8 research outputs found

    Novel Ex Vivo DOAC Removal Methods Reduce Interference in Lupus Anticoagulant Testing

    Get PDF
    Direct oral anticoagulants (DOAC) interfere in laboratory coagulation testing. The aim here was to study how commercial DOAC removal methods, DOAC Filter® and DOAC-Stop™, perform to eliminate DOAC concentrations and false positive results in lupus anticoagulant (LAC) testing. We acquired 50 patient samples with high concentrations of DOACs: apixaban (n = 18, range 68–572 ng/mL), dabigatran (n = 8, range 47–154 ng/mL), edoxaban (n = 8, range 35–580 ng/mL) and rivaroxaban (n = 16, range 69–285 ng/mL). DOACs were removed ex vivo with either DOAC Filter® (n = 28) or DOAC-Stop™ (n = 22). Additionally, commercial control and calibrator samples were studied (n = 13 for DOAC Filter®, n = 14 for DOAC-Stop™). LAC screening was performed before and after DOAC removal. Both DOAC Filter® and DOAC-Stop™ were effective in removing DOAC concentrations in samples: DOAC concentrations decreased to median of 0 ng/mL (range 0–48 ng/mL). Only one sample had more than residual 25 ng/mL of DOAC (apixaban). Before DOAC removal, 96% (48/50) of patient samples and over 90% (12/13 DOAC Filter®, 13/14 DOAC-Stop™) of control/calibrator samples were positive in the LAC screening. In patient samples, LAC screening turned negative in 61% (17/28) after DOAC Filter® and 45% (10/22) after DOAC-Stop™ treatment. All control samples became negative after DOAC removal. In conclusion, DOAC removal ex vivo reduces false positives in LAC screening. DOAC removal halved the need for confirmation or mixing tests- Although a subset of patients would require further testing, DOAC removal reduces unnecessary repeated LAC testing

    Warfarin dose requirement in patients having severe thrombosis or thrombophilia

    Get PDF
    Aims Warfarin dose requirement varies significantly. We compared the clinically established doses based on international normalized ratio (INR) among patients with severe thrombosis and/or thrombophilia with estimates from genetic dosing algorithms. Methods Fifty patients with severe thrombosis and/or thrombophilia requiring permanent anticoagulation, referred to the Helsinki University Hospital Coagulation Center, were screened for thrombophilias and genotyped for CYP2C9*2 (c.430C>T, rs1799853), CYP2C9*3 (c.1075A>C, rs1057910) and VKORC1 c.-1639G>A (rs9923231) variants. The warfarin maintenance doses (target INR 2.0-3.0 in 94%, 2.5-3.5 in 6%) were estimated by the Gage and the International Warfarin Pharmacogenetics Consortium (IWPC) algorithms. The individual warfarin maintenance dose was tailored, supplementing estimates with comprehensive clinical evaluation and INR data. Results Mean patient age was 47 years (range 20-76), and BMI 27 (SD 6), 68% being women. Forty-six (92%) had previous venous or arterial thrombosis, and 26 (52%) had a thrombophilia, with 22% having concurrent aspirin. A total of 40% carried the CYP2C9*2 or *3 allele and 54% carried the VKORC1-1639A allele. The daily mean maintenance dose of warfarin estimated by the Gage algorithm was 5.4 mg (95% CI 4.9-5.9 mg), and by the IWPC algorithm was 5.2 mg (95% CI 4.7-5.7 mg). The daily warfarin maintenance dose after clinical visits and follow-up was higher than the estimates, mean 6.9 mg (95% CI 5.6-8.2 mg, P <0.006), with highest dose in patients having multiple thrombophilic factors (P <0.03). Conclusions In severe thrombosis and/or thrombophilia, variation in thrombin generation and pharmacodynamics influences warfarin response. Pharmacogenetic dosing algorithms seem to underestimate dose requirement.Peer reviewe

    Anaemia and enhancement of coagulation are associated with severe COVID-19 infection

    Get PDF
    Coagulation disturbances are common in severe COVID-19 infection. We examined laboratory markers in COVID-19 patients during the first wave of the pandemic in Finland. We analysed a wide panel of coagulation tests (IL ACL TOP 750/500) from anonymously collected samples of 78 hospitalized COVID-19 patients in intensive care units (ICUs; n = 34) or medical wards (n = 44) at Helsinki University Hospital in April-May 2020. These coagulation data were supplemented with the laboratory information system results, including complete blood count and C reactive protein (CRP). Coagulation and inflammatory markers were elevated in most: FVIII in 52%, fibrinogen 77%, D-dimer 74%, CRP 94%, platelet count 37%. Anaemia was common, especially in men (73% vs. 44% in women), and overall weakly correlated with FVIII (women R-2 = 0.48, men R-2 = 0.24). ICU patients had higher fibrinogen and D-dimer levels (p < .01). Men admitted to the ICU also had higher platelet count, leukocytes and FVIII and lower haemoglobin than the non-ICU patients. None of the patients met the disseminated intravascular coagulation (DIC) criteria, but 31% had a D-dimer level of at least 1.5 mg/L. Presence of both anaemia and high D-dimer together with FVIII is independently associated with ICU admission. Antithrombin was reduced in 47% of the patients but did not distinguish severity. Overall, CRP was associated with coagulation activation. Elevated FVIII, fibrinogen and D-dimer reflected a strong inflammatory response and were characteristic of hospitalized COVID-19 patients. The patients were often anaemic, as is typical in severe inflammation, while anaemia was also associated with coagulation activity.Peer reviewe

    Anticoagulated patients exhibit intact endogenous thrombin potential using ST Genesia unlike the Calibrated Automated Thrombogram

    Get PDF
    Background: The thrombin generation (TG) assay is a feasible but labor-intensive method for detecting global coagulation. It enables comprehensive assessment of anticoagulation, while drug-specific assays assess only exposure. Traditionally, the Calibrated Automated Thrombogram (CAT) has been used, however the ST Genesia (Diagnostica Stago) allows automated evaluation. Objective: We aimed to observe coagulation using the ST Genesia and compare the data with those of CAT in anticoagulated patients. Patients and methods: In total, 43 frozen-thawed samples were studied using DrugScreen to assess direct oral anticoagulants (DOACs), warfarin, and low-molecularweight heparin. Twenty samples (nine rivaroxaban, five apixaban, three warfarin, and three heparin) were also compared using CAT (5 pM tissue factor). Results: TG reduction in DrugScreen depended on the specific drug and modestly correlated with DOAC levels (lag time R-2 = 0.36; peak R-2 = 0.50). The best correlation was observed with peak thrombin and rivaroxaban-specified anti-activated factor X (anti-Xa) activity (R-2 = 0.60). When comparing ST Genesia with CAT, only the results for apixaban concorded (R-2 = 0.97). Unlike CAT, ST Genesia yielded a normal endogenous thrombin potential (ETP) in 77% (24/31) activated factor X inhibitor cases, and it failed to give readouts at international normalized ratio (INR) >= 4.5 and at anti-Xa >= 1.0 IU/mL. Conclusion: The ST Genesia data did not correlate with CAT, but it was independently associated with INR, anti-Xa, and DOAC concentrations. The lag time and peak responses were similar; the major differences were that ST Genesia showed no ETP effect of DOACs and failed to give readout at high INR or anti-Xa activity.Peer reviewe

    Effects of thromboprophylactic doses of apixaban and rivaroxaban on coagulation and thrombin generation in association with total hip replacement

    Get PDF
    Factor Xa inhibitors (FXaI) apixaban and rivaroxaban are used for thromboprophylaxis after major elective orthopaedic surgery. Because few patient sample studies exist, we postoperatively assessed patients undergoing unilateral total hip arthroplasty, including 22 treated with apixaban (2.5 mg BID) and 20 treated with rivaroxaban (10 mg OD). We collected blood samples before and 3 h after drug intake at 4 time points, preoperatively, as well as on day 1, week 1 (day 2-8) and day 28 post-operation. APTT and PT were immediately analysed. Calibrated anti-FXa activity, Russel's Viper Venom Time (RVVT) and thrombin generation (TG; Calibrated Automated Thrombogram(A (R))) captured the effects of FXaI on coagulation and TG. APTT and PT remained within the reference interval throughout, and did not correlate with FXaI levels (PT R-2 = 0.44, APTT R-2 = 0.07). Mean apixaban concentration at the peak varied by eightfold (19-153 ng/mL), but rivaroxaban only by 1.5-fold (111-183 ng/mL). Rivaroxaban, but not apixaban prolonged RVVT at peak levels. Both FXaIs had a prolonged lag time of TG (p <0.001). Rivaroxaban decreased ETP peak at all time points and reached a minimum at day 28 (540 nM/min at rivaroxaban 184 ng/mL, p <0.001), while rivaroxaban trough levels were low and ETP values normal. However, with apixaban, after an initial decrease, ETP did not differ between peak and trough levels until decreasing on day 28 at peak (990 nM/min at apixaban 112 ng/mL, p = 0.005). In conclusion, due to different dosing and pharmacology rivaroxaban and apixaban distinctly inhibited TG under postoperative conditions.Peer reviewe

    Reproducibility of fluorescent expression from engineered biological constructs in E. coli

    No full text
    We present results of the first large-scale interlaboratory study carried out in synthetic biology, as part of the 2014 and 2015 International Genetically Engineered Machine (iGEM) competitions. Participants at 88 institutions around the world measured fluorescence from three engineered constitutive constructs in E. coli. Few participants were able to measure absolute fluorescence, so data was analyzed in terms of ratios. Precision was strongly related to fluorescent strength, ranging from 1.54-fold standard deviation for the ratio between strong promoters to 5.75-fold for the ratio between the strongest and weakest promoter, and while host strain did not affect expression ratios, choice of instrument did. This result shows that high quantitative precision and reproducibility of results is possible, while at the same time indicating areas needing improved laboratory practices.Peer reviewe
    corecore