14 research outputs found

    Graphical user interface for analyzing radiological data

    No full text
    Brain research is increasingly focusing on critically sampled multimodal data. Due to the complexity of the brain multiple measures are analyzed simultaneously to bring forth a more comprehensive picture of brain functions. Furthermore the data has markedly increased in size, which places new demands for analysis tools. This master’s thesis presents a MRI-compatible multimodal measurement arrangement, a Hepta-scan concept and a toolbox (Nifty) for analyzing the measurements. The concept measures brain (MREG), non-invasive blood pressure (NIBP), electroencephalography (EEG), near infrared spectroscopy (NIRS) and anesthesia data in synchrony. Nifty combines several existing and newly developed software to create a simple access point for all available tools. It includes a database which holds information of a large amount of data obtained in the multimodal measurements. This thesis presents the software and hardware parts of the Hepta-scan concept and explains the workflow in it. Finally the Nifty toolbox design is presented and the functionality of it explained.Aivotutkimus keskittyy entistä enemmän kriittisesti näytteistettyyn multimodaalisen dataan. Aivojen monimutkaisuus vaatii useiden mittareiden analysointia samanaikaisesti, jotta saadaan kattava kuva aivojen toiminnasta. Lisäksi aiempaa tarkempi kuvantaminen lisää datan määrää, mikä asettaa uusia vaatimuksia analyysityökaluille. Tämä diplomityö esittää MRI -yhteensopivan multimodaalisen mittausjärjestelmän, Hepta-scan konseptin ja työkalupaketin (Nifty) mittausten analysointiin. Konsepti mittaa aivoja (MREG), noninvasiivista verenpainetta (NIBP), aivosähkökäyrää (EEG), lähi-infrapunaspektroskopiaa (NIRS) ja anestesiadataa synkronoidusti. Nifty yhdistää useita olemassa olevia ja uusia kehitettyjä ohjelmia, jotka muodostavat yksinkertaisen käynnistyspisteen kaikille työkaluille. Se sisältää tietokantajärjestelmän, joka pitää yllä informaatiota multimodaalisista mittauksista. Tämä työ esittää ohjelmisto- ja laitteistopuolen Hepta-scan konseptista, ja selittää sen työnkulun. Lopuksi työkalupaketti, Niftyn rakenne esitetään, ja sen toiminnot selitetään

    Increased very low frequency pulsations and decreased cardiorespiratory pulsations suggest altered brain clearance in narcolepsy

    No full text
    Abstract Background: Narcolepsy is a chronic neurological disease characterized by daytime sleep attacks, cataplexy, and fragmented sleep. The disease is hypothesized to arise from destruction or dysfunction of hypothalamic hypocretin-producing cells that innervate wake-promoting systems including the ascending arousal network (AAN), which regulates arousal via release of neurotransmitters like noradrenalin. Brain pulsations are thought to drive intracranial cerebrospinal fluid flow linked to brain metabolite transfer that sustains homeostasis. This flow increases in sleep and is suppressed by noradrenalin in the awake state. Here we tested the hypothesis that narcolepsy is associated with altered brain pulsations, and if these pulsations can differentiate narcolepsy type 1 from healthy controls. Methods: In this case-control study, 23 patients with narcolepsy type 1 (NT1) were imaged with ultrafast fMRI (MREG) along with 23 age- and sex-matched healthy controls (HC). The physiological brain pulsations were quantified as the frequency-wise signal variance. Clinical relevance of the pulsations was investigated with correlation and receiving operating characteristic analysis. Results: We find that variance and fractional variance in the very low frequency (MREGvlf) band are greater in NT1 compared to HC, while cardiac (MREGcard) and respiratory band variances are lower. Interestingly, these pulsations differences are prominent in the AAN region. We further find that fractional variance in MREGvlf shows promise as an effective bi-classification metric (AUC = 81.4%/78.5%), and that disease severity measured with narcolepsy severity score correlates with MREGcard variance (R = −0.48, p = 0.0249). Conclusions: We suggest that our novel results reflect impaired CSF dynamics that may be linked to altered glymphatic circulation in narcolepsy type 1

    Continuous blood pressure recordings simultaneously with functional brain imaging:studies of the glymphatic system

    No full text
    Abstract The lymph system is responsible for cleaning the tissues of metabolic waste products, soluble proteins and other harmful fluids etc. Lymph flow in the body is driven by body movements and muscle contractions. Moreover, it is indirectly dependent on the cardiovascular system, where the heart beat and blood pressure maintain force of pressure in lymphatic channels. Over the last few years, studies revealed that the brain contains the so-called glymphatic system, which is the counterpart of the systemic lymphatic system in the brain. Similarly, the flow in the glymphatic system is assumed to be mostly driven by physiological pulsations such as cardiovascular pulses. Thus, continuous measurement of blood pressure and heart function simultaneously with functional brain imaging is of great interest, particularly in studies of the glymphatic system. We present our MRI compatible optics based sensing system for continuous blood pressure measurement and show our current results on the effects of blood pressure variations on cerebral brain dynamics, with a focus on the glymphatic system. Blood pressure was measured simultaneously with near-infrared spectroscopy (NIRS) combined with an ultrafast functional brain imaging (fMRI) sequence magnetic resonance encephalography (MREG, 3D brain 10 Hz sampling rate)

    Combined spatiotemporal ICA (stICA) for continuous and dynamic lag structure analysis of MREG data

    No full text
    Abstract This study investigated lag structure in the resting-state fMRI by applying a novel independent component (ICA) method to magnetic resonance encephalography (MREG) data. Briefly, the spatial ICA (sICA) was used for defining the frontal and back nodes of the default mode network (DMN), and the temporal ICA (tICA), which is enabled by the high temporal resolution of MREG (TR=100ms), was used to separate both neuronal and physiological components of these two spatial map regions. Subsequently, lag structure was investigated between the frontal (DMNvmpf) and posterior (DMNpcc) DMN nodes using both conventional method with all-time points and a sliding-window approach. A rigorous noise exclusion criterion was applied for tICs to remove physiological pulsations, motion and system artefacts. All the de-noised tICs were used to calculate the null-distributions both for expected lag variability over time and over subjects. Lag analysis was done for the three highest correlating denoised tICA pairs. Mean time lag of 0.6 s (± 0.5 std) and mean absolute correlation of 0.69 (± 0.08) between the highest correlating tICA pairs of DMN nodes was observed throughout the whole analyzed period. In dynamic 2 min window analysis, there was large variability over subjects as ranging between 1–10 sec. Directionality varied between these highly correlating sources an average 28.8% of the possible number of direction changes. The null models show highly consistent correlation and lag structure between DMN nodes both in continuous and dynamic analysis. The mean time lag of a null-model over time between all denoised DMN nodes was 0.0 s and, thus the probability of having either DMNpcc or DMNvmpf as a preceding component is near equal. All the lag values of highest correlating tICA pairs over subjects lie within the standard deviation range of a null-model in whole time window analysis, supporting the earlier findings that there is a consistent temporal lag structure across groups of individuals. However, in dynamic analysis, there are lag values exceeding the threshold of significance of a null-model meaning that there might be biologically meaningful variation in this measure. Taken together the variability in lag and the presence of high activity peaks during strong connectivity indicate that individual avalanches may play an important role in defining dynamic independence in resting state connectivity within networks

    Cardiovascular pulsatility increases in visual cortex before blood oxygen level dependent response during stimulus

    No full text
    Abstract The physiological pulsations that drive tissue fluid homeostasis are not well characterized during brain activation. Therefore, we used fast magnetic resonance encephalography (MREG) fMRI to measure full band (0–5 Hz) blood oxygen level-dependent (BOLDFB) signals during a dynamic visual task in 23 subjects. This revealed brain activity in the very low frequency (BOLDVLF) as well as in cardiac and respiratory bands. The cardiovascular hemodynamic envelope (CHe) signal correlated significantly with the visual BOLDVLF response, considered as an independent signal source in the V1-V2 visual cortices. The CHe preceded the canonical BOLDVLF response by an average of 1.3 (± 2.2) s. Physiologically, the observed CHe signal could mark increased regional cardiovascular pulsatility following vasodilation

    Breath hold effect on cardiovascular brain pulsations:a multimodal magnetic resonance encephalography study

    No full text
    Abstract Ultra-fast functional magnetic resonance encephalography (MREG) enables separate assessment of cardiovascular, respiratory, and vasomotor waves from brain pulsations without temporal aliasing. We examined effects of breath hold- (BH) related changes on cardiovascular brain pulsations using MREG to study the physiological nature of cerebrovascular reactivity. We used alternating 32 s BH and 88 s resting normoventilation (NV) to change brain pulsations during MREG combined with simultaneously measured respiration, continuous non-invasive blood pressure, and cortical near-infrared spectroscopy (NIRS) in healthy volunteers. Changes in classical resting-state network BOLD-like signal and cortical blood oxygenation were reproduced based on MREG and NIRS signals. Cardiovascular pulsation amplitudes of MREG signal from anterior cerebral artery, oxygenated hemoglobin concentration in frontal cortex, and blood pressure decreased after BH. MREG cardiovascular pulse amplitudes in cortical areas and sagittal sinus increased, while cerebrospinal fluid and white matter remained unchanged. Respiratory centers in the brainstem — hypothalamus — thalamus — amygdala network showed strongest increases in cardiovascular pulsation amplitude. The spatial propagation of averaged cardiovascular impulses altered as a function of successive BH runs. The spread of cardiovascular pulse cycles exhibited a decreasing spatial similarity over time. MREG portrayed spatiotemporally accurate respiratory network activity and cardiovascular pulsation dynamics related to BH challenges at an unpreceded high temporal resolution

    Sampling rate effects on resting state fMRI metrics

    No full text
    Abstract Low image sampling rates used in resting state functional magnetic resonance imaging (rs-fMRI) may cause aliasing of the cardiorespiratory pulsations over the very low frequency (VLF) BOLD signal fluctuations which reflects to functional connectivity (FC). In this study, we examine the effect of sampling rate on currently used rs-fMRI FC metrics. Ultra-fast fMRI magnetic resonance encephalography (MREG) data, sampled with TR 0.1 s, was downsampled to different subsampled repetition times (sTR, range 0.3–3 s) for comparisons. Echo planar k-space sampling (TR 2.15 s) and interleaved slice collection schemes were also compared against the 3D single shot trajectory at 2.2 s sTR. The quantified connectivity metrics included stationary spatial, time, and frequency domains, as well as dynamic analyses. Time domain methods included analyses of seed-based functional connectivity, regional homogeneity (ReHo), coefficient of variation, and spatial domain group level probabilistic independent component analysis (ICA). In frequency domain analyses, we examined fractional and amplitude of low frequency fluctuations. Aliasing effects were spatially and spectrally analyzed by comparing VLF (0.01–0.1 Hz), respiratory (0.12–0.35 Hz) and cardiac power (0.9–1.3 Hz) FFT maps at different sTRs. Quasi-periodic pattern (QPP) of VLF events were analyzed for effects on dynamic FC methods. The results in conventional time and spatial domain analyses remained virtually unchanged by the different sampling rates. In frequency domain, the aliasing occurred mainly in higher sTR (1–2 s) where cardiac power aliases over respiratory power. The VLF power maps suffered minimally from increasing sTRs. Interleaved data reconstruction induced lower ReHo compared to 3D sampling (p < 0.001). Gradient recalled echo-planar imaging (EPI BOLD) data produced both better and worse metrics. In QPP analyses, the repeatability of the VLF pulse detection becomes linearly reduced with increasing sTR. In conclusion, the conventional resting state metrics (e.g., FC, ICA) were not markedly affected by different TRs (0.1–3 s). However, cardiorespiratory signals showed strongest aliasing in central brain regions in sTR 1–2 s. Pulsatile QPP and other dynamic analyses benefit linearly from short TR scanning

    Dynamic lag analysis reveals atypical brain information flow in autism spectrum disorder

    No full text
    Abstract This study investigated whole‐brain dynamic lag pattern variations between neurotypical (NT) individuals and individuals with autism spectrum disorder (ASD) by applying a novel technique called dynamic lag analysis (DLA). The use of 3D magnetic resonance encephalography data with repetition time = 100 msec enables highly accurate analysis of the spread of activity between brain networks. Sixteen resting‐state networks (RSNs) with the highest spatial correlation between NT individuals (n = 20) and individuals with ASD (n = 20) were analyzed. The dynamic lag pattern variation between each RSN pair was investigated using DLA, which measures time lag variation between each RSN pair combination and statistically defines how these lag patterns are altered between ASD and NT groups. DLA analyses indicated that 10.8% of the 120 RSN pairs had statistically significant (P‐value <0.003) dynamic lag pattern differences that survived correction with surrogate data thresholding. Alterations in lag patterns were concentrated in salience, executive, visual, and default‐mode networks, supporting earlier findings of impaired brain connectivity in these regions in ASD. 92.3% and 84.6% of the significant RSN pairs revealed shorter mean and median temporal lags in ASD versus NT, respectively. Taken together, these results suggest that altered lag patterns indicating atypical spread of activity between large‐scale functional brain networks may contribute to the ASD phenotype

    Increased interictal synchronicity of respiratory related brain pulsations in epilepsy

    No full text
    Abstract Respiratory brain pulsations have recently been shown to drive electrophysiological brain activity in patients with epilepsy. Furthermore, functional neuroimaging indicates that respiratory brain pulsations have increased variability and amplitude in patients with epilepsy compared to healthy individuals. To determine whether the respiratory drive is altered in epilepsy, we compared respiratory brain pulsation synchronicity between healthy controls and patients. Whole brain fast functional magnetic resonance imaging was performed on 40 medicated patients with focal epilepsy, 20 drug-naïve patients and 102 healthy controls. Cerebrospinal fluid associated respiratory pulsations were used to generate individual whole brain respiratory synchronization maps, which were compared between groups. Finally, we analyzed the seizure frequency effect and diagnostic accuracy of the respiratory synchronization defect in epilepsy. Respiratory brain pulsations related to the verified fourth ventricle pulsations were significantly more synchronous in patients in frontal, periventricular and mid-temporal regions, while the seizure frequency correlated positively with synchronicity. The respiratory brain synchronicity had a good diagnostic accuracy (ROCAUC = 0.75) in discriminating controls from medicated patients. The elevated respiratory brain synchronicity in focal epilepsy suggests altered physiological effect of cerebrospinal fluid pulsations possibly linked to regional brain water dynamics involved with interictal brain physiology
    corecore