193 research outputs found

    A summary of existing and planned experiment hardware for low-gravity fluids research

    Get PDF
    An overview is presented of (1) existing ground-based, low gravity research facilities, with examples of hardware capabilities, and (2) existing and planned space-based research facilities, with examples of current and past flight hardware. Low-gravity, ground-based facilities, such as drop towers and aircraft, provide the experimenter with quick turnaround time, easy access to equipment, gravity levels ranging from 10(exp -2) to 10(exp -6) G, and low-gravity durations ranging from 2 to 30 sec. Currently, the only operational space-based facility is the Space Shuttle. The Shuttle's payload bay and middeck facilities are described. Existing and planned low-gravity fluids research facilities are also described with examples of experiments and hardware capabilities

    Milestones Achieved for the Fluids and Combustion Facility

    Get PDF
    In 2004, President Bush outlined a new space exploration vision for NASA. The exploration programs will seek profound answers to questions of our origins, whether life exists beyond Earth, and how we could live in other worlds. In response, research projects from NASA s Fluid Physics Research Program were moved into the Exploration Systems Mission Directorate and realigned to support the major milestones of this directorate. A new goal of this research is to obtain an understanding of the physical phenomena that are important in the design of the many space-based and ground-based fluids systems that utilize multiphase flow, such as life support, propulsion, and power systems

    THE FLUIDS AND COMBUSTION FACILITY: ENABLING THE EXPLORATION OF SPACE

    Get PDF
    The Fluids and Combustion Facility (FCF) is an International Space Station facility designed to support physical and biological research as well as technology experiments in space. The FCF consists of two racks called the Combustion Integrated Rack (CIR) and the Fluids Integrated Rack (FIR). The capabilities of the CIR and the FIR and plans for their utilization will support the President s vision for space exploration. The CIR will accommodate physical research and technology experiments that address needs in the areas of spacecraft fire prevention, detection and suppression, incineration of solid wastes, and power generation. Initial experiments will provide data to support design decisions for exploration spacecraft. The CIR provides a large sealed chamber in a near-weightless environment. The chamber supports many simulated atmospheres including lunar or Martian environments. The FIR will accommodate experiments that address needs for advanced life support, power, propulsion, and spacecraft thermal control systems. The FIR can also serve as a platform for experiments that address human health and performance, medical technologies, and biological sciences. The FIR provides a large volume for payload hardware, reconfigurable diagnostics, customizable software, active rack-level vibration isolation, and data acquisition and management in a nearly uniform temperature environment

    Use of ChAd3-EBO-Z Ebola virus vaccine in Malian and US adults, and boosting of Malian adults with MVA-BN-Filo: a phase 1, single-blind, randomised trial, a phase 1b, open-label and double-blind, dose-escalation trial, and a nested, randomised, double-blind, placebo-controlled trial

    Get PDF
    SummaryBackgroundThe 2014 west African Zaire Ebola virus epidemic prompted worldwide partners to accelerate clinical development of replication-defective chimpanzee adenovirus 3 vector vaccine expressing Zaire Ebola virus glycoprotein (ChAd3-EBO-Z). We aimed to investigate the safety, tolerability, and immunogenicity of ChAd3-EBO-Z in Malian and US adults, and assess the effect of boosting of Malians with modified vaccinia Ankara expressing Zaire Ebola virus glycoprotein and other filovirus antigens (MVA-BN-Filo).MethodsIn the phase 1, single-blind, randomised trial of ChAd3-EBO-Z in the USA, we recruited adults aged 18–65 years from the University of Maryland medical community and the Baltimore community. In the phase 1b, open-label and double-blind, dose-escalation trial of ChAd3-EBO-Z in Mali, we recruited adults 18–50 years of age from six hospitals and health centres in Bamako (Mali), some of whom were also eligible for a nested, randomised, double-blind, placebo-controlled trial of MVA-BN-Filo. For randomised segments of the Malian trial and for the US trial, we randomly allocated participants (1:1; block size of six [Malian] or four [US]; ARB produced computer-generated randomisation lists; clinical staff did randomisation) to different single doses of intramuscular immunisation with ChAd3-EBO-Z: Malians received 1 × 1010 viral particle units (pu), 2·5 × 1010 pu, 5 × 1010 pu, or 1 × 1011 pu; US participants received 1 × 1010 pu or 1 × 1011 pu. We randomly allocated Malians in the nested trial (1:1) to receive a single dose of 2 × 108 plaque-forming units of MVA-BN-Filo or saline placebo. In the double-blind segments of the Malian trial, investigators, clinical staff, participants, and immunology laboratory staff were masked, but the study pharmacist (MK), vaccine administrator, and study statistician (ARB) were unmasked. In the US trial, investigators were not masked, but participants were. Analyses were per protocol. The primary outcome was safety, measured with occurrence of adverse events for 7 days after vaccination. Both trials are registered with ClinicalTrials.gov, numbers NCT02231866 (US) and NCT02267109 (Malian).FindingsBetween Oct 8, 2014, and Feb 16, 2015, we randomly allocated 91 participants in Mali (ten [11%] to 1 × 1010 pu, 35 [38%] to 2·5 × 1010 pu, 35 [38%] to 5 × 1010 pu, and 11 [12%] to 1 × 1011 pu) and 20 in the USA (ten [50%] to 1 × 1010 pu and ten [50%] to 1 × 1011 pu), and boosted 52 Malians with MVA-BN-Filo (27 [52%]) or saline (25 [48%]). We identified no safety concerns with either vaccine: seven (8%) of 91 participants in Mali (five [5%] received 5 × 1010 and two [2%] received 1 × 1011 pu) and four (20%) of 20 in the USA (all received 1 × 1011 pu) given ChAd3-EBO-Z had fever lasting for less than 24 h, and 15 (56%) of 27 Malians boosted with MVA-BN-Filo had injection-site pain or tenderness.Interpretation1 × 1011 pu single-dose ChAd3-EBO-Z could suffice for phase 3 efficacy trials of ring-vaccination containment needing short-term, high-level protection to interrupt transmission. MVA-BN-Filo boosting, although a complex regimen, could confer long-lived protection if needed (eg, for health-care workers).FundingWellcome Trust, Medical Research Council UK, Department for International Development UK, National Cancer Institute, Frederick National Laboratory for Cancer Research, Federal Funds from National Institute of Allergy and Infectious Diseases

    Ultra-Fast and Sensitive Detection of Non-Typhoidal Salmonella Using Microwave-Accelerated Metal-Enhanced Fluorescence (“MAMEF”)

    Get PDF
    Certain serovars of Salmonella enterica subsp. enterica cause invasive disease (e.g., enteric fever, bacteremia, septicemia, meningitis, etc.) in humans and constitute a global public health problem. A rapid, sensitive diagnostic test is needed to allow prompt initiation of therapy in individual patients and for measuring disease burden at the population level. An innovative and promising new rapid diagnostic technique is microwave-accelerated metal-enhanced fluorescence (MAMEF). We have adapted this assay platform to detect the chromosomal oriC locus common to all Salmonella enterica subsp. enterica serovars. We have shown efficient lysis of biologically relevant concentrations of Salmonella spp. suspended in bacteriological media using microwave-induced lysis. Following lysis and DNA release, as little as 1 CFU of Salmonella in 1 ml of medium can be detected in <30 seconds. Furthermore the assay is sensitive and specific: it can detect oriC from Salmonella serovars Typhi, Paratyphi A, Paratyphi B, Paratyphi C, Typhimurium, Enteritidis and Choleraesuis but does not detect Escherichia coli, Pseudomonas aeruginosa, Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae or Acinetobacter baumanii. We have also performed preliminary experiments using a synthetic Salmonella oriC oligonucleotide suspended in whole human blood and observed rapid detection when the sample was diluted 1∶1 with PBS. These pre-clinical data encourage progress to the next step to detect Salmonella in blood (and other ordinarily sterile, clinically relevant body fluids)

    A precautionary public health protection strategy for the possible risk of childhood leukaemia from exposure to power frequency magnetic fields

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Epidemiological evidence showing a consistent association between the risk of childhood leukaemia and exposure to power frequency magnetic fields has been accumulating. This debate considers the additional precautionary intervention needed to manage this risk, when it exceeds the protection afforded by the exposure guidelines as recommended by the International Commission on Non-Ionizing Radiation Protection.</p> <p>Methods</p> <p>The Bradford-Hill Criteria are guidelines for evaluating the scientific evidence that low frequency magnetic fields cause childhood leukaemia. The criteria are used for assessing the strength of scientific evidence and here have been applied to considering the strength of evidence that exposures to extremely low frequency magnetic fields may increase the risk of childhood leukaemia. The applicability of precaution is considered using the risk management framework outlined in a European Commission (EC) communication on the Precautionary Principle. That communication advises that measures should be proportionate, non-discriminatory, consistent with similar measures already taken, based on an examination of the benefits and costs of action and inaction, and subject to review in the light of new scientific findings.</p> <p>Results</p> <p>The main evidence for a risk is an epidemiological association observed in several studies and meta-analyses; however, the number of highly exposed children is small and the association could be due to a combination of selection bias, confounding and chance. Corroborating experimental evidence is limited insofar as there is no clear indication of harm at the field levels implicated; however, the aetiology of childhood leukaemia is poorly understood. Taking a precautionary approach suggests that low-cost intervention to reduce exposure is appropriate. This assumes that if the risk is real, its impact is likely to be small. It also recognises the consequential cost of any major intervention. The recommendation is controversial in that other interpretations of the data are possible, and low-cost intervention may not fully alleviate the risk.</p> <p>Conclusions</p> <p>The debate shows how the EC risk management framework can be used to apply the Precautionary Principle to small and uncertain public health risks. However, despite the need for evidence-based policy making, many of the decisions remain value driven and therefore subjective.</p

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    The FCF Fluids Integrated Rack: Microgravity Fluid Physics Experimentation on Board the ISS

    No full text
    The Fluids Integrated Rack (FIR) is a modular, multi-user scientific research facility that will fly in the U.S. laboratory module, Destiny, of the International Space Station (ISS). The FIR will be one of the racks that will constitute the Fluids and Combustion Facility (FCF). The ISS will provide the FCF and therefore the FIR with the necessary resources, such as power and cooling, so that the FIR can carry out its primary mission of accommodating fluid physics science experiments. This paper discusses the mission, design, and the capabilities of the FIR in carrying out research on the ISS
    corecore