2,738 research outputs found

    Payload/orbiter contamination control requirement study: Computer interface

    Get PDF
    The MSFC computer facilities, and future plans for them are described relative to characteristics of the various computers as to availability and suitability for processing the contamination program. A listing of the CDC 6000 series and UNIVAC 1108 characteristics is presented so that programming requirements can be compared directly and differences noted

    Payload/orbiter contamination control requirement study: Preliminary contamination mission support plan

    Get PDF
    Progress is reported on the mission support plan and those support activities envisioned to be applicable and necessary during premission and postmission phases of the Spacelab program. The purpose, role, and requirements of the contamination control operations for the first two missions of the Spacelab equipped Space Transportation System are discussed. The organization of the contamination control operation and its relationship to and interfaces with other mission support functions is also discussed. Some specific areas of contamination to be investigated are treated. They are: (1) windows and viewports, (2) experiment equipment, (3) thermal control surfaces, (4) the contaminant induced atmosphere (as differentiated from the normal ambient atmosphere at the orbit altitude), and (5) optical navigation instruments

    Payload/orbiter contamination control requirement study, volume 2, exhibit A

    Get PDF
    The computer printout data generated during the Payload/Orbiter Contamination Control Requirement Study are presented. The computer listings of the input surface data matrices, the viewfactor data matrices, and the geometric relationship data matrices for the three orbiter/spacelab configurations analyzed in this study are given. These configurations have been broken up into the geometrical surfaces and nodes necessary to define the principal critical surfaces whether they are contaminant sources, experimental surfaces, or operational surfaces. A numbering scheme was established based upon nodal numbers that relates the various spacelab surfaces to a specific surface material or function. This numbering system was developed for the spacelab configurations such that future extension to a surface mapping capability could be developed as required

    Payload/orbiter contamination control requirement study: Computer interface

    Get PDF
    A preliminary assessment of the computer interface requirements of the Spacelab configuration contamination computer model was conducted to determine the compatibility of the program, as presently formatted, with the computer facilities at MSFC. The necessary Spacelab model modifications are pointed out. The MSFC computer facilities and their future plans are described, and characteristics of the various computers as to availability and suitability for processing the contamination program are discussed. A listing of the CDC 6000 series and UNIVAC 1108 characteristics is presented so that programming requirements can be compared directly and differences noted

    Plasma Physics

    Get PDF
    Contains research objectives and reports on four research projects.U.S. Atomic Energy Commission (Contract AT(30- 1)- 1842)U.S. Air Force (Electronic Systems Division) under Contract AF 19(604)- 599

    Two photon annihilation of Kaluza-Klein dark matter

    Full text link
    We investigate the fermionic one-loop cross section for the two photon annihilation of Kaluza-Klein (KK) dark matter particles in a model of universal extra dimensions (UED). This process gives a nearly mono-energetic gamma-ray line with energy equal to the KK dark matter particle mass. We find that the cross section is large enough that if a continuum signature is detected, the energy distribution of gamma-rays should end at the particle mass with a peak that is visible for an energy resolution of the detector at the percent level. This would give an unmistakable signature of a dark matter origin of the gamma-rays, and a unique determination of the dark matter particle mass, which in the case studied should be around 800 GeV. Unlike the situation for supersymmetric models where the two-gamma peak may or may not be visible depending on parameters, this feature seems to be quite robust in UED models, and should be similar in other models where annihilation into fermions is not helicity suppressed. The observability of the signal still depends on largely unknown astrophysical parameters related to the structure of the dark matter halo. If the dark matter near the galactic center is adiabatically contracted by the central star cluster, or if the dark matter halo has substructure surviving tidal effects, prospects for detection look promising.Comment: 17 pages, 3 figures; slightly revised versio

    Anisotropy of dark matter annihilation with respect to the Galactic plane

    Full text link
    We describe the anisotropy of dark matter clump distribution caused by tidal destruction of clumps in the Galactic disk. A tidal destruction of clumps with orbit planes near the disk plane occurs more efficiently as compared with destruction of clumps at near-polar orbits. A corresponding annihilation of dark matter particles in small-scale clumps produces the anisotropic gamma-ray signal with respect to the Galactic disk. This anisotropy is rather small, 9%, and superimposed on that due to off-centering position of the Sun in the Galaxy. The anisotropy of annihilation signal with respect to the Galactic disk provides a possibility to discriminate dark matter annihilation from the diffuse gamma-ray backgrounds of other origin.Comment: Accepted for publication in JCAP (minor changes

    An internet-based intervention with brief nurse support to manage obesity in primary care (POWeR+): a pragmatic, parallel-group, randomised controlled trial

    Get PDF
    Background The obesity epidemic has major public health consequences. Expert dietetic and behavioural counselling with intensive follow-up is effective, but resource requirements severely restrict widespread implementation in primary care, where most patients are managed. We aimed to estimate the effectiveness and cost-effectiveness of an internet-based behavioural intervention (POWeR+) combined with brief practice nurse support in primary care. Methods We did this pragmatic, parallel-group, randomised controlled trial at 56 primary care practices in central and south England. Eligible adults aged 18 years or older with a BMI of 30 kg/m2 or more (or ≥28 kg/m2 with hypertension, hypercholesterolaemia, or diabetes) registered online with POWeR+—a 24 session, web-based, weight management intervention lasting 6 months. After registration, the website automatically randomly assigned patients (1:1:1), via computer-generated random numbers, to receive evidence-based dietetic advice to swap foods for similar, but healthier, choices and increase fruit and vegetable intake, in addition to 6 monthly nurse follow-up (control group); web-based intervention and face-to-face nurse support (POWeR+Face-to-face [POWeR+F]; up to seven nurse contacts over 6 months); or web-based intervention and remote nurse support (POWeR+Remote [POWeR+R]; up to five emails or brief phone calls over 6 months). Participants and investigators were masked to group allocation at the point of randomisation; masking of participants was not possible after randomisation. The primary outcome was weight loss averaged over 12 months. We did a secondary analysis of weight to measure maintenance of 5% weight loss at months 6 and 12. We modelled the cost-effectiveness of each intervention. We did analysis by intention to treat, with multiple imputation for missing data. This trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN21244703. Findings Between Jan 30, 2013, and March 20, 2014, 818 participants were randomly assigned to the control group (n=279), the POWeR+F group (n=269), or the POWeR+R group (n=270). Weight loss averaged over 12 months was recorded in 666 (81%) participants. The control group lost almost 3 kg over 12 months (crude mean weight: baseline 104·38 kg [SD 21·11; n=279], 6 months 101·91 kg [19·35; n=136], 12 months 101·74 kg [19·57; n=227]). The primary imputed analysis showed that compared with the control group, patients in the POWeR+F group achieved an additional weight reduction of 1·5 kg (95% CI 0·6–2·4; p=0·001) averaged over 12 months, and patients in the POWeR+R group achieved an additional 1·3 kg (0·34–2·2; p=0·007). 21% of patients in the control group had maintained a clinically important 5% weight reduction at month 12, compared with 29% of patients in the POWeR+F group (risk ratio 1·56, 0·96–2·51; p=0·070) and 32% of patients in the POWeR+R group (1·82, 1·31–2·74; p=0·004). The incremental overall cost to the health service per kg weight lost with the POWeR+ interventions versus the control strategy was £18 (95% CI −129 to 195) for POWeR+F and –£25 (−268 to 157) for POWeR+R; the probability of being cost-effective at a threshold of £100 per kg lost was 88% and 98%, respectively. No adverse events were reported. Interpretation Weight loss can be maintained in some individuals by use of novel written material with occasional brief nurse follow-up. However, more people can maintain clinically important weight reductions with a web-based behavioural program and brief remote follow-up, with no increase in health service costs. Future research should assess the extent to which clinically important weight loss can be maintained beyond 1 year

    Results from PAMELA, ATIC and FERMI : Pulsars or Dark Matter ?

    Full text link
    It is well known that the dark matter dominates the dynamics of galaxies and clusters of galaxies. Its constituents remain a mystery despite an assiduous search for them over the past three decades. Recent results from the satellite-based PAMELA experiment detect an excess in the positron fraction at energies between 10-100 GeV in the secondary cosmic ray spectrum. Other experiments namely ATIC, HESS and FERMI show an excess in the total electron (\ps + \el) spectrum for energies greater 100 GeV. These excesses in the positron fraction as well as the electron spectrum could arise in local astrophysical processes like pulsars, or can be attributed to the annihilation of the dark matter particles. The second possibility gives clues to the possible candidates for the dark matter in galaxies and other astrophysical systems. In this article, we give a report of these exciting developments.Comment: 27 Pages, extensively revised and significantly extended, to appear in Pramana as topical revie

    Results from a pilot plant using un-promoted potassium carbonate for carbon capture

    Get PDF
    A pilot plant facility has been designed and built to trial potassium carbonate solvent technology for carbon capture under a range of conditions. The rig is capable of capturing 4 - 10 kg/hr of CO2 from 30 - 55 kg/hr of an air-CO2 mixture, with different packings. A series of trials have been completed with a range of solvent concentrations from 20 wt% to 30 wt% potassium carbonate. The experimental holdup, solvent loading and absorber temperatures have been matched with rate-based simulations in Aspen Plus® software
    corecore