349 research outputs found

    Acoustic tweezer with complex boundary-free trapping and transport channel controlled by shadow waveguides.

    Get PDF
    Acoustic tweezers use ultrasound for contact-free, bio-compatible, and precise manipulation of particles from millimeter to submicrometer scale. In microfluidics, acoustic tweezers typically use an array of sources to create standing wave patterns that can trap and move objects in ways constrained by the limited complexity of the acoustic wave field. Here, we demonstrate spatially complex particle trapping and manipulation inside a boundary-free chamber using a single pair of sources and an engineered structure outside the chamber that we call a shadow waveguide. The shadow waveguide creates a tightly confined, spatially complex acoustic field inside the chamber without requiring any interior structure that would interfere with net flow or transport. Altering the input signals to the two sources creates trapped particle motion along an arbitrary path defined by the shadow waveguide. Particle trapping, particle manipulation and transport, and Thouless pumping are experimentally demonstrated

    Isolation of exosomes from whole blood by integrating acoustics and microfluidics

    Get PDF
    Exosomes are nanoscale extracellular vesicles that play an important role in many biological processes, including intercellular communications, antigen presentation, and the transport of proteins, RNA, and other molecules. Recently there has been significant interest in exosome-related fundamental research, seeking new exosome-based biomarkers for health monitoring and disease diagnoses. Here, we report a separation method based on acoustofluidics (i.e., the integration of acoustics and microfluidics) to isolate exosomes directly from whole blood in a label-free and contact-free manner. This acoustofluidic platform consists of two modules: a microscale cell-removal module that first removes larger blood components, followed by extracellular vesicle subgroup separation in the exosome-isolation module. In the cell-removal module, we demonstrate the isolation of 110-nm particles from a mixture of micro- and nanosized particles with a yield greater than 99%. In the exosome-isolation module, we isolate exosomes from an extracellular vesicle mixture with a purity of 98.4%. Integrating the two acoustofluidic modules onto a single chip, we isolated exosomes from whole blood with a blood cell removal rate of over 99.999%. With its ability to perform rapid, biocompatible, label-free, contact-free, and continuous-flow exosome isolation, the integrated acoustofluidic device offers a unique approach to investigate the role of exosomes in the onset and progression of human diseases with potential applications in health monitoring, medical diagnosis, targeted drug delivery, and personalized medicine. Keywords: extracellular vesicles; exosomes; blood-borne vesicles; surface acoustic waves; acoustic tweezersNational Science Foundation (U.S.) (Grant R01 HD086325)National Science Foundation (U.S.) (Grant IIP-1534645

    Acoustic separation of circulating tumor cells

    Get PDF
    Circulating tumor cells (CTCs) are important targets for cancer biology studies. To further elucidate the role of CTCs in cancer metastasis and prognosis, effective methods for isolating extremely rare tumor cells from peripheral blood must be developed. Acoustic-based methods, which are known to preserve the integrity, functionality, and viability of biological cells using label-free and contact-free sorting, have thus far not been successfully developed to isolate rare CTCs using clinical samples from cancer patients owing to technical constraints, insufficient throughput, and lack of long-term device stability. In this work, we demonstrate the development of an acoustic-based microfluidic device that is capable of high-throughput separation of CTCs from peripheral blood samples obtained from cancer patients. Our method uses tilted-angle standing surface acoustic waves. Parametric numerical simulations were performed to design optimum device geometry, tilt angle, and cell throughput that is more than 20 times higher than previously possible for such devices. We first validated the capability of this device by successfully separating low concentrations (~100 cells/mL) of a variety of cancer cells from cell culture lines from WBCs with a recovery rate better than 83%. We then demonstrated the isolation of CTCs in blood samples obtained from patients with breast cancer. Our acoustic-based separation method thus offers the potential to serve as an invaluable supplemental tool in cancer research, diagnostics, drug efficacy assessment, and therapeutics owing to its excellent biocompatibility, simple design, and label-free automated operation while offering the capability to isolate rare CTCs in a viable state.National Institutes of Health (U.S.) (Grant 1 R01 GM112048-01A1)National Institutes of Health (U.S.) (Grant 1R33EB019785-01)National Science Foundation (U.S.)Penn State Center for Nanoscale Science (Materials Research Science and Engineering Center Grant DMR-0820404)National Institutes of Health (U.S.) (Grant U01HL114476

    Cell separation using tilted-angle standing surface acoustic waves

    Get PDF
    Separation of cells is a critical process for studying cell properties, disease diagnostics, and therapeutics. Cell sorting by acoustic waves offers a means to separate cells on the basis of their size and physical properties in a label-free, contactless, and biocompatible manner. The separation sensitivity and efficiency of currently available acoustic-based approaches, however, are limited, thereby restricting their widespread application in research and health diagnostics. In this work, we introduce a unique configuration of tilted-angle standing surface acoustic waves (taSSAW), which are oriented at an optimally designed inclination to the flow direction in the microfluidic channel. We demonstrate that this design significantly improves the efficiency and sensitivity of acoustic separation techniques. To optimize our device design, we carried out systematic simulations of cell trajectories, matching closely with experimental results. Using numerically optimized design of taSSAW, we successfully separated 2- and 10-µm-diameter polystyrene beads with a separation efficiency of ~99%, and separated 7.3- and 9.9-µm-polystyrene beads with an efficiency of ~97%. We illustrate that taSSAW is capable of effectively separating particles–cells of approximately the same size and density but different compressibility. Finally, we demonstrate the effectiveness of the present technique for biological–biomedical applications by sorting MCF-7 human breast cancer cells from nonmalignant leukocytes, while preserving the integrity of the separated cells. The method introduced here thus offers a unique route for separating circulating tumor cells, and for label-free cell separation with potential applications in biological research, disease diagnostics, and clinical practice.National Institutes of Health (U.S.) (Grant U01HL114476)National Institutes of Health (U.S.) (New Innovator Award 1DP2OD007209-01)National Science Foundation (U.S.). Materials Research Science and Engineering Centers (Program) (Grant DMR-0820404

    Functional Liquid Metal Nanoparticles Produced by Liquid-Based Nebulization

    Get PDF
    Functional liquid metal nanoparticles (NPs), produced from eutectic alloys of gallium, promise new horizons in the fields of sensors, microfluidics, flexible electronics, catalysis, and biomedicine. Here, the development of a vapor cavity generating ultrasonic platform for nebulizing liquid metal within aqueous media for the one-step production of stable and functional liquid metal NPs is shown. The size distribution of the NPs is fully characterized and it is demonstrated that various macro and small molecules can also be grafted onto these liquid metal NPs during the liquid-based nebulization process. The cytotoxicity of the NPs grafted with different molecules is further explored. Moreover, it is shown that it is possible to control the thickness of the oxide layer on the produced NPs using electrochemistry that can be embedded within the platform. It is envisaged that this platform can be adapted as a cost-effective and versatile device for the rapid production of functional liquid metal NPs for future liquid metal-based optical, electronic, catalytic, and biomedical applications

    Dispersion tuning and route reconfiguration of acoustic waves in valley topological phononic crystals

    Get PDF
    The valley degree of freedom in crystals offers great potential for manipulating classical waves, however, few studies have investigated valley states with complex wavenumbers, valley states in graded systems, or dispersion tuning for valley states. Here, we present tunable valley phononic crystals (PCs) composed of hybrid channel-cavity cells with three tunable parameters. Our PCs support valley states and Dirac cones with complex wavenumbers. They can be configured to form chirped valley PCs in which edge modes are slowed to zero group velocity states, where the energy at different frequencies accumulates at different designated locations. They enable multiple functionalities, including tuning of dispersion relations for valley states, robust routing of surface acoustic waves, and spatial modulation of group velocities. This work may spark future investigations of topological states with complex wavenumbers in other classical systems, further study of topological states in graded materials, and the development of acoustic devices

    CBP loss cooperates with PTEN haploinsufficiency to drive prostate cancer: implications for epigenetic therapy

    Get PDF
    Despite the high incidence and mortality of prostate cancer, the etiology of this disease is not fully understood. In this study, we develop functional evidence for CBP and PTEN interaction in prostate cancer based on findings of their correlate expression in the human disease. Cbppc−/−;Ptenpc+/− mice exhibited higher cell proliferation in the prostate and an early onset of high-grade prostatic intraepithelial neoplasia. Levels of EZH2 methyltransferase were increased along with its Thr350 phosphorylation in both mouse Cbp−/−;Pten+/− and human prostate cancer cells. CBP loss and PTEN deficiency cooperated to trigger a switch from K27-acetylated histone H3 to K27-trimethylated bulk histones, in a manner associated with decreased expression of the growth inhibitory EZH2 target genes DAB2IP, p27KIP1 and p21CIP1. Conversely, treatment with the histone deacetylase inhibitor panobinostat reversed this switch, in a manner associated with tumor suppression in Cbppc−/−;Ptenpc+/− mice. Our findings show how CBP and PTEN interact to mediate tumor suppression in the prostate, establishing a central role for histone modification in the etiology of prostate cancer and providing a rationale for clinical evaluation of epigenetic targeted therapy in prostate cancer patients

    Performance of Monolayer Graphene Nanomechanical Resonators with Electrical Readout

    Full text link
    The enormous stiffness and low density of graphene make it an ideal material for nanoelectromechanical (NEMS) applications. We demonstrate fabrication and electrical readout of monolayer graphene resonators, and test their response to changes in mass and temperature. The devices show resonances in the MHz range. The strong dependence of the resonant frequency on applied gate voltage can be fit to a membrane model, which yields the mass density and built-in strain. Upon removal and addition of mass, we observe changes in both the density and the strain, indicating that adsorbates impart tension to the graphene. Upon cooling, the frequency increases; the shift rate can be used to measure the unusual negative thermal expansion coefficient of graphene. The quality factor increases with decreasing temperature, reaching ~10,000 at 5 K. By establishing many of the basic attributes of monolayer graphene resonators, these studies lay the groundwork for applications, including high-sensitivity mass detectors
    • …
    corecore