118 research outputs found

    Optimization by Smoothed Bandpass Calibration in Radio Spectroscopy

    Full text link
    We have developed the Smoothed Bandpass Calibration (SBC) method and the best suitable scan pattern to optimize radio spectroscopic observations. Adequate spectral smoothing is applied to the spectrum toward OFF-source blank sky adjacent to a target source direction for the purpose of bandpass correction. Because the smoothing process reduces noise, the integration time for OFF-source scans can be reduced keeping the signal-to-noise ratio. Since the smoothing is not applied to ON-source scans, the spectral resolution for line features is kept. An optimal smoothing window is determined by bandpass flatness evaluated by Spectral Allan Variance (SAV). An efficient scan pattern is designed to the OFF-source scans within the bandpass stability timescale estimated by Time-based Allan Variance (TAV). We have tested the SBC using the digital spectrometer, VESPA, on the VERA Iriki station. For the targeted noise level of 5e-4 as a ratio to the system noise, the optimal smoothing window was 32 - 60 ch in the whole bandwidth of 1024 ch, and the optimal scan pattern was designed as a sequence of 70-s ON + 10-s OFF scan pairs. The noise level with the SBC was reduced by a factor of 1.74 compared with the conventional method. The total telescope time to achieve the goal with the SBC was 400 s, which was 1/3 of 1200 s required by the conventional way. Improvement in telescope time efficiency with the SBC was calculated as 3x, 2x and 1.3x for single-beam, dual-beam, and on-the-fly (OTF) scans, respectively. The SBC works to optimize scan patterns for observations from now, and also works to improve signal-to-noise ratios of archival data if ON- and OFF-source spectra are individually recorded, though the efficiency depends on the spectral stability of the receiving system.Comment: 12 pages, 11 figures, to appear in the Publications of Astronomical Society of Japan, Vol.64, No.

    Characterization of the effect of ion irradiation on industrially produced GdBa₂Cu₃O₇−δ superconducting tapes using a slow positron beam

    Get PDF
    To investigate the effect of irradiation-induced defects on the superconducting characteristics of industrially produced superconductor—GdBa₂Cu₃O₇−δ (GdBCO)—coated conductors (CCs), we irradiated the GdBCO CCs with Au ions at 2 or 10 MeV and probed them using a slow positron beam. Vacancy clusters were detected in both unirradiated and irradiated GdBCO CCs. However, the effect of ion irradiation on the GdBCO CCs was characterized as a slight reduction in the positron annihilation rate with low-momentum electrons. We also found a correlation between the annihilation rate of low-momentum electrons and the superconducting transition temperature

    High-Resolution Imaging of Patients with Bietti Crystalline Dystrophy with CYP4V2

    Get PDF
    The purpose of this study was to determine the retinal morphology of eyes with Bietti crystalline dystrophy (BCD) associated with a CYP4V2 mutation using high-resolution imaging techniques. Three subjects with BCD underwent detailed ophthalmic examinations. High-resolution fundus images were obtained with an adaptive optics (AO) fundus camera. A common homozygous mutation was detected in the three patients. Funduscopic examination of the three patients revealed the presence of crystalline deposits in the retina, and all of the crystalline deposits were also detected in the infrared (IR) images. The crystals observed in the IR images were seen as bright reflective plaques located on the RPE layer in the SD-OCT images. The clusters of hyperreflective signals in the AO images corresponded to the crystals in the IR images. High-magnification AO images revealed that the clusters of hyperreflective signals consisted of circular spots that are similar to the signals of cone photoreceptors. Most of these circular spots were detected in healthy areas in the FAF images. There is a possibility that circular spots observed by AO are residual cone photoreceptors located over the crystals

    Effects of pleasant sound on overnight sleep condition : A crossover randomized study

    Get PDF
    It is desirable to improve sleep quality since poor sleep results in decreases in work productivity and increases in risks of lifestyle-related diseases. Sleep spindles in sleep EEG are waveforms that characterize non-REM sleep Stage 2 (Stage N2). Music therapy has been adopted as a non-pharmacological therapy for sleep quality improvement; however, few studies mention the relationship between music during sleep and spindles. We conducted a crossover randomized study to investigate music\u27s effects on spindles and sleep parameters. Polysomnography (PSG) was performed on 12 adult males with sleep difficulties over three nights, during which they were exposed to three different acoustic environments–silent, white noise, and pleasant sounds–throughout the night, in a crossover randomized setting. Half of the participants with large WASO were defined as the sleep maintenance difficulty group. We investigated whether pleasant sounds shortened sleep onset latency (SOL) and increased the number of spindles (SN) and spindle density (SD) compared to white noise, using silent as the reference. The spindles were detected using the previously reported automatic spindle detection algorithm. After one patient was excluded due to data corruption, a total of 11 participants, including the sleep maintenance difficulty group (n = 5), were analyzed. For all participants, SOL was not significantly shorter with pleasant sound than with white noise (p = 0.683); for the sleep maintenance difficulty group, SOL tended to be shorter with pleasant sound than with white noise (p = 0.060). Compared to white noise, the SN increased in pleasant sound for 7 of 11 (4 of 5 in the sleep maintenance difficulty group), and SD increased for 5 of 11 (3 of 5 in the sleep maintenance difficulty group). The results suggest that all-night background sound exposure may affect SN and SD. Future research should investigate whether background sound exposure reduces sleep-related distress, achieves sound sleep, or improves daytime psychomotor function

    Different prognostic outcomes in two cases of FDG-PET/CT-Positive and -negative cardiac angiosarcoma

    Get PDF
    Cardiac angiosarcoma is a rare malignant tumor with a poor prognosis, characterized by the high uptake of 18F-fluorodeoxyglucose (FDG). This case report presents two cases of cardiac angiosarcoma with a marked difference in FDG uptake and prognosis.Case Summary:Case 1: A 40-year-old male presented with syncope. Ultrasound echocardiography demonstrated a cardiac tumor with a high uptake of 18F-FDG (maximum standardized uptake value=9.2). The patient underwent heart catheterization and tumor biopsy. The pathological result was high-grade angiosarcoma, and the MIB-1(Ki-67) proliferation index was approximately 20%. Systemic chemotherapy was administered; however, the patient died 2 years and 5 months after disease onset.Case 2: A 65-year-old female had a right atrial tumor incidentally diagnosed during routine ultrasound echocardiography. The tumor exhibited a low uptake of 18F-FDG (maximum standardized uptake value=1.8). Open heart surgery was performed, and the tumor was completely resected. Histological analysis revealed low-grade angiosarcoma, and the MIB-1(Ki-67) proliferation index was less than 5%. The patient was followed-up and had not relapsed 2 years after surgery.Conclusion: 18F-FDG uptake may reflect pathological tumor grade and prognosis in cardiac angiosarcoma
    corecore