10 research outputs found

    Determining kinetic constants and transport efficiencies at membrane interfaces to optimize the removal/recovery of Cu(II) through lulk liquid membranes containing benzoylacetone as carrier

    Get PDF
    The removal, separation, and enrichment of heavy metals in aqueous solutions has become a prime concern over the last few decades because of both their adverse effects on the ecosystem and living organisms and their valuable resource character. This paper describes a study to optimize the simultaneous removal/ recovery of Cu(II) from aqueous solutions by bulk liquid membranes, through a facilitated countertransport mechanism using benzoylacetone as a mobile carrier and hydrochloric acid as a stripping agent (protons as counter ions), by analyzing the effect of different operational variables (carrier concentration in membrane phase, stripping agent concentration in product phase, stirring rate, and membrane phase volume) on the removal/recovery kinetics constants and on the transport efficiencies through the feed/membrane and membrane/product interfaces.We would like to thank Mr. A. Guzmán and Mr. J.A. López for manufacturing the experimental cell

    Estudi comparatiu d’eliminació de compostos fenòlics utilitzant la membrana NF-99 de poliamida

    Get PDF
    [SPA] Actualmente los procesos físicos basados en la tecnología de membranas se han aplicado satisfactoriamente para el tratamiento de aguas residuales, siendo la nanofiltración y la ósmosis inversa los métodos más adecuados para la eliminación de microcontaminantes orgánicos como los compuestos fenólicos. En este trabajo se ha realizado un estudio comparativo sobre el comportamiento de la membrana NF-99 en el proceso de eliminación de fenol, 4-clorofenol y 4-cloro-2-metilfenol. Además, la membrana NF-99 se ha caracterizado con una disolución de cloruro de magnesio, estudiando la influencia de la presión de operación sobre los parámetros característicos del sistema, flujo de permeado y coeficiente de rechazo, antes de realizar la experimentación y tras la realización de los ensayos. De la caracterización de la membrana se obtuvo unos valores en los flujos de permeado y en los coeficientes de rechazo prácticamente constantes, tanto en los ensayos realizados en las condiciones iniciales como en las condiciones finales. El compuesto 4-cloro-2-metilfenol obtuvo los mayores coeficientes de rechazo en todas las condiciones de presión, concentración de alimentación y pH ensayados.[ENG] Nowadays the physical processes based on membrane technology have been successfully applied for the treatment of wastewater being nanofiltration and reverse osmosis the best methods for removing organic micropollutants such as phenolic compounds. In this work a comparative study on the behaviour of the NF-99 membrane in the process of elimination of phenol, 4-chlorophenol and 4-chloro-2-methylphenol has been carried out. In addition, the NF-99 membrane has been characterized by a solution of magnesium chloride, studying the influence of the operating pressure on the characteristic parameters of the system, the permeate flux and rejection coefficient, before and after the experimental series. From the membrane characterization, nearly constant values of the permeate flux and rejection coefficients were obtained for both the initial and the final conditions. The compound 4-chloro-2-methylphenol obtained higher rejection coefficients in all conditions of pressure, feed concentration and pH tested.[CAT] Actualment els processos fisics basats en la tecnologia de membranes s’han aplicat satisfactoriament pel tractament d’aigues residuals, i la nanofiltracio i l’osmosi inversa son els metodes mes adequats per a l’eliminacio de microcontaminants organics com els compostos fenolics. En aquest treball s’ha realitzat un estudi comparatiu sobre el comportament de la membrana NF-99 en el proces d’eliminacio de fenol, 4-clorofenol i 4-cloro-2-metilfenol. A mes, la membrana NF-99 s’ha caracteritzat amb una dissolucio de clorur de magnesi, estudiant la influencia de la pressio d’operacio sobre els parametres caracteristics del sistema, flux de permeacio i coeficient de rebuig, abans de realitzar l’experimentacio i despres de la realitzacio dels assajos. De la caracteritzacio de la membrana es van obtenir uns valors en els fluxos de permeacio i en els coeficients de rebuig practicament constants, tant en els assajos realitzats en les condicions inicials com en les condicions finals. El compost 4-cloro-2-metilfenol va obtenir els majors coeficients de rebuig a totes les condicions de pressio, concentracio d’alimentacio i pH assajats.Este trabajo es resultado del proyecto de investigación 08683/PI/08, financiado por la Fundación Séneca, Agencia de Ciencia y Tecnología de la Región de Murcia (España). M.D. Murcia fue beneficiaria de la beca Juan de la Cierva de MICINN

    Separación enzimática de los isomeros de DL-Valina en reactores de lecho fijo y fluidizado / Asunción María Hidalgo Montesinos ; directoras Elisa Gómez Gómez, María Fuensanta Máximo Martín.

    No full text
    Tesis-Universidad de Murcia.Consulte la tesis en: BCA. GENERAL. ARCHIVO UNIVERSITARIO. T.M.-1432.CRAI CIENCIAS. DEPOSITO. T.D. 288

    Application of the Spiegler-Kedem-Kachalsky model to the removal of 4-chlorophenol by different nanofiltration membranes

    No full text
    © . This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Accepted Manuscript version of a Published Work that appeared in final form in [Desalination]. To access the final edited and published work see [https://www.sciencedirect.com/science/article/pii/S0011916412005656?via%3Dihub].”Chlorophenols, commonly found in the wastewaters of numerous industries, are widely considered as priority pollutants and their persistence may cause severe environmental problems. Among the methods described for their removal, pressure-driven membrane processes are considered as a reliable alternative. In this paper we study the influence of different operational variables (applied pressure, feed concentration and pH) on the removal of 4-chlorophenol from synthetic aqueous solutions by nanofiltration using three different polyamide membranes (NF-97, NF-99 and RO98pHt). The Spiegler-Kedem-Kachalsky model was applied to predict the nanofiltration removal process. Model constants for the three membranes were obtained and there was good agreement between the experimental and model rejection data

    Kinetic study of the enzymatic synthesis of 2-phenylethyl acetate in discontinuous tank reactor

    No full text
    This document is the Accepted Manuscript version of a Published Work that appeared in final form in [Kinetic study of the enzymatic synthesis of 2-Phenyl-ethyl acetate in discontinuous tank reactor], copyright © American Chemical Society, after peer review and technical editing by the publisher. To access the final edited and published work see [https://pubs.acs.org/doi/10.1021/acs.iecr.8b02058].There is increasing interest in new processes to produce aromatics labeled as “natural” and, as a consequence, enzymatic processes, in some organic solvent or in solvent-free medium, have been developed. This paper offers a kinetic study of lipase-catalyzed transesterification for synthesizing 2-phenyl-ethyl acetate in a batch reactor, using Novozym® 435 and hexane as solvent. Influence of five variables on the conversion is studied. A pseudo-first order kinetic model, derived as a simplification of a Bisubstrate Ping-Pong kinetics, is presented. The amount of catalyst was the variable most affecting kinetic and yield, while initial substrate concentration had little effect on the reaction kinetic. Yield increased gradually as the molar ratio increased, and was more pronounced with vinyl acetate than 2-phenethyl alcohol. Michaelis constants of both substrates and maximum reaction rate, for the range of assayed experimental conditions of temperature, stirring speed and enzyme concentration, were determined and compared with others in the literature. Finally, the proposed kinetic model was validated with high correlation coefficients

    Nanofiltration membranes to reduce phenol concentration in wastewater

    No full text
    ©. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Accepted Manuscript version of a Published Work that appeared in final form in [Desalination]. To access the final edited and published work see [https://www.sciencedirect.com/science/article/pii/S0011916409003889?via%3Dihub].Physical, chemical and biological methods have been described to remove phenolic compounds. None of them are the definitively solution of the environmental problem caused by the discharge of this pollutants. Hybrid processes that combine pressure driven membrane processes with adsorption processes have been developed. Our research group studied the removal of phenol with three reverse osmosis membranes, the rejection percentages obtained were very low (40%), besides this parameter increases when the operating pressure decreases. For this reason, in this paper, a study of phenol removal from aqueous solutions by nanofiltration using different experimental conditions (feed phenol concentration, pressure and pH) and different membranes (NF-97, NF-99 and DSS-HR98PP) is carried out. Water permeability coefficients were also obtained. The best results are obtained with DSS-HR98PP membrane increasing the rejection percentage up to 80%

    El uso de la energía en los museos de la Región de Murcia

    No full text
    El cambio climático exige una respuesta adaptativa por parte de todos los ámbitos de la sociedad. Los museos siempre se han caracterizado por considerarse a sí mismos referentes sociales, por lo que algunos de ellos ya se proponen como modelos para la implantación de medidas sostenibles[1]. El esfuerzo de los museos por mantener unas condiciones estables de temperatura y humedad genera el mayor consumo energético de estas instituciones, supone un gasto económico importante y a su vez tiene un impacto medioambiental que debe ser medido, analizado y reducido en la medida de lo posible [2][3]. El presente estudio analiza las mediciones y mejoras en materia de energía, mediante una encuesta realizada a treinta y un museos de la Región de Murcia. La muestra, seleccionada de la lista de la Oficina Regional de Turismo, y con especial interés en aquellos pertenecientes a la Red Regional de Museos, obtiene datos de los museos con instalaciones edilicias y salas de exposiciones con especial afluencia de visitantes o interés artístico, habiéndose excluido de este estudio los yacimientos arqueológicos, la mayoría de museos etnográficos y algunos museos cuya exposición no tiene necesidades especiales de conservación. Las encuestas se cumplimentaron de forma telefónica, al tiempo que las respuestas se incluían en la base de datos de Encuestas del portal de la Universidad de Murcia. Se preguntó a los equipos directivos de dichos museos si tenían conocimiento de haber realizado auditorías, alguna mejora energética en los últimos cinco años, así como la clasificación energética del edificio en que se ubica el museo. Las respuestas arrojaron unos resultados que llaman la atención por las pocas auditorías que se han realizado, o si se han realizado, los directivos no tienen conocimiento de ellas. Lo mismo ocurre con la eficiencia energética de los edificios: la mayoría de los encuestados respondieron no saber la letra correspondiente a la clasificación del edificio en que se encuentran ubicados. En materia de mejoras, la mayoría admitió haber realizado algunos cambios en materia energética, generalmente consistente en cambios en la iluminación, apostando por la iluminación LED, y en un par de casos se habían producido cambios en la maquinaria de la climatización, pero reconocieron no haber prestado especial atención a la eficiencia de dichos aparatos. De todos estos datos, se puede concluir que la eficiencia energética no forma parte de las preocupaciones del personal directivo de los museos, carecen de formación e información para abordar este tema. Para poder llevar a cabo un cambio significativo, y convertir los museos en centros medioambientalmente sostenibles, es necesario empezar por formar a los que trabajan en su gestión

    Application of reverse osmosis to remove aniline from wastewater

    No full text
    ©. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Accepted Manuscript version of a Published Work that appeared in final form in [Desalination]. To access the final edited and published work see [https://www.sciencedirect.com/science/article/pii/S0011916409003889?via%3Dihub].The presence of organic toxic solutes in industrial wastewater is a common environmental problem. Aniline is known to be a harmful and persistent pollutant and its presence in wastewater requires treatment before disposal. The performance of reverse osmosis to remove aniline from aqueous solutions is studied in this paper. The study has been carried out in a flat membrane test module using three thin layer composite membranes, two of polyamide, HR98PP and SEPA-MS05, and one of polyether sulphone, DESAL-3B. Recycling of both concentrate and permeate has been carried out in order to keep the feed concentration practically constant and so simulate a continuous process in a quasi-stationary state. The influence of different operational variables (pressure, feed volumetric flow rate, feed concentration and pH) on the performance of the aniline removal process is analyzed
    corecore