12 research outputs found

    Cerebral blood flow and glucose metabolism in healthy volunteers measured using a high-resolution PET scanner

    Get PDF
    BACKGROUND: Positron emission tomography (PET) allows for the measurement of cerebral blood flow (CBF; based on [(15)O]H(2)O) and cerebral metabolic rate of glucose utilization (CMR(glu); based on [(18) F]-2-fluoro-2-deoxy-d-glucose ([(18) F]FDG)). By using kinetic modeling, quantitative CBF and CMR(glu) values can be obtained. However, hardware limitations led to the development of semiquantitive calculation schemes which are still widely used. In this paper, the analysis of CMR(glu) and CBF scans, acquired on a current state-of-the-art PET brain scanner, is presented. In particular, the correspondence between nonlinear as well as linearized methods for the determination of CBF and CMR(glu) is investigated. As a further step towards widespread clinical applicability, the use of an image-derived input function (IDIF) is investigated. METHODS: Thirteen healthy male volunteers were included in this study. Each subject had one scanning session in the fasting state, consisting of a dynamic [(15)O]H(2)O scan and a dynamic [(18) F]FDG PET scan, acquired at a high-resolution research tomograph. Time-activity curves (TACs) were generated for automatically delineated and for manually drawn gray matter (GM) and white matter regions. Input functions were derived using on-line arterial blood sampling (blood sampler derived input function (BSIF)). Additionally, the possibility of using carotid artery IDIFs was investigated. Data were analyzed using nonlinear regression (NLR) of regional TACs and parametric methods. RESULTS: After quality control, 9 CMR(glu) and 11 CBF scans were available for analysis. Average GM CMR(glu) values were 0.33 ± 0.04 μmol/cm(3) per minute, and average CBF values were 0.43 ± 0.09 mL/cm(3) per minute. Good correlation between NLR and parametric CMR(glu) measurements was obtained as well as between NLR and parametric CBF values. For CMR(glu) Patlak linearization, BSIF and IDIF derived results were similar. The use of an IDIF, however, did not provide reliable CBF estimates. CONCLUSION: Nonlinear regression analysis, allowing for the derivation of regional CBF and CMR(glu) values, can be applied to data acquired with high-spatial resolution current state-of-the-art PET brain scanners. Linearized models, applied to the voxel level, resulted in comparable values. CMR(glu) measurements do not require invasive arterial sampling to define the input function. TRIAL REGISTRATION: ClinicalTrials.gov NCT0062608

    CBCT-based navigation system for open liver surgery: accurate guidance toward mobile and deformable targets with a semi-rigid organ approximation and electromagnetic tracking of the liver

    Get PDF
    Purpose The surgical navigation system that provides guidance throughout the surgery can facilitate safer and more radical liver resections, but such a system should also be able to handle organ motion. This work investigates the accuracy of intraoperative surgical guidance during open liver resection, with a semi-rigid organ approximation and electromagnetic tracking of the target area.Methods The suggested navigation technique incorporates a preoperative 3D liver model based on diagnostic 4D MRI scan, intraoperative contrast-enhanced CBCT imaging and electromagnetic (EM) tracking of the liver surface, as well as surgical instruments, by means of six degrees-of-freedom micro-EM sensors.Results The system was evaluated during surgeries with 35 patients and resulted in an accurate and intuitive real-time visualization of liver anatomy and tumor's location, confirmed by intraoperative checks on visible anatomical landmarks. Based on accuracy measurements verified by intraoperative CBCT, the system's average accuracy was 4.0 +/- 3.0 mm, while the total surgical delay due to navigation stayed below 20 min.Conclusions The electromagnetic navigation system for open liver surgery developed in this work allows for accurate localization of liver lesions and critical anatomical structures surrounding the resection area, even when the liver was manipulated. However, further clinically integrating the method requires shortening the guidance-related surgical delay, which can be achieved by shifting to faster intraoperative imaging like ultrasound. Our approach is adaptable to navigation on other mobile and deformable organs, and therefore may benefit various clinical applications.Radiolog

    CBCT‐based navigation system for open liver surgery: Accurate guidance toward mobile and deformable targets with a semi‐rigid organ approximation and electromagnetic tracking of the liver

    No full text
    Purpose The surgical navigation system that provides guidance throughout the surgery can facilitate safer and more radical liver resections, but such a system should also be able to handle organ motion. This work investigates the accuracy of intraoperative surgical guidance during open liver resection, with a semi-rigid organ approximation and electromagnetic tracking of the target area.Methods The suggested navigation technique incorporates a preoperative 3D liver model based on diagnostic 4D MRI scan, intraoperative contrast-enhanced CBCT imaging and electromagnetic (EM) tracking of the liver surface, as well as surgical instruments, by means of six degrees-of-freedom micro-EM sensors.Results The system was evaluated during surgeries with 35 patients and resulted in an accurate and intuitive real-time visualization of liver anatomy and tumor's location, confirmed by intraoperative checks on visible anatomical landmarks. Based on accuracy measurements verified by intraoperative CBCT, the system's average accuracy was 4.0 +/- 3.0 mm, while the total surgical delay due to navigation stayed below 20 min.Conclusions The electromagnetic navigation system for open liver surgery developed in this work allows for accurate localization of liver lesions and critical anatomical structures surrounding the resection area, even when the liver was manipulated. However, further clinically integrating the method requires shortening the guidance-related surgical delay, which can be achieved by shifting to faster intraoperative imaging like ultrasound. Our approach is adaptable to navigation on other mobile and deformable organs, and therefore may benefit various clinical applications.Radiolog

    In vivo quantification of striatal dopamine D-2 receptor occupancy by JNJ-37822681 using [C-11]raclopride and positron emission tomography

    No full text
    JNJ-37822681 is a novel, fast-dissociating dopamine D(2) receptor antagonist, currently in development as an antipsychotic drug candidate. A previous first-in-human study demonstrated mild central nervous system effects of JNJ-37822681 in healthy male volunteers. Significant but transient serum prolactin elevations were demonstrated, whereas other neurophysiological effects were relatively small. To investigate striatal dopamine D(2) receptor occupancy by variable single doses of JNJ-37822681, an open-label [(11)C]raclopride positron emission tomography study was performed in 12 healthy male volunteers, using the simplified reference tissue model with cerebellum as reference tissue. Oral administration of JNJ-37822681 resulted in dose-dependent dopamine D(2) receptor occupancy. Receptor occupancy increased from 9-19% at 2 mg doses to 60-74% at 20 mg doses of JNJ-37822681. Therefore, single oral doses of JNJ-37822681 can produce occupancy levels that are generally associated with clinical efficacy for registered antipsychotic drugs.Stress-related psychiatric disorders across the life spa
    corecore