4 research outputs found

    Bed sensor technology for objective sleep monitoring within the clinical rehabilitation setting: Observational feasibility study

    Get PDF
    Contains fulltext : 232740.pdf (Publisher’s version ) (Open Access)BACKGROUND: Since adequate sleep is essential for optimal inpatient rehabilitation, there is an increased interest in sleep assessment. Unobtrusive, contactless, portable bed sensors show great potential for objective sleep analysis. OBJECTIVE: The aim of this study was to investigate the feasibility of a bed sensor for continuous sleep monitoring overnight in a clinical rehabilitation center. METHODS: Patients with incomplete spinal cord injury (iSCI) or stroke were monitored overnight for a 1-week period during their in-hospital rehabilitation using the Emfit QS bed sensor. Feasibility was examined based on missing measurement nights, coverage percentages, and missing periods of heart rate (HR) and respiratory rate (RR). Furthermore, descriptive data of sleep-related parameters (nocturnal HR, RR, movement activity, and bed exits) were reported. RESULTS: In total, 24 participants (12 iSCI, 12 stroke) were measured. Of the 132 nights, 5 (3.8%) missed sensor data due to Wi-Fi (2), slipping away (1), or unknown (2) errors. Coverage percentages of HR and RR were 97% and 93% for iSCI and 99% and 97% for stroke participants. Two-thirds of the missing HR and RR periods had a short duration of ≤120 seconds. Patients with an iSCI had an average nocturnal HR of 72 (SD 13) beats per minute (bpm), RR of 16 (SD 3) cycles per minute (cpm), and movement activity of 239 (SD 116) activity points, and had 86 reported and 84 recorded bed exits. Patients with a stroke had an average nocturnal HR of 61 (SD 8) bpm, RR of 15 (SD 1) cpm, and movement activity of 136 (SD 49) activity points, and 42 reported and 57 recorded bed exits. Patients with an iSCI had significantly higher nocturnal HR (t(18)=-2.1, P=.04) and movement activity (t(18)=-1.2, P=.02) compared to stroke patients. Furthermore, there was a difference between self-reported and recorded bed exits per night in 26% and 38% of the nights for iSCI and stroke patients, respectively. CONCLUSIONS: It is feasible to implement the bed sensor for continuous sleep monitoring in the clinical rehabilitation setting. This study provides a good foundation for further bed sensor development addressing sleep types and sleep disorders to optimize care for rehabilitants

    Using sensor technology to measure gait capacity and gait performance in rehabilitation inpatients with neurological disorders

    No full text
    The aim of this study was to objectively assess and compare gait capacity and gait performance in rehabilitation inpatients with stroke or incomplete spinal cord injury (iSCI) using inertial measurement units (IMUs). We investigated how gait capacity (what someone can do) is related to gait performance (what someone does). Twenty-two inpatients (11 strokes, 11 iSCI) wore ankle positioned IMUs during the daytime to assess gait. Participants completed two circuits to assess gait capacity. These were videotaped to certify the validity of the IMU algorithm. Regression analyses were used to investigate if gait capacity was associated with gait performance (i.e., walking activity and spontaneous gait characteristics beyond therapy time). The ankle positioned IMUs validly assessed the number of steps, walking time, gait speed, and stride length (r >= 0.81). The walking activity was strongly (r >= 0.76) related to capacity-based gait speed. Maximum spontaneous gait speed and stride length were similar to gait capacity. However, the average spontaneous gait speed was half the capacity-based gait speed. Gait capacity can validly be assessed using IMUs and is strongly related to gait performance in rehabilitation inpatients with neurological disorders. Measuring gait performance with IMUs provides valuable additional information about walking activity and spontaneous gait characteristics to inform about functional recovery
    corecore