141 research outputs found

    Utilisation of cardiac pacemakers over a 20-year period: Results from a nationwide pacemaker registry

    Get PDF
    The implantation of cardiac pacemakers has become a well-established therapy for conduction disorders and sinus node dysfunction. In many countries pacemaker registries have been initiated in order to collect information on patient characteristics, trends in numbers and the types of pacemakers used, to identify problematic devices, and for safety monitoring. For this utilisation study the Central Pacemaker Patients Registration (CPPR) from the Netherlands Pacemaker Registry Foundation (CPPR-SPRN) containing data collected for more than 20 years was used. During this period nearly 97,000 first pacemakers were implanted. Analyses show an increase in the rate of implanted devices. The change in pacemaker type from VVI to DDD, followed by biventricular stimulation, is reflected by the number of simultaneously implanted leads, which is partly a consequence of cardiac resynchronisation therapy. Our data demonstrate that indications for implantation and type of pacemaker are comparable with other European countries

    Using Lightweight Activity Diagrams for Modeling and Generation of Web Information Systems

    Full text link
    The development process of web information systems nowadays improved a lot regarding effectiveness and tool support, but still contains many redundant steps for similar tasks. In order to overcome this, we use a model-driven approach to specify a web information system in an agile way and generate a full- edged and runnable application from a set of models. The covered aspects of the system comprise data structure, page structure including view on data, page- and workflow within the system as well as overall application structure and user rights management. Appropriate tooling allows transforming these models to complete systems and thus gives us opportunity for a lightweight development process based on models. In this paper, we describe how we approach the page- and workflow aspect by using activity diagrams as part of the agile modeling approach MontiWIS. We give an overview of the defined syntax, describe the supported forms of action contents and finally explain how the behavior is realized in the generated application.Comment: 12 pages, 6 figure

    The IGF2 methylation score for adrenocortical cancer:an ENSAT validation study

    Get PDF
    Adrenocortical carcinoma (ACC) is diagnosed using the histopathological Weiss score (WS), but remains clinically elusive unless it has metastasized or grows locally invasive. Previously, we proposed the objective IGF2 methylation score as diagnostic tool for ACC. This multicenter European cohort study validates these findings. Patient and tumor characteristics were obtained from adrenocortical tumor patients. DNA was isolated from frozen specimens, where after DMR2, CTCF3, and H19 were py rosequenced. The predictive value of the methylation score for malignancy, defined by the WS or metastasis development, was assessed using receiver operating characteristic curves and logistic and Cox regression analyses. Seventy-six ACC patients and 118 patients with adrenocortical adenomas were included from seven centers. The methylation score and tumor size were independently associated with the pathological ACC diagnosis (OR 3.756 95% CI 2.224-6.343; OR 1.467 95% CI 1.202-1.792, respectively; Hosmer-Lemeshow test P = 0.903), with an area under the curve (AUC) of 0.957 (95% CI 0. 930-0.984). The methylation score alone resulted in an AUC of 0.910 (95% CI 0.8 66-0.952). Cox regression analysis revealed that the methylation score, WS and tumor size predicted development of metastases in univariate analysis. In multivariate analysis, only the WS predicted development of metastasis (OR 1.682 95% CI 1.285-2.202; P <0.001). In conclusion, we validated the high diagnostic accuracy of the IGF2 methylation score for diagnosing ACC in a multicenter European cohort study. Considering the known limitations of the WS, the objective IGF2 methylation score could potentially provide extra guidance on decisions on postoperative strategies in adrenocortical tumor patients

    Trends in service time of pacemakers in the Netherlands:A long-term nationwide follow-up study

    Get PDF
    Aims: After decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker. Methods: We reviewed data collected between 1984 and 2006 in the first national Dutch pacemaker registry. This registry covered 96% of all generators implanted. We analysed the time of and reason for explantation of pacemaker generators. A 7-year follow-up interval after first implantation and following replacements was used to analyse changes over time. Results: During 22 years of data collection, nearly 97,000 first pacemaker generators were implanted. A total of 27,937 (22.4%) generators were explanted within a mean of 6.3 (standard deviation 3.3) years. Reasons for approximately 60% of these explantations were ` end of life' of the pacemaker generator or elective system change. Complications or failures such as infections and recalls accounted for approximately 20% of the explantations. For the remaining 20%, the reasons for explantation had not been registered. Conclusion: Despite progress in technology, a substantial proportion of pacemaker generators is explanted before its expected service time, with one in five generators being replaced due to technical failures, infections or other complications. Furthermore, the time interval between pacemaker implantation and explantation due to normal 'end of life' (battery EOL) decreased. Infections continue to rank highly as a cause for pacing system replacement, despite all current preventive measures

    Integration of environmental assessment in a PLM context: a case study in luxury industry

    Get PDF
    Nowadays, the environment becomes a major issue in our society. It gives rise to regu-lations, market demand and stakeholder's pressure which are concerning companies. These latter have to reduce the negative impact of their new product by eco-design and adopting a continuous improvement for their existing product portfolio. To do so, environmental assessment system is needed. Life Cycle Assessment (LCA) is the most known and recognized. However, this method is complex, requires significant resources and a large amount of accurate data. We propose a methodology to connect a simplified LCA tool with PLM system and ERP to evaluate an entire product portfolio at any time. This will allow design teams to consider the environmental issues in early design phase and gives the companies a global vision of their product portfolio. This methodology is experimented with packaging products of luxury brand, using the Teamcenter PLM system and a Simplified LCA Too

    Intraoperative MET-receptor targeted fluorescent imaging and spectroscopy for lymph node detection in papillary thyroid cancer:novel diagnostic tools for more selective central lymph node compartment dissection

    Get PDF
    PURPOSE: Patients undergoing prophylactic central compartment dissection (PCLND) for papillary thyroid cancer (PTC) are often overtreated. This study aimed to determine if molecular fluorescence-guided imaging (MFGI) and spectroscopy can be useful for detecting PTC nodal metastases (NM) and to identify negative central compartments intraoperatively. METHODS: We used a data-driven prioritization strategy based on transcriptomic profiles of 97 primary PTCs and 80 normal thyroid tissues (NTT) to identify tumor-specific antigens for a clinically available near-infrared fluorescent tracer. Protein expression of the top prioritized antigen was immunohistochemically validated with a tissue microarray containing primary PTC (n = 741) and NTT (n = 108). Staining intensity was correlated with 10-year locoregional recurrence-free survival (LRFS). A phase 1 study (NCT03470259) with EMI-137, targeting MET, was conducted to evaluate safety, optimal dosage for detecting PTC NM with MFGI, feasibility of NM detection with quantitative fiber-optic spectroscopy, and selective binding of EMI-137 for MET. RESULTS: MET was selected as the most promising antigen. A worse LRFS was observed in patients with positive versus negative MET staining (81.9% versus 93.2%; p = 0.02). In 19 patients, no adverse events related to EMI-137 occurred. 0.13 mg/kg EMI-137 was selected as optimal dosage for differentiating NM from normal lymph nodes using MFGI (p < 0.0001) and spectroscopy (p < 0.0001). MFGI identified 5/19 levels (26.3%) without NM. EMI-137 binds selectively to MET. CONCLUSION: MET is overexpressed in PTC and associated with increased locoregional recurrence rates. Perioperative administration of EMI-137 is safe and facilitates NM detection using MFGI and spectroscopy, potentially reducing the number of negative PCLNDs with more than 25%. CLINICAL TRIAL REGISTRATION: NCT03470259

    Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands: An expert consensus report of the Netherlands Society of Cardiology

    Get PDF
    Remote monitoring of cardiac implanted electronic devices (CIED: pacemaker, cardiac resynchronisation therapy device and implantable cardioverter defibrillator) has been developed for technical control and follow-up using transtelephonic data transmission. In addition, automatic or patient-triggered alerts are sent to the cardiologist or allied professional who can respond if necessary with various interventions. The advantage of remote monitoring appears obvious in impending CIED failures and suspected symptoms but is less likely in routine follow-up of CIED. For this follow-up the indications, quality of care, cost-effectiveneness and patient satisfaction have to be determined before remote CIED monitoring can be applied in daily practice. Nevertheless remote CIED monitoring is expanding rapidly in the Netherlands without professional agreements about methodology, responsibilities of all the parties involved and that of the device patient, and reimbursement. The purpose of this consensus document on remote CIED monitoring and follow-up is to lay the base for a nationwide, uniform implementation in the Netherlands. This report describes the technical communication, current indications, benefits and limitations of remote CIED monitoring and follow-up, the role of the patient and device manufacturer, and costs and reimbursement. The view of cardiology experts and of other disciplines in conjunction with literature was incorporated in a preliminary series of recommendations. In addition, an overview of the questions related to remote CIED monitoring that need to be answered is given. This consensus document can be used for future guidelines for the Dutch profession
    • …
    corecore