22,775 research outputs found

    Sapphire planar waveguides fabricated by H+ ion beam implantation

    Get PDF
    1.1-MeV proton-implanted sapphire waveguides are investigated for the first time. Optical measurements show that the planar waveguides support low-order transverse-mode propagation with good guiding properties without the need to anneal the samples

    Na+-H+ exchange activity in brush-border membrane vesicles isolated from chick small intestine

    Get PDF
    This study was undertaken to investigate the presence of a Na+{single bond}H+ antiporter in brush-border membrane vesicles (BBMV) isolated from chick small intestine. An outwardly directed proton gradient (pH 5.5 inside, 7.5 outside) stimulated Na+ uptake into BBMV and resulted in a transient accumulation. No accumulation was observed in the absence of a proton gradient. Voltage clamping the membrane with K+ and valinomycin decreased the Na+ overshoot. Amiloride inhibited pH gradient-driven Na+ uptake in a dose-dependent manner with an IC50 of 44 μM. The relationship between pH gradient-driven Na+ uptake and external Na+ concentration followed simple, saturating Michaelis-Menten kinetics. Eadie-Hofstee analysis of the pH gradient-driven Na+ uptake indicated a single transport system with a Vmax of 33 nmol/mg protein per 15 s and a Km for Na+ of 12 mM. The initial rate of pH-driven Na+ uptake increased as the intravesicular pH decreased, with a Hill coefficient close to 1. These findings indicate that BBMV isolated from chicken small intestine posses a Na+{single bond}H+ exchanger. This exchanger does not appear to be the one involved in cell pH regulation.Dirección General de Investigaciones Científicas y Técnicas PB89-061

    Comment on "Secure direct communication with a quantum one-time pad"

    Full text link
    In the paper [Phys. Rev. A \textbf{69}, 052319 (2004)], a quantum direct communication protocol is proposed which is claimed to be unconditionally secure even for the case of a noisy channel. We show that this is not the case by giving an undetectable attack scheme

    Variability in Hoffmann and tendon reflexes in healthy male subjects

    Get PDF
    There is a time dependent decrease in amplitude of H- and T-reflexes during Zero-G exposure and subsequently an increase in the amplitude of the H-reflex 2-4 hours after return to a 1-G environment. These alterations have been attributed to the adaptation of the human neurosensory system to gravity. The Hoffman reflex (H-reflex) is an acknowledged method to determine the integrity of the monosynaptic reflex arc. However deep tendon reflexes (DTR's or T-reflexes), elicited by striking the tendon also utilize the entire reflex arc. The objective of this study was to compare the variability in latency and amplitude of the two reflexes in healthy subjects. Methods: Nine healthy male subjects, 27-43 years in age, 161-175 cm in height plus 60-86 Kg in weight, underwent weekly testing for four weeks with a Dan-Tec EMG counterpoint EMG system. Subjects were studied prone and surface EMG electrodes were placed on the right and left soleus muscles. The H-reflex was obtained by stimulating the tibial nerve in the politeal fossa with a 0.2 msec square wave pulse delivered at 2 Hz until the maximum H-reflex was obtained. The T-reflex was invoked by tapping the achilles tendon with a self triggering reflex hammer connected to the EMG system. The latencies and amplitudes for the H- and T-reflexes were measured. Results: These data indicate that the amplitudes of these reflexes varied considerably. However, latencies to invoked responses were consistent. The latency of the T-reflex was approximately 3-5 msec longer than the H-reflex. Conclusion: The T-reflex is easily obtained, requires less time, and is more comfortable to perform. Qualitative data can be obtained by deploying self triggering, force plated reflex hammers both in the 1-G and Zero-G environment

    Mesoscopic Thermovoltage Measurement Design

    Full text link
    Quantitative thermoelectric measurements in the mesoscopic regime require accurate knowledge of temperature, thermovoltage, and device energy scales. We consider the effect of a finite load resistance on thermovoltage measurements of InAs/InP heterostructure nanowires. Load resistance and ac attenuation distort the measured thermovoltage therefore complicating the evaluation of device performance. Understanding these effects improves experimental design and data interpretation.Comment: 2 pages, 3 figure
    • …
    corecore