350 research outputs found

    Intestinal current measurements to diagnose cystic fibrosis

    Get PDF
    AbstractElectrophysiological techniques are essential for the diagnosis of cystic fibrosis. In the past ten years intestinal current measurements has emerged as valuable tool for this purpose. This overview highlights the objectives, methodology and current protocols to diagnose cystic fibrosis by intestinal current measurement on rectal biopsies

    Role of anion exchangers in Cl- and HCO3- secretion by the human airway epithelial cell line Calu-3

    Get PDF
    Despite the importance of airway surface liquid pH in the lung's defenses against infection, the mechanism of airway HCO3- secretion remains unclear. Our aim was to assess the contribution of apical and basolateral Cl-/HCO3- exchangers to Cl- and HCO3- transport in the Calu-3 cell line, derived from human airway submucosal glands. Changes in intracellular pH (pH(i)) were measured following substitution of Cl- with gluconate. Apical Cl- substitution led to an alkalinization in forskolin-stimulated cells, indicative of Cl-/HCO3- exchange. This was unaffected by the anion exchange inhibitor DIDS but inhibited by the CFTR blocker CFTRinh-172, suggesting that the HCO3- influx might occur via CFTR, rather than a solute carrier family 26 (SLC26) exchanger, as recently proposed. The anion selectivity of the recovery process more closely resembled that of CFTR than an SLC26 exchanger, and quantitative RT-PCR showed only low levels of SLC26 exchanger transcripts relative to CFTR and anion exchanger 2 (AE2). For pHi to rise to observed values (similar to 7.8) through HCO3- entry via CFTR, the apical membrane potential must reverse to at least + 20 mV following Cl- substitution; this was confirmed by perforated-patch recordings. Substitution of basolateral Cl- evoked a DIDS-sensitive alkalinization, attributed to Cl-/HCO3- exchange via AE2. This appeared to be abolished in forskolin-stimulated cells but was unmasked by blocking apical efflux of HCO3- via CFTR. We conclude that Calu-3 cells secrete HCO3- predominantly via CFTR, and, contrary to previous reports, the basolateral anion exchanger AE2 remains active during stimulation, providing an important pathway for basolateral Cl- uptake

    Combined Treatment Strategies for Microtubule Stabilizing Agent-Resistant Tumors

    Get PDF
    Background: Resistance to microtubule-stabilizing agents is a major hurdle for successful cancer therapy. We investigated combined treatment of microtubule-stabilizing agents (MSAs) with inhibitors of angiogenesis to overcome MSA resistance. Methods: Treatment regimens of clinically relevant MSAs (patupilone and paclitaxel) and antiangiogenic agents (everolimus and bevacizumab) were investigated in genetically defined MSA-resistant lung (A549EpoB40) and colon adenocarcinoma (SW480) tumor xenografts in nude mice (CD1-Foxn1, ICRnu; 5-14 per group). Tumor growth delays were calculated by Kaplan-Meier analysis with Holm-Sidak tests. All statistical tests were two-sided. Results: Inhibition of mTOR-kinase by everolimus only minimally reduced the proliferative activity of β tubulin-mutated lung adenocarcinoma cells alone and in combination with the MSA patupilone, but everolimus inhibited expression and secretion of vascular endothelial growth factor (VEGF) from these cells. mTOR-kinase inhibition strongly sensitized tumor xenografts derived from these otherwise MSA-resistant tumor cells to patupilone. Tumors treated with the combined modality of everolimus and patupilone had statistically significantly reduced tumor volume and stronger tumor growth delay (16.2±1.01 days) than control- (7.7±0.3 days, P = .004), patupilone- (10±0.97 days, P = .009), and everolimus-treated (10.6±1.4 days, P = .014) tumors. A combined treatment modality with bevacizumab also resensitized this MSA-refractory tumor model to patupilone. Treatment combination also strongly reduced microvessel density, corroborating the relevance of VEGF targeting for the known antivasculature-directed potency of MSA alone in MSA-sensitive tumor models. Resensitization to MSAs was also probed in P glycoprotein-overexpressing SW480-derived tumor xenografts. Different bevacizumab regimens also sensitized this otherwise-resistant tumor model to clinically relevant MSA paclitaxel. Conclusions: A treatment combination of MSAs with antiangiogenic agents is potent to overcome tumor cell-linked MSA resistance and should be considered as strategy for MSA-refractory tumor entitie

    Ex vivo propagation in a novel 3D high-throughput co-culture system for multiple myeloma

    Get PDF
    PURPOSE: Multiple myeloma (MM) remains an incurable hematologic malignancy which ultimately develops drug resistance and evades treatment. Despite substantial therapeutic advances over the past years, the clinical failure rate of preclinically promising anti-MM drugs remains substantial. More realistic in vitro models are thus required to better predict clinical efficacy of a preclinically active compound. METHODS: Here, we report on the establishment of a conical agarose 3D co-culture platform for the preclinical propagation of primary MM cells ex vivo. Cell growth was compared to yet established 2D and liquid overlay systems. MM cell lines (MMCL: RPMI-8226, U266, OPM-2) and primary patient specimens were tested. Drug sensitivity was examined by exploring the cytotoxic effect of bortezomib and the deubiquitinase inhibitor auranofin under various conditions. RESULTS: In contrast to 2D and liquid overlay, cell proliferation in the 3D array followed a sigmoidal curve characterized by an initial growth delay but more durable proliferation of MMCL over 12 days of culture. Primary MM specimens did not expand in ex vivo monoculture, but required co-culture support by a human stromal cell line (HS-5, MSP-1). HS-5 induced a \u3e fivefold increase in cluster volume and maintained long-term viability of primary MM cells for up to 21 days. Bortezomib and auranofin induced less cytotoxicity under 3D vs. 2D condition and in co- vs. monoculture, respectively. CONCLUSIONS: This study introduces a novel model that is capable of long-term propagation and drug testing of primary MM specimens ex vivo overcoming some of the pitfalls of currently available in vitro models

    Treatment With Erythropoietin for Patients With Optic Neuritis: Long-term Follow-up.

    Get PDF
    BACKGROUND AND OBJECTIVE Erythropoietin (EPO) is a candidate neuroprotective drug. We assessed its long-term safety and efficacy as an adjunct to methylprednisolone in patients with optic neuritis and focused on conversions to multiple sclerosis (MS). METHODS The TONE trial randomized 108 patients with acute optic neuritis but without previously known MS to either 33,000 IU EPO or placebo in conjunction with 1,000 mg methylprednisolone daily for 3 days. After reaching the primary end point at 6 months, we conducted an open-label follow-up 2 years after randomization. RESULTS The follow-up was attended by 83 of 103 initially analyzed patients (81%). There were no previously unreported adverse events. The adjusted treatment difference of peripapillary retinal nerve fiber layer atrophy in relation to the fellow eye at baseline was 1.27 µm (95% CI -6.45 to 8.98, p = 0.74). The adjusted treatment difference in low-contrast letter acuity was 2.87 on the 2.5% Sloan chart score (95% CI -7.92 to 13.65). Vision-related quality of life was similar in both treatment arms (National Eye Institute Visual Functioning Questionnaire median score [IQR]: 94.0 [88.0 to 96.9] in the EPO and 93.4 [89.5 to 97.4] in the placebo group). The rate of multiple sclerosis-free survival was 38% in the placebo and 53% in the EPO group (hazard ratio: 1.67, 95% CI 0.96 to 2.88, p = 0.068). DISCUSSION In line with the results at 6 months, we found neither structural nor functional benefits in the visual system of patients with optic neuritis as a clinically isolated syndrome, 2 years after EPO administration. Although there were fewer early conversions to MS in the EPO group, the difference across the 2-year window was not statistically significant. CLASSIFICATION OF EVIDENCE This study provides Class II evidence that for patients with acute optic neuritis, EPO as an adjunct to methylprednisolone is well tolerated and does not improve long-term visual outcomes. TRIAL REGISTRATION INFORMATION The trial was preregistered before commencement at clinicaltrials.gov (NCT01962571)

    Prices of Orphan Drugs in Four Western European Countries Before and After Market Exclusivity Expiry:A Cross-Country Comparison of List Prices and Purchase Prices

    Get PDF
    Background: Increasing pharmaceutical expenditure challenges the sustainability and accessibility of healthcare systems across Europe. Confidentiality restraints hinder assessment of actual prices of Orphan Medicinal Products (OMPs). Hence, we assessed the real prices of brand-name OMPs around market exclusivity expiry (MEE). Objective: We aimed to explore developments in published list prices (LPs) and confidential hospital purchase prices (PPs) of brand-name OMPs relative to their market exclusivity status in Western European countries with similar GDPs. Methods: We analyzed LPs and PPs of 13 selected OMPs purchased by university hospitals in Western European countries between 2000 and 2020. For confidentially reasons, proportions were used, with the Dutch LPs of the selected OMPs at the year of MEE serving as reference values. PPs included pre-purchase discounts. Rebates were not considered. Results: Data were analyzed from hospitals in Denmark (DK) (n = 1), France (FR) (n = 1), Germany (DE) (n = 2), and the Netherlands (NL) (n = 1). Average LPs and PPs of included OMPs dropped gradually but limited over time, with no explicit price drop after MEE. LP levels differed more per country than PP levels: LP range before MEE was 164% (DE)–101% (FR) and after MEE was 135% (DE)–82% (FR); PP range before MEE was 150% (DE)–102% (FR) and after MEE was 107% (DE)–80% (FR). Overall differences between LPs and PPs were &lt; 3% in all countries, except for Denmark. Conclusion: No evident price drops of included brand-name OMPs were observed around MEE and differences in purchase prices are modest in the selected Western European countries. Results were not subject to significance testing. More robust data are needed to strengthen negotiations with suppliers.</p

    The behaviour of political parties and MPs in the parliaments of the Weimar Republic

    Get PDF
    Copyright @ 2012 The Authors. This is the author's accepted manuscript. The final published article is available from the link below.Analysing the roll-call votes of the MPs of the Weimar Republic we find: (1) that party competition in the Weimar parliaments can be structured along two dimensions: an economic left–right and a pro-/anti-democratic. Remarkably, this is stable throughout the entire lifespan of the Republic and not just in the later years and despite the varying content of votes across the lifespan of the Republic, and (2) that nearly all parties were troubled by intra-party divisions, though, in particular, the national socialists and communists became homogeneous in the final years of the Republic.Zukunftskolleg, University of Konstan

    Falsification Of The Atmospheric CO2 Greenhouse Effects Within The Frame Of Physics

    Full text link
    The atmospheric greenhouse effect, an idea that many authors trace back to the traditional works of Fourier (1824), Tyndall (1861), and Arrhenius (1896), and which is still supported in global climatology, essentially describes a fictitious mechanism, in which a planetary atmosphere acts as a heat pump driven by an environment that is radiatively interacting with but radiatively equilibrated to the atmospheric system. According to the second law of thermodynamics such a planetary machine can never exist. Nevertheless, in almost all texts of global climatology and in a widespread secondary literature it is taken for granted that such mechanism is real and stands on a firm scientific foundation. In this paper the popular conjecture is analyzed and the underlying physical principles are clarified. By showing that (a) there are no common physical laws between the warming phenomenon in glass houses and the fictitious atmospheric greenhouse effects, (b) there are no calculations to determine an average surface temperature of a planet, (c) the frequently mentioned difference of 33 degrees Celsius is a meaningless number calculated wrongly, (d) the formulas of cavity radiation are used inappropriately, (e) the assumption of a radiative balance is unphysical, (f) thermal conductivity and friction must not be set to zero, the atmospheric greenhouse conjecture is falsified.Comment: 115 pages, 32 figures, 13 tables (some typos corrected

    Finite volume analysis of temperature effects induced by active MRI implants with cylindrical symmetry: 1. Properly working devices

    Get PDF
    BACKGROUND: Active Magnetic Resonance Imaging implants are constructed as resonators tuned to the Larmor frequency of a magnetic resonance system with a specific field strength. The resonating circuit may be embedded into or added to the normal metallic implant structure. The resonators build inductively coupled wireless transmit and receive coils and can amplify the signal, normally decreased by eddy currents, inside metallic structures without affecting the rest of the spin ensemble. During magnetic resonance imaging the resonators generate heat, which is additional to the usual one described by the specific absorption rate. This induces temperature increases of the tissue around the circuit paths and inside the lumen of an active implant and may negatively influence patient safety. METHODS: This investigation provides an overview of the supplementary power absorbed by active implants with a cylindrical geometry, corresponding to vessel implants such as stents, stent grafts or vena cava filters. The knowledge of the overall absorbed power is used in a finite volume analysis to estimate temperature maps around different implant structures inside homogeneous tissue under worst-case assumptions. The "worst-case scenario" assumes thermal heat conduction without blood perfusion inside the tissue around the implant and mostly without any cooling due to blood flow inside vessels. RESULTS: The additional power loss of a resonator is proportional to the volume and the quality factor, as well as the field strength of the MRI system and the specific absorption rate of the applied sequence. For properly working devices the finite volume analysis showed only tolerable heating during MRI investigations in most cases. Only resonators transforming a few hundred mW into heat may reach temperature increases over 5 K. This requires resonators with volumes of several ten cubic centimeters, short inductor circuit paths with only a few 10 cm and a quality factor above ten. Using MR sequences, for which the MRI system manufacturer declares the highest specific absorption rate of 4 W/kg, vascular implants with a realistic construction, size and quality factor do not show temperature increases over a critical value of 5 K. CONCLUSION: The results show dangerous heating for the assumed "worst-case scenario" only for constructions not acceptable for vascular implants. Realistic devices are safe with respect to temperature increases. However, this investigation discusses only properly working devices. Ruptures or partial ruptures of the wires carrying the electric current of the resonance circuits or other defects can set up a power source inside an extremely small volume. The temperature maps around such possible "hot spots" should be analyzed in an additional investigation
    • …
    corecore