3,791 research outputs found

    Helium 3/Helium 4 dilution cryocooler for space

    Get PDF
    Prototype dilution cryocoolers based on dilution refrigeration and adiabatic demagnetization refrigeration (ADR) cycles were designed, constructed, and tested. Although devices the devices did not operate as fully functional dilution cryocoolers, important information was gathered. The porous metal phase separator was demonstrated to operate in the -1-g configuration; this phase separation is the critical element in the He-3 circulation dilution cryocooler. Improvements in instrumentation needed for additional tests and development were identified

    Superconducting gyroscope research

    Get PDF
    Four basic areas of research and development of superconducting gyroscopes are studied. Chapter 1 studies the analysis of a SQUID readout for a superconducting gyroscope. Chapter 2 studies the dependence of spin-up torque on channel and gas properties. Chapter 3 studies the theory of super fluid plug operation. And chapter 4 studies the gyro rotor and housing manufacture

    Infrared telescope

    Get PDF
    The development of the Infrared Telescope for Spacelab 2 is discussed. The design, development, and testing required to interface a stationary superfluid helium dewar with a scanning cryostate capable of operating in the zero-g environment in the space shuttle bay is described

    Simulated breath waveform control

    Get PDF
    Subsystem was developed which provides twelve waveform controls to breath drive mechanism. Twelve position, magnetically actuated rotary switch is connected to one end of crankshaft drive, such that it makes one complete revolution for each simulated breath. Connections with common wired point are included in modifications made to standard motor speed controller

    GRADUATES’ PERSPECTIVES ON TRANSITION FROM COLLEGE GRADUATION TO THE WORKPLACE: A QUALITATIVE APPROACH

    Get PDF
    This article explored the experiences of college graduates in their program of study and during their transition from college graduation to the workplace. Factors focused on were perceptions of program and curriculum, employment preparation, connections to faculty and relationships with family members. Six individuals who graduated from the University of Kentucky Family Sciences (FAM) Department were interviewed. Participants openly shared positive and negative experiences. The study was examined through two theoretical lenses: Glen Elder’s life course perspective and Ludwig von Bertalanffy’s general systems theory. Participant interviews were transcribed verbatim and transcriptions were analyzed with inductive coding. Central themes that emerged included connections and networking, feelings in classes/curriculum/program, support and challenges within family relationships, transferring majors, ambiguity and lack of direction and graduate school. Findings from the study showed that graduates generally felt positively about their program of study and its translation to the workplace, though challenges were experienced in understanding what FAM was and what type of job it could lead to. Connections and networking within personal and professional relationships were found to be a crucial component of experiences

    Breathing-metabolic simulator

    Get PDF
    Breathing-metabolic simulator was developed to be used for evaluation of life support equipment. Apparatus simulates human breathing rate and controls temperature and humidity of exhaled air as well as its chemical composition. All functions are designed to correspond to various degrees of human response

    Measurements of bremsstrahlung produced by 0.75 and 1.25 mev electrons incident on typical apollo wall sections

    Get PDF
    Bremsstrahlung measurements on Apollo spacecraft wall sections irradiated with 0.75 and 1.25 MeV electrons from electron accelerato

    Drive mechanism for production of simulated human breath

    Get PDF
    Simulated breath drive mechanism was developed as subsystem to breathing metabolic simulator. Mechanism reproduces complete range of human breath rate, breath depth, and breath waveform, as well as independently controlled functional residual capacity. Mechanism was found capable of simulating various individual human breathing characteristics without any changes of parts

    A small, single stage orifice pulse tube cryocooler demonstration

    Get PDF
    This final report summarizes and presents the analytical and experimental progress in the present effort. The principal objective of this effort was the demonstration of a 0.25 Watt, 80 Kelvin orifice pulse tube refrigerator. The experimental apparatus is described. The design of a partially optimized pulse tube refrigerator is included. The refrigerator demonstrates an ultimate temperature of 77 K, has a projected cooling power of 0.18 Watts at 80 K, and has a measured cooling power of 1 Watt at 97 K, with an electrical efficiency of 250 Watts/Watt, much better than previous pulse tube refrigerators. A model of the pulse tube refrigerator that provides estimates of pressure ratio and mass flow within the pulse tube refrigerator, based on component physical characteristics is included. A model of a pulse tube operation based on generalized analysis which is adequate to support local optimization of existing designs is included. A model of regenerator performance based on an analogy to counterflow heat exchangers is included
    • …
    corecore