47 research outputs found

    Construction of the Soudan 2 detector

    Get PDF
    Progress in the construction of the Soudan 2 nucleon decay detector which is being built at the Soudan iron mine in Minnesota is discussed. The expected event rate and characteristics of low energy neutrino events, muon events, multiple muon events, and other cosmic ray phenomena are discussed

    Spatial Resolution Attainable with Cathode Strip Chambers at the Trigger Level

    Get PDF
    A simple network of comparators applied to the strip signals of a cathode strip chamber allows quick hit localization to within a halfstrip width, or +/- a quarter-strip. A six-plane chamber with 6.4 mm wide strips was tested in a high-energy muon beam. The chamber was placed behind a 30 cm thick iron block. We show that patterns of hits localized to within a halfstrip allowed us to identify 300 GeV/c muon tracks with 99% probability and 0.7 mm spatial resolution in the presence of muon bremsstrahlung radiation. This technique of finding muon tracks will be used in the cathode strip chambers of the CMS Endcap Muon System

    Risk of upper gastrointestinal bleeding and perforation associated with low-dose aspirin as plain and enteric-coated formulations

    Get PDF
    BACKGROUND: The use of low-dose aspirin has been reported to be associated with an increased risk of upper gastrointestinal complications (UGIC). The coating of aspirin has been proposed as an approach to reduce such a risk. To test this hypothesis, we carried out a population based case-control study. METHODS: We identified incident cases of UGIC (bleeding or perforation) aged 40 to 79 years between April 1993 to October 1998 registered in the General Practice Research Database. Controls were selected randomly from the source population. Adjusted estimates of relative risk (RR) associated with current use of aspirin as compared to non use were computed using unconditional logistic regression. RESULTS: We identified 2,105 cases of UGIC and selected 11,500 controls. Among them, 287 (13.6%) cases and 837 (7.3%) controls were exposed to aspirin, resulting in an adjusted RR of 2.0 (1.7-2.3). No clear dose-effect was found within the range of 75-300 mg. The RR associated with enteric-coated formulations (2.3, 1.6-3.2) was similar to the one of plain aspirin (1.9, 1.6-2.3), and no difference was observed depending on the site. The first two months of treatment was the period of greater risk (RR= 4.5, 2.9-7.1). The concomitant use of aspirin with high-dose NSAIDs greatly increased the risk of UGIC (13.3, 8.5-20.9) while no interaction was apparent with low-medium doses (2.2, 1.0-4.6). CONCLUSIONS: Low-dose aspirin increases by twofold the risk of UGIC in the general population and its coating does not modify the effect. Concomitant use of low-dose aspirin and NSAIDs at high doses put patients at a specially high risk of UGIC

    Measurement of the transverse spin dependence of the pp total cross section in the 1-3 GeV/c region

    Full text link
    The pp total cross section difference between pure transverse spin states was measured in the laboratory momentum range 1-3 GeV/c. Significant differences were found and these differences show striking energy dependence. This structure is in disagreement with the predictions of simple exchange models.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/22658/1/0000209.pd
    corecore