1,315 research outputs found
COMPLIANCE TESTING OF IOWA’S SKID-MOUNTED SIGN DEVICE
A wide variety of traffic control devices are used in work zones, some of which are nont ormally found on the roadside or in the traveled way outsideofthe work zones. These devices are used to enhance the safety of the work zones by controlling the traffic through these areas. Due to the placement of the traffic control devices, the devices themselves may be potentially hazardous to both workers and errant vehicles. The impact performance of many work zone traffic control devices is mainly unknown and to date limited crash testing has been conducted under the criteria of National Cooperative Highway Research Program (NCHRP) Report No. 350, Recommended Procedures for the Safety Performance Evaluation of Highway Features.
The objective of the study was to evaluatethe safety performance of existing skid-mounted sign supports through full- scale crash testing. Two full-scale crash tests were conducted on skid-mounted sign supports to determine their safety performance according to the Test Level 3 (TL-3) criteria set forth in the NCHRP Report No. 350. The safety performancevaluations indicate that these skid-mounted sign supports did not perform satisfactorily in the full-scale crash tests. The results of the crash tests were documented, and conclusions and recommendations pertaining tothe safety performance of the existing work zone traffic control devices were made
A spatially resolved optical emission sensor for plasma etch monitoring
A spatially resolved optical emission spectroscopy sensor has been developed, and the resulting reconstructed radial emission profiles from an ArI and ArII line compare well with Ar sputter etch uniformity profiles. The new sensor collects light from a wedge shaped field of view, and is rotated around a single collection point in order to observe the entire plasma through a relatively small viewpoint. © 1997 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/71036/2/APPLAB-71-11-1467-1.pd
AART-BC: a sensor system for monitoring Assistive Technology use beyond the clinic
A wide range of assistive and rehabilitative technologies (ART) are available to assist with mobility and upper limb function. However, anecdotal evidence suggests many of the devices prescribed, or purchased, are either poorly used, or rejected entirely. This situation is costly, both for the healthcare provider and the user, and may be leading to secondary consequences, such as falls and/or social isolation. This paper reports on the development and initial feasibility testing of a system for monitoring when and how assistive devices are used outside of the clinic setting, and feeding this information to the device user themselves and/or prescribing clinician (where appropriate). Illustrative data from multiple time-synchronized device and body worn sensors are presented on a wheelchair user and a user of a “rollator” walking frame, moving along a walkway. Observation of the sensor data in both cases showed characteristic signatures corresponding to individual “pushes”. In parallel with this work, other project partners are exploring clinician and patient data requirements, as well we sensor set acceptability The initial results highlight the potential for the approach and demonstrate the need for further work to reduce and optimize the sensor set
SAFETY PERFORMANCE EVALUATION OF MICHIGAN’S 4X5 PORTABLE SIGN SUPPORT
A wide variety of traffic controlling devices are used in work zones, some of which are not normally found on the roadside or in the traveled way outside of the work zones. These devices are used to enhance the safety of the work zones by controlling the traffic through these areas. Due to the placement of the traffic control devices, the devices themselves may be potentially hazardous to both workers and errant vehicles. The impact performance of many work-zone traffic control devices is mainly unknown and to date limited crash testing has been conducted, under the criteria of National Cooperative Highway Research Program (NCHRP) Report No. 350, Recommended Procedures for the Safety Performance Evaluation of Highway Features.
The objective of the study was to evaluate the safety performance of Michigan’s existing work-zone traffic control device through full-scale crash testing. A total of two full-scale crash tests were conducted on one 4-ft by 5-ft portable tall-mounted, rigid rectangular-shaped plywood panel sign support to determine its safety performance according to the Test Level 3 (TL-3) criteria set forth in the NCHRP Report No. 350. Neither of impacts on the tall-mounted, rigid panel sign supports resulted in acceptable safety performances. Following the analysis of these crash tests as well as the test results from other testing programs, it has been found that slight variations in design features of the work-zone traffic control devices can lead to very different performance results. Therefore, extreme care should be taken in applying crash test results from one work-zone traffic control device to similar work- zone traffic control devices with slight variations. The results of the crash tests were documented, and conclusions and recommendations pertaining to the safety performance of the existing work-zone traffic control devices were made
Validation of plaster endocast morphology through 3D CT image analysis
A crucial component of research on brain evolution has been the comparison of fossil endocranial surfaces with modern human and primate endocrania. The latter have generally been obtained by creating endocasts out of rubber latex shells filled with plaster. The extent to which the method of production introduces errors in endocast replicas is unknown. We demonstrate a powerful method of comparing complex shapes in 3-dimensions (3D) that is broadly applicable to a wide range of paleoanthropological questions. Pairs of virtual endocasts (VEs) created from high-resolution CT scans of corresponding latex/plaster endocasts and their associated crania were rigidly registered (aligned) in 3D space for two Homo sapiens and two Pan troglodytes specimens. Distances between each cranial VE and its corresponding latex/plaster VE were then mapped on a voxel-by-voxel basis. The results show that between 79.7% and 91.0% of the voxels in the four latex/plaster VEs are within 2 mm of their corresponding cranial VEs surfaces. The average error is relatively small, and variation in the pattern of error across the surfaces appears to be generally random overall. However, inferior areas around the cranial base and the temporal poles were somewhat overestimated in both human and chimpanzee specimens, and the area overlaying Broca's area in humans was somewhat underestimated. This study gives an idea of the size of possible error inherent in latex/plaster endocasts, indicating the level of confidence we can have with studies relying on comparisons between them and, e.g., hominid fossil endocasts. Am J Phys Anthropol, 2007. © 2006 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/55857/1/20499_ftp.pd
Boundary Effects on the Determination of Metamaterial Parameters from Normal Incidence Reflection and Transmission Measurements
A method is described for the determination of the effective electromagnetic
parameters of a metamaterial based only on external measurements or
simulations, taking boundary effects at the interfaces between a conventional
material and metamaterial into account. Plane-wave reflection and transmission
coefficients at the interfaces are regarded as additional unknowns to be
determined, rather than explicitly dependent on the material parameters. Our
technique is thus analogous to the line-reflect-line (LRL) calibration method
in microwave measurements. The refractive index can be determined from
S-parameters for two samples of different thickness. The effective wave
impedance requires the additional assumption that generalized sheet transition
conditions (GSTCs) account for the boundary effects. Expressions for the bulk
permittivity and permeability then follow easily. Our method is validated by
comparison with the results using the Nicolson-Ross-Weir (NRW) for determining
properties of an ordinary material measured in a coaxial line. Utilizing
S-parameters obtained from 3-D full wave simulations, we test the method on
magnetodielectric metamaterials. We compare the results from our method and the
conventional one that does not consider boundary effects. Moreover, it is shown
that results from our method are consistent under changes in reference plane
location, whereas the results from other methods are not.Comment: 16 pages, 16 figures. Submitted to IEEE Transactions on Antennas and
Propagatio
COMPLIANCE TESTING OF IOWA’S SKID-MOUNTED SIGN DEVICE
A wide variety of traffic control devices are used in work zones, some of which are nont ormally found on the roadside or in the traveled way outsideofthe work zones. These devices are used to enhance the safety of the work zones by controlling the traffic through these areas. Due to the placement of the traffic control devices, the devices themselves may be potentially hazardous to both workers and errant vehicles. The impact performance of many work zone traffic control devices is mainly unknown and to date limited crash testing has been conducted under the criteria of National Cooperative Highway Research Program (NCHRP) Report No. 350, Recommended Procedures for the Safety Performance Evaluation of Highway Features.
The objective of the study was to evaluatethe safety performance of existing skid-mounted sign supports through full- scale crash testing. Two full-scale crash tests were conducted on skid-mounted sign supports to determine their safety performance according to the Test Level 3 (TL-3) criteria set forth in the NCHRP Report No. 350. The safety performancevaluations indicate that these skid-mounted sign supports did not perform satisfactorily in the full-scale crash tests. The results of the crash tests were documented, and conclusions and recommendations pertaining tothe safety performance of the existing work zone traffic control devices were made
Effects of deceptive self-reports of quitting on the results of treatment trials for smoking: A quantitative assessment
Problems with self-report measures for smoking motivate the use of biochemical tests in treatment trials for smoking. These biochemical tests, unfortunately, are not perfect. In this paper, we present an algebraic model of bias in treatment trials for smoking. Bias is expressed in terms of the deception rate among continued smokers in a control group, the relative deception rate among continued smokers in an experimental group, and the sensitivity and specificity of a biochemical test which may be used either to confirm self-reports of,quitting or to replace self-report entirely. For given test specificity and sensitivity, the mode) defines deception rates for which different biochemical testing strategies are preferred. The model is presented in the context of current knowledge on the phenomenon of deception among adult smokers. The paper concludes that better judgements regarding the role of biochemical tests in treatment trials for smoking require more precise information regarding the magnitude and determinants of deception.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/28158/1/0000610.pd
- …