117 research outputs found

    Relativistic mean field description for the shears band mechanism in 84^{84}Rb

    Get PDF
    For the first time, the Relativistic Mean Field (RMF) model is applied to the shears band recently observed in 3784_{37}^{84}Rb. Signals of the appearance of the shears mechanism, such as smooth decreases of the shears angle and of the BB(M1)/BB(E2) ratio with keeping the nearly constant tilt angle, are well reproduced. Thus it is shown that the microscopic RMF model can nicely describe the shears band in this nucleus.Comment: 5 pages, 6 eps figures included, uses REVTeX and epsf.sty, to appear in Phys. Rev.

    The Effect of Touching a Dolphin on the EEG Slow Waves hi Children

    Get PDF
    Among animal-facilitated therapies, dolphin-facilitated therapy has been shown to beneficially affect human behavior, emotion and speech ability. We recently showed that touching a dolphin reduced the respiratory rate and state anxiety in healthy children. In this study, we collected electroencephalographic data (EEG), widely used for examining various brain functions, before and after touching dolphins. We examined the relationship between EEG power spectra and individual trait anxiety scores. The results showed that the appearance of slow waves in the frontal area increased significantly after touching a dolphin. Furthermore, the difference in slow wave activity was negatively, but significantly, correlated with trait anxiety in the frontal area. This negative correlation showed that slow wave power was greater in subjects with lower trait anxiety, indicating that touching a dolphin may be more effective for subjects with low trait anxiety than those with high trait anxiety. However, even though the increase in slow wave power was lower in subjects with high trait anxiety, touching a dolphin appeared to affect brain rhythms by increasing slow waves

    Evaluation of Setup Errors at the Skin Surface Position for Whole Breast Radiotherapy of Breast Cancer Patients

    Get PDF
    We used image-processing software to analyze the setup errors at the skin surface position of breast cancer patients (n=66) who underwent post-operative whole breast irradiation at our hospital in 2014-2015. The sixty-six digital reconstructed radiographs (DRR) were created at the treatment planning for each patient. The lineacgraphies (n=377) were taken after the patients’ setup during radiotherapy. The lineacgraphies and DRR were superimposed at the skin surface position for each patient with the image-processing software. We measured the deviations of the isocenters for the nipple-lung (X) direction and craniocaudal (Y) direction and the deviation of the rotation angle of the XY axes between the lineacgraphy and DRR on the superimposed images. The systematic error (μ, Σ) and random error (σ) were calculated from the X and Y deviations and rotation angle deviation. The μ of X, Y, and rotation angle were 0.01 mm, −1.2 mm, and 0.05°, respectively. The Σ of X, Y, and rotation angle were 1.8 mm, 1.5 mm, and 0.9°, respectively. The σ of X, Y, and rotation angle were 2.0 mm, 1.5 mm, and 1.0°, respectively. Our analyses thus revealed that evaluations using image-processing software at the skin surface position in routine breast radiotherapy result in sufficiently small setup errors

    Carnitine for Body Composition in Hemodialysis Patients

    Get PDF
    Background: Authors and colleagues have continued clinical research for hemodialysis patients. Currently, a pilot study presents intervention of carnitine for changes of the body composition. Subjects and Methods: Subjects were six patients on hemodialysis with intervention of carnitine (group 1). Average data were 74.3 years, 65.4 kg, 22.6 in BMI. As levocarnitine, L-Cartin FF injection 1000 mg was administered three times a week for six months. Group 2 has six control patients for age-, sex-, body weight, BMI-matched (group 2). Body composition of muscle and fat tissues were measured by InBody 770 on 0 and 6 months. Results: In group 1, muscle volume and skeletal muscle showed increasing tendency without statistical significance. In contrast, there were significant decreases of body fat volume (22.3 kg vs 20.5 kg, 39.0% vs 35.8%) (p<0.05). No significant differences were found in hemoglobin, total protein, albumin and Cardio-Thoracic Ratio (CTR) of chest X-ray. Group 2 showed no significant changes. Discussion and Conclusion: Hemodialysis patients often have muscular reduction. Previous reports showed improved lean body mass by carnitine administration, which may support our result. These results from current pilot study would be expected to become useful reference data in the pathophysiological investigation in patients on hemodialysis

    General Relativistic Mean Field Theory for Rotating Nuclei

    Full text link
    We formulate a general relativistic mean field theory for rotating nuclei starting from the special relativistic σω\sigma - \omega model Lagrangian. The tetrad formalism is adopted to generalize the model to the accelerated frame.Comment: 13 pages, REVTeX, no figures, submitted to Phys. Rev. Lett., the word `curved' is replaced by `non-inertial' or `accelerated' in several places to clarify the physical situation interested, some references are added, more detail discussions are given with omitting some redundant sentence

    FDG-PET/CTでの浸潤性膵管癌以外の膵腫瘍の悪性病変の検出能における視覚評価と標準摂取率での評価の比較検討

    Get PDF
    Introduction The utility of FDG PET/CT for the detection and evaluation of invasive ductal carcinoma has been widely reported, but a few studies have assessed the utility of FDG PET/CT to detect malignancy in a variety of pancreatic lesions other than invasive ductal carcinoma. Purpose To compare the diagnostic performance of visual estimation with the semi-quantitative scores of FDG PET/CT for detecting malignancy in a variety of pancreatic lesions other than invasive ductal carcinoma. Material and Methods Images of pathologically proven pancreatic lesions from 32 patients were retrospectively evaluated : 14 benign lesions, 7 borderline (low malignant) lesions, and 11 malignant lesions. The average scores from visual estimation by the two observers were compared to two semi-quantiative analyses of FDG uptake in the lesions, namely the maximum standardized uptake value (SUVmax) and mean standardized uptake value (SUVmean). Results Visual analysis value, SUVmax and SUVmean were 0.33±0.21, 1.8±0.7 and 1.5±0.7 for the benign lesions, 0.70±0.28, 5.0±2.6 and 3.1±1.7 for the borderline lesions, and 0.73±0.18, 4.7±2.5 and 3.2±1.6 for the malignant lesions, respectively. Receiver operating characteristic analysis revealed the areas under the curves for detecting non-benign (malignant or borderline) lesions through visual analysis, SUVmax, and SUVmean were 0.914, 0.954, and 0.875, respectively. Conclusion For a variety of pancreatic lesions other than invasive ductal carcinoma, visual analysis and semi-quantitative analyses all showed strong diagnostic performance. However, semi-quantitative analysis with SUVmax proved to be the most effective method for detecting non-benign pancreatic lesions
    corecore