41 research outputs found

    Electrocardiographic Patterns of Ventricular Arrhythmias in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy

    Get PDF
    Ventricular arrhythmias in patients with ARVD/C are common. Differentiation between idiopathic ventricular tachycardia and arrhythmogenic right ventricular dysplasia is of utmost importance. Baseline sinus rhythm electrocardiography as well as electrocardiographic differences during ventricular arrhythmias (VT or PVCs) can be helpful in differentiating the two disease states. The pathological fibrofatty myocyte replacement in ARVD/C as well as ventricular arrhythmia origin are likely responsible for these differences

    Bidirectional ventricular tachycardia in cardiac sarcoidosis.

    Get PDF
    A 73-year-old man with history of pulmonary sarcoidosis was found to have runs of non-sustained bidirectional ventricular tachycardia (BVT) with two different QRS morphologies on a Holter monitor. Cardiac magnetic resonance delayed gadolinium imaging revealed a region of patchy mid-myocardial enhancement within the left ventricular basal inferolateral myocardium. An 18-fluorodeoxyglucose positron emission tomography (FDG-PET) showed increased uptake in the same area, consistent with active sarcoid, with no septal involvement. Follow-up FDG-PET one year later showed disease progression with new septal involvement. Cardiac sarcoidosis, characterized by myocardial inflammation and interstitial fibrosis that can lead to conduction system disturbance and macro re-entrant arrhythmias, should be considered in differential diagnosis of BVT. BVT may indicate septal involvement with sarcoidosis before the lesions are large enough to be detected radiologically

    Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study).

    Get PDF
    BackgroundTransseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access.Methods and resultsIn this prospective, single-blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK-1) transseptal needle. In an intention-to-treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P = 0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P < 0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P < 0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]).ConclusionsUse of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings

    Closure of a Para-valvular Aortic Leak: with the Use of 2 AMPLATZER Devices and Real-Time 2− and 3-Dimensional Transesophageal Echocardiography

    Get PDF
    Paravalvular leaks are well-recognized sequelae of mechanical aortic valve implantation. Clinical manifestations include hemolysis, arrhythmias, and congestive heart failure. Frequently, patients who receive mechanical aortic valves are poor candidates for repeat valve surgery, and the reoperative mortality rate is high. Percutaneous intervention has recently become an alternative to surgery in selected patients. Herein, we describe the percutaneous closure of an aortic paravalvular leak in a 45-year-old man who had undergone 2 aortic valve replacements with mechanical valves. The patient, who was at high surgical risk due to comorbidities, underwent the implantation of 2 AMPLATZER devices with the use of real-time 2- and 3-dimensional transesophageal echocardiography. The early outcome of the procedure was favorable and without sequelae. To our knowledge, this is the 1st report of the closing of an aortic paravalvular leak with the use of 2 closure devices and real-time echocardiographic guidance
    corecore