two-thirds of the patients with acute non-massive PE and rarely in combinatio
Spin injection between epitaxial Co2.4Mn1.6Ga and an InGaAs quantum well
Electrical spin injection in a narrow [100] In0.2Ga0.8As quantum well in a GaAs p-i-n optical device is reported. The quantum well is located 300 nm from an AlGaAs Schottky barrier and this system is used to compare the efficiencies and temperature dependences of spin injection from Fe and the Heusler alloy Co2.4Mn1.6Ga grown by molecular-beam epitaxy. At 5 K, the injected electron spin polarizations for Fe and Co2.4Mn1.6Ga injectors are 31% and 13%, respectively. Optical detection is carried out in the oblique Hanle geometry. A dynamic nuclear polarization effect below 10 K enhances the magnetic field seen by the injected spins in both devices. The Co2.4Mn1.6Ga thin films are found to have a transport spin polarization of similar to 50% by point contact Andreev reflection conductivity measurements. (c) 2005 American Institute of Physics
- …