48 research outputs found

    Self-field measurements of an HTS twisted stacked-tape cable conductor

    Get PDF
    For a twisted stacked-tape cable (TSTC) conductor composed of REBCO tapes, self-field measurements were conducted with Hall sensors. In the measurements, a 650 mm diameter single turn coil wound with the TSTC conductor, which was made with 48 REBCO tapes whose width was 6 mm, was utilized as a test sample. Based on the measurement results, the current distribution of the TSTC conductor was investigated with analytical models. The analytical results indicate the current distribution of the TSTC is uniform under the condition that the operating current is 10 kA and the sample temperature is approximately 30 K. On the other hand, the current distribution is not uniform at the excitation and the degauss of the TSTC conductor with the ramp rate of 50 A/s

    Effect of Direction of External Magnetic Field on Minimum Propagation Current of a Composite Conductor for LHD Helical Coils

    Get PDF
    The conductor for helical coils of the Large Helical Device consists of a Rutherford-type NbTi/Cu cable, a pure aluminum stabilizer, and a copper sheath. The dimensions of the conductor and the stabilizer cross-sections are 18.0 mm × 12.5 mm and 12.4 mm × 5.2 mm, respectively. The measured cold-end recovery current in the magnetic field parallel to the shorter side (B//12.5) is clearly lower than that in the field parallel to the longer side (B//18.0) because of the difference in magnetoresistance by Hall currents. Since the minimum propagation current Imp is important to determine the upper limit of operation current, Imp has been measured for two types of one-turn coil samples, which were bent flatwise (B//18.0) and edgewise (B//12.5) with the inner radius of 0.14 m to extend the length in the uniform background field of the test facility. The measured Imp at B//12.5 is almost the same as that at B//18.0 in spite of the large difference in the steady-state resistance. Imp is considered to be determined by the heat balance before the current diffuses deeply into the stabilizer

    Measurement of Decay Time Constant of Shielding Current in ITER-TF Joint Samples

    Get PDF
    Joint sample tests have been carried out as a qualification test for ITER Toroidal Field (TF) coils. The joint sample comprises two short TF conductors that have "twin-box" joint terminals at both ends. The lower joint is a testing part that is a full size joint of the TF coils. Hall probes are attached on the lower joint box at around the center of the external field coil of the test facility. The magnetic field induced by shielding currents in the joint can be estimated from the difference between the measured magnetic field strength and the magnetic field generated by the external field coil. The magnetic field by the shielding currents during shut-off of the external field coil from -1.0 T is evaluated for six samples. The decay time constants of the shielding currents are gradually elongated with decrease of the shielding currents in all the samples. In comparison with simulation results, it is considered that the main shielding current flows in superconducting cables in the two conductors with crossing the jointed plane and that the joint resistance is decreased at low total current

    Test of ITER-TF Joint Samples With NIFS Test Facilities

    Get PDF
    Qualification tests of the ITER toroidal field (TF) conductor joints have been carried out by testing joint samples with test facilities in the National Institute for Fusion Science, NINS, Toki, Japan. The joint sample consists of two short TF conductors with the length of 1535 mm, which is restricted by the test facility with 9-T split coils and 100-kA current leads. The sample current is supplied from a dc 75-kA power supply. Each conductor has two joint boxes at both terminals. The lower joint is a testing part that is a full-size joint of the TF coil. The joint resistance of the lower joint is estimated from the increase of the average voltage drop among the six taps on the conductor against the currents. Five joint samples were tested until 2016, and all the samples satisfied the requirement of the joint resistance at less than 3 nΩ. The method of the measurement and the results are summarized, and the voltage distribution among the voltage taps is discussed

    Results of All ITER TF Full-Size Joint Sample Tests in Japan

    Get PDF
    Nine toroidal field (TF) coils have been developed in Japan for the international thermonuclear experimental reactor (ITER). The joint resistance of TF coil should satisfy the requirement of smaller than 3 nano-ohm at 2 T of external magnetic field and 68 kA of transport current. Full-size joint sample (FSJS) tests were performed for joint development and for TF coil manufacture, as part of the process control. 11 FSJS tests are conducted in total. FSJS tests were conducted with assistance from a test faculty in the National Institute for Fusion Science as reported in a previous paper. All FSJS tests successfully satisfied the requirement of resistance less than 3 nΩ at 2 T. Additionally, the TF coil joints are subjected to cyclic electromagnetic force and warm-up/cool-down during the ITER operation. The authors investigated the joint performance for the abovementioned influence. The results showed no degradation in the joint resistance. Thus, the TF joint developed in Japan was qualified successfully

    Conductor and joint test results of JT-60SA CS and EF coils using the NIFS test facility

    Get PDF
    In 2007, JAEA and NIFS launched the test project to evaluate the performance of cable-in-conduit (CIC) conductors and conductor joints for the JT-60SA CS and EF coils. In this project, conductor tests for four types of coil conductor and joint tests for seven types of conductor joint have been conducted for the past eight years using the NIFS test facility. As a result, the test project indicated that the CIC conductors and conductor joints fulfill the design requirement for the CS and EF coils. In addition, the NIFS test facility is expected to be utilized as the test facility for the development of a conductor and conductor joint for the purpose of the DEMO nuclear fusion power plant, provided that the required magnetic field strength is within 9 T

    Study on Configuration of Conductor Samples for 13 T - 700 mm Test Facility

    Get PDF
    A 13 T test facility with a 700 mm cold bore has been utilized for the research of high-field and high-current superconductors for magnets of fusion reactors. Studies on configuration of a conductor sample have been carried out for simplification of the conductor sample and its supporting structure. Since sideways force and rotational moment are induced by an asymmetric current component of the sample, the route of feeders and the configuration of terminals of the sample must be optimized. The sample is set at the coaxial position in the center plane of the external field coil because a vertical or radial shift of the sample induces vertical or radial force. According to the structural analysis of the sample chamber, the allowable sideways force of the sample is estimated at 44 kN. Considering the electromagnetic force and the magnetic field at the terminals, representative configurations of one-turn samples are proposed. Concerning the number of turns of the conductor sample, a one-turn or rewound coil is preferred for a fast ramp rate of the sample current