21 research outputs found

    Opportunities For The Transfer of Astronomical Technology to Medicine

    Get PDF
    There are many examples of technology transfer from astronomy to medicine, for example algorithms for reconstructing X-ray CT images were first developed for processing radio astronomy images. In more recent times, X-ray detectors developed for the Hubble Space Telescope have been used in a fine-needle breast biopsy system. Software originally developed to mosaic planetary images has been incorporated into a system for detecting breast cancer. Australia has expertise in the development of instrumentation for producing radio images from an array of radio telescopes and in multi-object fibre systems for capturing the spectra of hundreds of stellar objects simultaneously. Two possible applications of these Australian technologies are suggested that may merit further exploration. A meeting between interested parties is suggested to discuss future directions and funding

    Radiology of the Anatomical Compartments

    No full text

    Quantitative computed tomography bone mineral density measurements in irradiated and non-irradiated minipig alveolar bone: an experimental study.

    No full text
    Contains fulltext : 71287.pdf (publisher's version ) (Closed access)OBJECTIVE: The objective of this study was to analyse the effect of irradiation on bone mineral density (BMD). MATERIALS AND METHODS: All maxillary and mandibular pre-molars and molars of six minipigs were extracted. After a 3-month healing period, the maxilla and mandibles of three minipigs received three irradiation exposures at a total dose of 24 Gy. At 3 months after irradiation, quantitative computed tomography (QCT) was performed. As a reference, a calibration bone phantom with pre-determined BMD was attached to the head of the minipigs. The QCT data were imported into a software program to calculate the BMD of the alveolar bone and the calibration bone phantom. In order to compare BMD values of individual minipigs, the so-called bone mineral density quotient (BMDQ) was created, dividing the BMD value of the alveolar bone by the BMD value of the calibration bone phantom. RESULTS: Mean BMDQ values appeared to be higher in irradiated than in non-irradiated minipigs. However, the difference was not significant. In both irradiated and non-irradiated minipigs, the average mandibular BMDQ values were statistically significantly higher than the average maxillary BMDQ values (P=0.003). The P-values of the Student t-test, determining the irradiation effect, were 0.11 for maxillary, 0.14 for mandibular, and 0.07 for overall peri-implant BMDQ. P-values of the non-parametric Mann-Whitney test were all 0.05. CONCLUSION: It could be concluded that, 3 months after irradiation, the BMD of irradiated alveolar minipig bone was increased, when compared with non-irradiated alveolar minipig bone. However, the increase was not statistically significant
    corecore