14 research outputs found
Potential value of saline-induced Pd/Pa ratio in patients with coronary artery stenosis
BackgroundFractional flow reserve (FFR) is the current gold standard for identifying myocardial ischemia in individuals with coronary artery stenosis. However, FFR is not penetrated as much worldwide due to time consumption, costs associated with adenosine, FFR-related discomfort, and complications. Resting physiological indexes may be widely accepted alternatives to FFR, while the discrepancies with FFR were found in up to 20% of lesions. The saline-induced Pd/Pa ratio (SPR) is a new simplified option for evaluating coronary stenosis. However, the clinical implication of SPR remains unclear.ObjectivesIn the present study, we aimed to compare the accuracies of SPR and resting full-cycle ratio (RFR) and to investigate the incremental value of SPR in clinical practice.MethodsIn this multicenter prospective study, 112 coronary lesions (105 patients) were evaluated by SPR, RFR, and FFR.ResultsThe overall median age was 71 years, and 84.8% were men. SPR was correlated more strongly with FFR than with RFR (r = 0.874 vs. 0.713, respectively; p < 0.001). Using FFR < 0.80 as the reference standard variable, the area under the receiver-operating characteristic (ROC) curve for SPR was superior to that of RFR (0.932 vs. 0.840, respectively; p = 0.009).ConclusionSaline-induced Pd/Pa ratio predicted FFR more accurately than RFR. SPR could be an alternative method for evaluating coronary artery stenosis and further investigation including elucidation of the mechanism of SPR is needed (225 words)
Axillofemoral Bypass Markedly Improved Acute Decompensated Heart Failure and Kidney Injury in a Patient with Severely Calcified Stenosis of Thoracoabdominal Aorta (Atypical Aortic Coarctation)
Pulmonary Hypertension Caused by Persistent Anomalous Vertical Vein Bridging the Left Subclavian Vein and Left Atrium With Hypertrophic Cardiomyopathy
Development and Implementation of an Advanced Coronary Angiography and Intervention Database System
Development of Compton X-Ray Spectrometer for Fast Ignition Experiment
In the context of Fast Ignition, the fast electron temperature is a key parameter to determine the laser-to-fast electron energy conversion efficiency. Bremsstrahlung X-ray (γ-ray) emission represents an attractive alternative to measure this fundamental parameter. In this study, a single-shot high-energy γ-ray spectrometer with sensitivity ranging from 0.5 MeV to 7 MeV was developed, allowing to estimate the γ-ray spectrum in the fast ignition