41 research outputs found
Electrocardiographic Patterns of Ventricular Arrhythmias in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy
Ventricular arrhythmias in patients with ARVD/C are common. Differentiation between idiopathic ventricular tachycardia and arrhythmogenic right ventricular dysplasia is of utmost importance. Baseline sinus rhythm electrocardiography as well as electrocardiographic differences during ventricular arrhythmias (VT or PVCs) can be helpful in differentiating the two disease states. The pathological fibrofatty myocyte replacement in ARVD/C as well as ventricular arrhythmia origin are likely responsible for these differences
Bidirectional ventricular tachycardia in cardiac sarcoidosis.
A 73-year-old man with history of pulmonary sarcoidosis was found to have runs of non-sustained bidirectional ventricular tachycardia (BVT) with two different QRS morphologies on a Holter monitor. Cardiac magnetic resonance delayed gadolinium imaging revealed a region of patchy mid-myocardial enhancement within the left ventricular basal inferolateral myocardium. An 18-fluorodeoxyglucose positron emission tomography (FDG-PET) showed increased uptake in the same area, consistent with active sarcoid, with no septal involvement. Follow-up FDG-PET one year later showed disease progression with new septal involvement. Cardiac sarcoidosis, characterized by myocardial inflammation and interstitial fibrosis that can lead to conduction system disturbance and macro re-entrant arrhythmias, should be considered in differential diagnosis of BVT. BVT may indicate septal involvement with sarcoidosis before the lesions are large enough to be detected radiologically
Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study).
BackgroundTransseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access.Methods and resultsIn this prospective, single-blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK-1) transseptal needle. In an intention-to-treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P = 0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P < 0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P < 0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]).ConclusionsUse of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings
Recommended from our members
Physician Accuracy in Interpreting Potential STâSegment Elevation Myocardial Infarction Electrocardiograms
Background: With adoption of telemedicine, physicians are increasingly asked to diagnose STâsegment elevation myocardial infarctions (STEMIs) based on electrocardiograms (ECGs) with minimal associated clinical information. We sought to determine physicians' diagnostic agreement and accuracy when interpreting potential STEMI ECGs. Methods and Results: A crossâsectional survey was performed consisting of 36 deidentified ECGs that had previously resulted in putative STEMI diagnoses. Emergency physicians, cardiologists, and interventional cardiologists participated in the survey. For each ECG, physicians were asked, âbased on the ECG above, is there a blocked coronary artery present causing a STEMI?â The reference standard for ascertaining the STEMI diagnosis was subsequent emergent coronary arteriography. Responses were analyzed with generalized estimating equations to account for nested and repeated measures. One hundred twentyâfour physicians interpreted a total of 4392 ECGs. Among all physicians, interreader agreement (kappa) for ECG interpretation was 0.33, reflecting poor agreement. The sensitivity to identify âtrueâ STEMIs was 65% (95% CI: 63 to 67) and the specificity was 79% (95% CI: 77 to 81). There was a 6% increase in the odds of accurate ECG interpretation for every 5 years of experience since medical school graduation (OR 1.06, 95% CI: 1.02 to 1.10, P=0.01). After adjusting for experience, there was no significant difference in the odds of accurate interpretation by specialtyâEmergency Medicine (reference), General Cardiology (AOR 0.97, 95% CI: 0.79 to 1.2, P=0.80), or Interventional Cardiology physicians (AOR 1.24, 95% CI: 0.93 to 1.7, P=0.15). Conclusions: There is significant physician disagreement in interpreting ECGs with features concerning for STEMI. Such ECGs lack the necessary sensitivity and specificity to act as a suitable âstandâaloneâ diagnostic test
Recommended from our members
Bidirectional ventricular tachycardia in cardiac sarcoidosis.
A 73-year-old man with history of pulmonary sarcoidosis was found to have runs of non-sustained bidirectional ventricular tachycardia (BVT) with two different QRS morphologies on a Holter monitor. Cardiac magnetic resonance delayed gadolinium imaging revealed a region of patchy mid-myocardial enhancement within the left ventricular basal inferolateral myocardium. An 18-fluorodeoxyglucose positron emission tomography (FDG-PET) showed increased uptake in the same area, consistent with active sarcoid, with no septal involvement. Follow-up FDG-PET one year later showed disease progression with new septal involvement. Cardiac sarcoidosis, characterized by myocardial inflammation and interstitial fibrosis that can lead to conduction system disturbance and macro re-entrant arrhythmias, should be considered in differential diagnosis of BVT. BVT may indicate septal involvement with sarcoidosis before the lesions are large enough to be detected radiologically
Closure of a Para-valvular Aortic Leak: with the Use of 2 AMPLATZER Devices and Real-Time 2â and 3-Dimensional Transesophageal Echocardiography
Paravalvular leaks are well-recognized sequelae of mechanical aortic valve implantation. Clinical manifestations include hemolysis, arrhythmias, and congestive heart failure. Frequently, patients who receive mechanical aortic valves are poor candidates for repeat valve surgery, and the reoperative mortality rate is high. Percutaneous intervention has recently become an alternative to surgery in selected patients. Herein, we describe the percutaneous closure of an aortic paravalvular leak in a 45-year-old man who had undergone 2 aortic valve replacements with mechanical valves. The patient, who was at high surgical risk due to comorbidities, underwent the implantation of 2 AMPLATZER devices with the use of real-time 2- and 3-dimensional transesophageal echocardiography. The early outcome of the procedure was favorable and without sequelae. To our knowledge, this is the 1st report of the closing of an aortic paravalvular leak with the use of 2 closure devices and real-time echocardiographic guidance