31 research outputs found

    Исследование влияния давления в реакторах на процесс каталитического риформинга бензинов

    Get PDF
    Freeman-Sheldon syndrome is defined as a combination of microstomia, deep set eyes, small palpebral fissures, arthrogryposis with ulnar deviation of the hand, talipes equinovarus and generalized muscular hypertension. Respiratory and swallowing problems are frequently encountered in these patients due to small orifices of mouth and nose. Obstruction of the upper airway tract resulting in tracheostomy has only been described twice. The described child manifested the typical dysmorphic features of Freeman-Sheldon syndrome and suffered from serious respiratory distress and swallowing difficulties from birth. The boy died at the age of 7 months after accidental decannulation of the tracheostoma during sleep. He did not show anatomical or histopathological abnormalities in the pharyngeal, laryngeal or tracheal regions. We assume that the only explanation of the repeated obstructive episodes is a functional muscular obstruction. Copyright © 2002 S. Karger AG, Basel

    Human cytomegalovirus immediate-early 1 protein rewires upstream STAT3 to downstream STAT1 signaling switching an IL6-type to an IFNγ-like response

    Get PDF
    MN and CP were supported by the Wellcome Trust (www.wellcome.ac.uk) Institutional Strategic Support Fund and CP was supported by the Deutsche Forschungsgemeinschaft (PA 815/2-1; www.dfg.de).The human cytomegalovirus (hCMV) major immediate-early 1 protein (IE1) is best known for activating transcription to facilitate viral replication. Here we present transcriptome data indicating that IE1 is as significant a repressor as it is an activator of host gene expression. Human cells induced to express IE1 exhibit global repression of IL6- and oncostatin M-responsive STAT3 target genes. This repression is followed by STAT1 phosphorylation and activation of STAT1 target genes normally induced by IFNγ. The observed repression and subsequent activation are both mediated through the same region (amino acids 410 to 445) in the C-terminal domain of IE1, and this region serves as a binding site for STAT3. Depletion of STAT3 phenocopies the STAT1-dependent IFNγ-like response to IE1. In contrast, depletion of the IL6 receptor (IL6ST) or the STAT kinase JAK1 prevents this response. Accordingly, treatment with IL6 leads to prolonged STAT1 instead of STAT3 activation in wild-type IE1 expressing cells, but not in cells expressing a mutant protein (IE1dl410-420) deficient for STAT3 binding. A very similar STAT1-directed response to IL6 is also present in cells infected with a wild-type or revertant hCMV, but not an IE1dl410-420 mutant virus, and this response results in restricted viral replication. We conclude that IE1 is sufficient and necessary to rewire upstream IL6-type to downstream IFNγ-like signaling, two pathways linked to opposing actions, resulting in repressed STAT3- and activated STAT1-responsive genes. These findings relate transcriptional repressor and activator functions of IE1 and suggest unexpected outcomes relevant to viral pathogenesis in response to cytokines or growth factors that signal through the IL6ST-JAK1-STAT3 axis in hCMV-infected cells. Our results also reveal that IE1, a protein considered to be a key activator of the hCMV productive cycle, has an unanticipated role in tempering viral replication.Publisher PDFPeer reviewe

    Caustic injury of the oesophagus. Sixteen years experience, and introduction of a new model oesophageal stent

    No full text
    Caustic ingestion can lead to oesophageal stenosis. We studied 251 patients, 205 of whom were children, in a sixteen-year period. Seventeen patients, of whom one was an adult, acquired deep burns in the oesophagus which had to be treated, to prevent the development of oesophageal strictures. These patients were treated with long-term stenting of the oesophagus with specially designed, silicone rubber stents, impregnated with silicone oil 20 cS, designed by one of us (R.N.P.B.) as the only treatment. Of all models, the twin-tube dilator was the most satisfactory. No corticosteroids were administered. Only one patient developed a mild stenosis. It is therefore our opinion that, when life-saving operations are not indicated, twin-tube stenting of the oesophagus is helpful in treating caustic lesions of the oesophagus and will prevent stricture formation. Corticosteroids were not given in this series, and should be abandoned in the treatment of caustic lesion

    Anatomical In Vitro Investigations of the Pediatric Larynx: A Call for Manufacturer Redesign of Tracheal Tube Cuff Location and Perhaps a Call to Reconsider the Use of Uncuffed Tracheal Tubes

    No full text
    BACKGROUND: Some in vivo studies question the traditional funnel-shaped infant larynx; further anatomic examinations were warranted. Examination of fixative free fresh autopsy laryngeal and upper tracheal specimens and multiple measurements was needed to determine consistency between current tracheal tube designs and anatomic observations. METHODS: Larynges from 19 males and 11 females (Caucasian term newborn to 126 months) were examined by the same forensic pathologist. Measurements included anterior/posterior (A/P) and transverse (T) diameters of the cricoid outlet (CO), interarytenoid diameter (IAD), cricothyroid membrane (CTM), distance from the vocal cords (VC) to CO (VC-CO), and calibration of the larynx lumen with uncuffed tracheal tubes as measuring rods. Assessment of safe tracheal tube placement was assessed using manufacturer recommended cuffed Microcuff (Kimberly-Clark, Koblenz, Germany) tubes. RESULTS: In 77% (95% confidence interval [CI], 58-90) of specimens, the proximal end of the cuff was within the CO and in 23% even with or close to the CO. The VC-CO varied from 9.1 to 13.17 mm in infants, 11.55 to 15.17 mm in toddlers, and 13.19 to 18.34 mm in children. The A-P/T ratio of the CO was nearly 0.99 in most larynges; the IAD was greater than CO in all specimens. The CTM could be minimally distended in all specimens. CONCLUSIONS: First, despite being marketed as a safer tracheal tube design, the proximal end of the Microcuff cuff rested within or close to the cricoid cartilage theoretically increasing potential cuff-induced injury when using the VC markings for positioning. Our data suggest that the optimal cuff free distance (VC-CO) would be similar to 13.5 mm for a Microcuff internal diameter (ID) size 3.0, similar to 15 mm for size 3.5, and similar to 16 to 19 mm for greater sizes. Second, the CO was virtually circular in all specimens, suggesting that appropriately sized uncuffed tubes should provide an adequate seal in most neonates and toddlers, thus avoiding the potential for cuff-related necrosis injury. Third, the IAD was always greater than CO confirming that the narrowest point of the infant larynx is the nondistensible cricoid cartilage and not the easily distended glottis. Fourth, appropriately sized Microcuff tubes with the cuff deflated completely filled the lumen of the CO and proximal trachea in all specimens. Our data suggest the need for all manufacturers to further evaluate tracheal tube cuff locations and lengths in relation to the VC safe insertion markings, particularly for neonates and toddlers. Fifth, the CTM is minimally distensible, thus having important implications for emergency surgical airway access with most currently available emergency airway devices

    Scanning electron-microscopic evaluation of cuff shoulders in pediatric tracheal tubes

    Full text link
    BACKGROUND: Technical and conceptual shortcomings of cuffed pediatric tracheal tubes have been pointed out in the past, all representing a potential risk for mucosal damage of the pediatric airway. In this study, cuffed pediatric tracheal tubes from different manufacturers were investigated with regard to the cuff shoulder design using scanning electron microscopy (SEM). METHODS: Cuffed pediatric tracheal tubes with the smallest internal diameter available were ordered from five manufacturers. SEM scans were performed from the tube shaft - cuff shoulder - tube cuff assembly and from the cuff shoulder alone. Each investigation was repeated in four samples of each tube brand. In addition, thickness of cuff membrane was measured. RESULTS: Major differences were found among the cuff shoulders investigated ranging from smooth transitions, softened borders to very sharp steps. There was also considerable difference in the thickness among the cuff membranes between the different tube brands ranging from 18 microm in polyurethane cuffs up to 90 microm in polyvinylchloride cuffs. CONCLUSIONS: Because the gap between the outer tracheal tube and the internal mucosal layer of the pediatric airway is often very narrow, some of the observed irregularities have the potential to injure the airway mucosa in pediatric patients, particularly during long-term use and firm fit of the tracheal tube in the airway. As cuffed tubes are increasingly used in small children, the observed irregularities in some tracheal tube brands may need to be improved and their safety should be proved by the manufacturers
    corecore