2,223 research outputs found
Characterization of a Quantum Light Source Based on Spontaneous Parametric Down-Conversion
We have built a quantum light source capable of producing different types of
quantum states. The quantum light source is based on entangled state
preparation in the process of spontaneous parametric down-conversion. The
single-photon detection rate of eight-hundred thousand per second demonstrates
that we have created a bright state-of-the-art quantum light source. As a part
of the characterization we measured two-photon quantum interference in a
Hong-Ou-Mandel interferometer.Comment: 33 page
Evidence for multiple structural genes for the γ chain of human fetal hemoglobin
A sequence with a specific residue at each position was proposed for the γ chain of human fetal hemoglobin by Schroeder et al. (1) after a study in which hemoglobin from a number of individual infants was used. We have now examined in part the fetal hemoglobin components of 17 additional infants and have observed that position 136 of the γ chain may be occupied not only by a glycyl residue, as previously reported, but also by an alanyl residue
Interference of bovine hemoglobin-based oxygen carrier-201 (Hemopure) on four hematology analyzers
Introduction: Hemoglobin-based oxygen carriers, for example HBOC-201 (Hemopure), are aimed to bridge acute anemia when blood transfusion is not available or refused by the patient. However, since HBOC-201 appears free in plasma, it interferes with laboratory tests. This study presents an overview of HBOC-201 interference on four commonly used hematology analyzers and suggests treatment monitoring possibilities. Methods: Blood samples were spiked with therapeutic doses of HBOC-201 and nine hematology parameters were measured with the Sysmex XN-20, Siemens Advia 2120i, Abbott Alinity Hq and Abbot Cell Dyn Sapphire hematology analyzers. The results were compared to control samples and the bias was determined. Results: Most parameters, including all cell counts, hematocrit and MCV, showed a non-significant bias compared to control. However, the standard, total hemoglobin (Hb) measurement as well as MCH and MCHC showed poor agreement with control, as HBOC-201 was included in this measurement. Yet, the flow cytometry-based Hb method quantified intracellular Hb in spiked samples, excluding HBOC-201. Conclusion: Of all included hematology parameters, only total Hb and the associated MCH and MCHC suffered from interference. In contrast, the flow cytometry-based Hb measurement provided an accurate measure of intracellular Hb. The difference between total Hb and cellular Hb represents the HBOC-201 concentration and can be used to monitor HBOC-201 treatment.</p
Yields of oxidized volatile organic compounds during the OH radical initiated oxidation of isoprene, methyl vinyl ketone, and methacrolein under high-NO_x conditions
We present first-generation and total production yields of glyoxal, methylglyoxal, glycolaldehyde, and hydroxyacetone from the oxidation of isoprene, methyl vinyl ketone (MVK), and methacrolein (MACR) with OH under high NO_x conditions. Several of these first-generation yields are not included in commonly used chemical mechanisms, such as the Leeds Master Chemical Mechanism (MCM) v. 3.2. The first-generation yield of glyoxal from isoprene was determined to be 2.1 (±0.6)%. Inclusion of first-generation production of glyoxal, glycolaldehyde and hydroxyacetone from isoprene greatly improves performance of an MCM based model during the initial part of the experiments. In order to further improve performance of the MCM based model, higher generation glyoxal production was reduced by lowering the first-generation yield of glyoxal from C5 hydroxycarbonyls. The results suggest that glyoxal production from reaction of OH with isoprene under high NO_x conditions can be approximated by inclusion of a first-generation production term together with secondary production only via glycolaldehyde. Analogously, methylglyoxal production can be approximated by a first-generation production term from isoprene, and secondary production via MVK, MACR and hydroxyacetone. The first-generation yields reported here correspond to less than 5% of the total oxidized yield from isoprene and thus only have a small effect on the fate of isoprene. However, due to the abundance of isoprene, the combination of first-generation yields and reduced higher generation production of glyoxal from C5 hydroxycarbonyls is important for models that include the production of the small organic molecules from isoprene
Decision support for crew rostering at NS
This paper describes a method for solving the cyclic crew rostering problem (CCRP). This is the problem of cyclically ordering a set of duties for a number of crew members, such that several complex constraints are satisfied and such that the quality of the obtained roster is as high as possible. The described method was tested on a number of instances of NS, the largest operator of passenger trains in the Netherlands. These instances involve the generation of rosters for groups of train drivers or conductors of NS. The tests show that high quality solutions for practical instances of the CCRP can be generated in an acceptable amount of computing time. Finally, we describe an experiment where we constructed rosters in an automatic way for a group of conductors. They preferred our—generated—rosters over their own manually constructed rosters
Controlling the quality factor of a tuning-fork resonance between 9 K and 300 K for scanning-probe microscopy
We study the dynamic response of a mechanical quartz tuning fork in the
temperature range from 9 K to 300 K. Since the quality factor Q of the
resonance strongly depends on temperature, we implement a procedure to control
the quality factor of the resonance. We show that we are able to dynamically
change the quality factor and keep it constant over the whole temperature
range. This procedure is suitable for applications in scanning probe
microscopy.Comment: 5 pages, 6 figure
Toezicht en compliance
Two contradictory developments characterize modern corporate regulation. On the one hand, the demand for public supervision and control is ever increasing. New supervisory authorities are founded and existing agencies are assigned more power. On the other hand, corporations should be trusted for their abilities to regulate themselves and monitor their compliance status through i
Inhibited spontaneous emission of quantum dots observed in a 3D photonic band gap
We present time-resolved emission experiments of semiconductor quantum dots
in silicon 3D inverse-woodpile photonic band gap crystals. A systematic study
is made of crystals with a range of pore radii to tune the band gap relative to
the emission frequency. The decay rates averaged over all dipole orientations
are inhibited by a factor of 10 in the photonic band gap and enhanced up to 2?
outside the gap, in agreement with theory. We discuss the effects of spatial
inhomogeneity, nonradiative decay, and transition dipole orientations on the
observed inhibition in the band gap.Comment: 5 figures, update author lis
Collineation group as a subgroup of the symmetric group
Let be the projectivization (i.e., the set of one-dimensional vector
subspaces) of a vector space of dimension over a field. Let be a
closed (in the pointwise convergence topology) subgroup of the permutation
group of the set . Suppose that contains the
projective group and an arbitrary self-bijection of transforming a
triple of collinear points to a non-collinear triple. It is well-known from
\cite{KantorMcDonough} that if is finite then contains the
alternating subgroup of .
We show in Theorem \ref{density} below that , if
is infinite.Comment: 9 page
- …