    Mind the gaps! Clinical and technical aspects of PCL-retaining total knee replacement with the balanced gap technique.

    Get PDF
    Contains fulltext : 83220.pdf (publisher's version ) (Open Access)25 januari 2011Promotor : Verdonschot, N.J.J. Co-promotores : Wymenga, A.B., Keijsers, N.L.W.239 p

    Effect of local anesthetic concentration, dose and volume on the duration of single-injection ultrasound-guided axillary brachial plexus block with mepivacaine: a randomized controlled trial

    Get PDF
    Contains fulltext : 152159.pdf (publisher's version ) (Open Access)BACKGROUND: In what way volume, concentration and dose affect block duration is controversial. The purpose of the present study is to investigate the effect of dose, volume and concentration of mepivacaine on the duration of sensory and motor blockade in ultrasound-guided single shot axillary brachial plexus blockade. METHODS: In this parallel group randomized trial conducted in the Sint Maartenskliniek Nijmegen, 45 adult patients undergoing minor orthopaedic forearm, wrist or hand surgery were randomized to 3 groups. Group A: 20 mL mepivacaine 1.5 %, Group B: 30 mL mepivacaine 1 % and Group C: 30 mL mepivacaine 1.5 %. Randomization was computer-generated, with allocation concealment by opaque sequentially numbered sealed envelopes. Patients and observers were blinded to group allocation. PRIMARY OUTCOME MEASURE: duration of sensory block. RESULTS: Forty-five patients were randomized, four patients were excluded and replaced, and 15 patients in each group were included in the analysis. Mean (95 % CI) sensory and motor block duration was 256 (230-282) and 254 (226-282) minutes in Group A, 226 (209-243) and 220 (200-240) minutes in Group B and 270 (249-291) and 264 (244-284) minutes in Group C. Duration of sensory and motor block duration differed significantly between groups (p = 0.012 and p = 0.016 respectively). Post-hoc analysis showed a significantly reduced sensory and motor block duration in Group B when compared to Group C of 44 min. No local anesthetic systemic toxicity was reported. CONCLUSIONS: When using mepivacaine for axillary brachial plexus block, a higher dose and concentration was associated with a longer duration of sensory and motor blockade, but not a higher volume. TRIAL REGISTRATION: The Netherlands National Trial Register NTR3648 . Registered October 3, 2012.8 p

    In vivo knee laxity in flexion and extension: a radiographic study in 30 older healthy subjects.

    No full text
    Contains fulltext : 69774.pdf (publisher's version ) (Closed access)In order to determine how "tight" a total knee prosthesis should be implanted, it is important to know the amount of laxity in a healthy knee. The objective of this study was to determine knee laxity in extension and flexion in healthy, non-arthritic knees of subjects similar in age to patients undergoing a total knee arthroplasty and to provide guidelines for the orthopaedic surgeon in his attempt to restore the stability of an osteoarthritic knee to normal. Thirty healthy subjects (15 male, 15 female), mean age 62 (SD 6.4) years, were included in the study. For each subject one, randomly selected, knee was stressed in extension and in 70 degrees flexion (15 Nm). Varus and valgus laxity were measured on radiographs. The passive range of motion and active flexion was assessed. Mean valgus laxity in extension was 2.3 degrees (SD 0.9, range 0.2 degrees -4.1 degrees ). In extension mean varus laxity was 2.8 degrees (SD 1.3, range 0.6 degrees -5.4 degrees ). In flexion, mean valgus laxity was 2.5 degrees (SD 1.5, range 0.0 degrees -6.0 degrees ) and mean varus laxity was 3.1 degrees (SD 2.0, range 0.1 degrees -7.0 degrees ). Varus and valgus knee laxity in extension and in flexion were comparable. This study shows that the normal knee in this age group has an inherent degree of varus-valgus laxity. Whether the results of the present study can be used to optimise the total knee arthroplasty implantation technique requires further investigation

    Mechanical Stability of the Prodisc-C Vivo Cervical Disc Arthroplasty: A Preliminary, Observational Study Using Radiostereometric Analysis

    No full text
    Contains fulltext : 220943.pdf (publisher's version ) (Open Access)STUDY DESIGN: Prospective cohort study. OBJECTIVE: To investigate the primary stability of the Prodisc-C Vivo cervical disc arthroplasty with regard to the adjacent cervical vertebrae using radiostereometric analysis (RSA), and to monitor its clinical performance. METHODS: Sixteen patients with degenerative cervical disc disease were included. RSA radiographs were obtained at the first postoperative day, at 6 weeks, 3 months, and 6 months postoperatively. Migration (translation [mm]) of the superior and inferior implant components were measured with model-based RSA, expressed along the 3 orthogonal axes, and calculated as total translation. Clinical outcomes were Neck Disability Index, numeric rating scales for neck and arm pain, Likert-type scales for satisfaction, and adverse events. Range of motion was reported as C2-C7 flexion-extension mobility (ROM). RESULTS: At final follow-up, no significant increase over time in median total translation was found. One inferior and 3 superior components subsided but were asymptomatic. ROM remained stable and clinical outcomes improved over time. Although 3 patients were unsatisfied and 3 adverse events occurred, this was not related to translation of the components. CONCLUSIONS: On a group level, both components of the Prodisc-C Vivo cervical disc arthroplasty remained stable over time and below the clinical threshold of 1 mm. Individual outliers for translation were not clinically relevant and probably related to settling of the components into the vertebral endplates. RSA allowed us to perform a preliminary but accurate study on the micromotion of a new cervical disc replacement in a small sample size, without putting large numbers of patients at risk

    Revision for coronal malalignment will improve functional outcome up to 5 years postoperatively

    No full text
    PURPOSE: Revision of a total knee arthroplasty (TKA) for the diagnosis of malalignment is widely performed. However, very little is known about the functional outcome in revision TKA surgery for malalignment. The aim of this study was to assess the functional outcome and to identify factors influencing the functional outcome of patients who have had a revision of a TKA for the diagnosis of malalignment at 5 years follow-up. METHODS: All patients with a revision of a TKA for malalignment as the primary reason were selected from a prospective database. The diagnosis of symptomatic malalignment was made by the surgeon and quantified by radiologic examination. Functional outcome was scored by the functional score of the Knee Society Clinical Rating System (fKSS) at 0, 12, 24 and 60 months. Multiple imputation for missing data and multivariable analysis were performed to identify factors influencing functional outcome. RESULTS: After selection, 105 patients (age: 65.1 ± 9.1 years, gender M:F 30:75) were eligible for outcome analysis. Functional outcome significantly improved from the preoperative (fKSS: 44.1 ± 22.0) to 5 years postoperative (64.7 ± 24.0, p < 0.001) time frames. Higher degree of coronal deviation, younger age and lower preoperative KSS were found to be strongest positive influencing factors for the change in fKSS. CONCLUSION: Revision of TKA for malalignment appears to be an effective treatment to improve functional outcome up to 5 years postoperatively. Higher degree of coronal deviation, younger age and lower preoperative KSS are the strongest contributing factors for functional improvement. LEVEL OF EVIDENCE: Level III; Therapeutic prospective cohort study

    Numerical analysis of variations in posterior cruciate ligament properties and balancing techniques on total knee arthroplasty loading.

    Get PDF
    Contains fulltext : 87213.pdf (publisher's version ) (Closed access)Total knee arthroplasty (TKA) is a widely used and successful orthopaedic procedure. During TKA, the posterior cruciate ligament (PCL) can either be retained or substituted by a post-cam mechanism. One of the main functions of the PCL is to facilitate femoral rollback during knee flexion. For adequate PCL functioning, the PCL should be balanced correctly after TKA. A tight PCL leads to more femoral rollback at the expense of a higher joint compression and potential polyethylene wear. Frequently used surgical techniques to balance a tight PCL are PCL release and increasing the posterior tibial slope. The objective of this study was to evaluate the effects of variations in PCL properties and balancing techniques on the mechanical outcome of a total knee replacement during a weight-bearing squatting movement (flexion range=45-150 degrees). For this purpose, a prosthetic finite element knee model was developed including a PCL having adjustable properties. Varying the PCL stiffness and PCL steepness (elevation angle) with respect to the tibial plateau considerably affected the TKA loading characteristics. Both a relatively high PCL stiffness and a low elevation angle at the start of the flexion cycle led to a high PCL force (1400-1500 N) and a high peak polyethylene contact stress of roughly 52 MPa during deeper knee flexion (120 degrees). Releasing the PCL with roughly 4 mm or increasing the posterior tibial slope to 7 degrees reduced the PCL force to 300-400 N and the polyethylene peak contact stress to 35-42 MPa at 120 degrees of flexion. The femoral rollback patterns during deep knee flexion were only marginally affected when extra posterior tibial slope was added, whereas additional PCL release resulted in paradoxical anterior movement of the femur.1 september 20108 p

    Biomechanical evaluation of three different fixation methods of the Chevron osteotomy of the olecranon: an analysis with Roentgen Stereophotogrammatic Analysis

    Get PDF
    Item does not contain fulltextBACKGROUND: In this study three different methods for fixating the Chevron osteotomy of the olecranon are evaluated. Transcortical fixed Kirschner wires with a tension band, a large cancellous screw with a tension band, and a large cancellous screw alone are compared using Roentgen Stereophotogrammatic Analysis (RSA). METHODS: The different fixation methods were tested in 17 cadaver specimens by applying increasing repetitive force to the triceps tendon. Forces applied were 200N, 350N, and 500N. Translation and rotation of the osteotomy were recorded using Roentgen Stereophotogrammatic Analysis. FINDINGS: Both the fixations with a cancellous screw with tension band and with bi-cortical placed Kirschner wires with a tension band provide enough stability to withstand the forces of normal daily use. INTERPRETATION: Since fixation with a cancellous screw with tension band is a fast and easy method and is related to minimal soft tissue damage this method can preferably be used for fixation of a Chevron osteotomy of the olecranon.5 p

    Definitions of poor outcome after total knee arthroplasty: an inventory review

    No full text
    Contains fulltext : 220896.pdf (publisher's version ) (Open Access)BACKGROUND: A significant proportion of patients experiences poor response (i.e. no or little improvement) after total knee arthroplasty (TKA) because of osteoarthritis. It is difficult to quantify the proportion of patients who experiences poor response to TKA, as different definitions of, and perspectives (clinician's and patient's) on poor response are being used. The aim of this study was therefore to review the literature and summarize definitions of poor response to TKA. METHODS: A systematic search was performed to identify and review studies that included dichotomous definitions of poor outcome after primary TKA. The type, amount and combination of domains (e.g. functioning), outcome measures, type of thresholds (absolute/relative, change/cut-off), values and moments of follow-up used in definitions were summarized. RESULTS: A total of 47 different dichotomous definitions of poor response to TKA were extracted from 2163 initially identified studies. Thirty-six definitions incorporated one domain, seven definitions comprised two domains and four definitions comprised three domains. Eight different domains were used in identified definitions: pain, function, physical functioning, quality of life (QoL), patient satisfaction, anxiety, depression and patient global assessment. The absolute cut-off value was the most common type of threshold, with large variety in value and timing of follow-up. CONCLUSIONS: Our inventory review shows that definitions of poor response to TKA are heterogeneous. Our findings stresses the need for an unambiguous definition of poor response to draw conclusions about the prevalence of poor-responders to TKA across hospitals and countries, and to identify patients at risk

    Limited effect of anatomical insert geometry on in vitro laxity in balanced anatomic posterior cruciate ligament retaining total knee arthroplasty

    No full text
    PURPOSE: The present study assessed the effect of insert articular surface geometry (anatomical versus conventional insert design) on anteroposterior (AP) translation and varus-valgus (VV) laxity in balanced posterior cruciate ligament (PCL) retaining total knee arthroplasty (TKA). Secondly, we evaluated if the AP translation and VV laxity in the reconstructed knee resembled the stability of the native knee. METHODS: Nine fresh-frozen full-leg cadaver specimens were used in this study. After testing the native knee, anatomical components of a PCL-retaining implant were implanted. The knee joints were subjected to anteriorly and posteriorly directed forces (at 20° and 90° flexion) and varus-valgus stresses (at 20°, 45° and 90° flexion) in both non-weightbearing and weightbearing situations in a knee kinematics simulator. Measurements were performed in the native knee, TKA with anatomical insert geometry (3° built-in varus, medial concave, lateral convex), and TKA with symmetrical insert geometry. RESULTS: In weightbearing conditions, anterior translations ranged between 2.6 and 3.9 mm at 20° flexion and were < 1 mm at 90° flexion. Posterior translation at 20° flexion was 2.7 mm for the native knee versus 4.0 mm (p = 0.047) and 7.0 mm (p = 0.02) for the symmetrical insert and the anatomical insert, respectively. Posterior translation at 90° flexion was < 1.1 mm and not significantly different between the native knee and insert types. In non-weightbearing conditions, the anterior translation at 20° flexion was 5.9 mm for the symmetrical and 4.6 mm for the anatomical insert (n.s.), compared with 3.0 mm for the native knee (p = 0.02). The anterior translation at 90° flexion was significantly higher for the reconstructed knees (anatomical insert 7.0 mm; symmetrical insert 9.2 mm), compared with 1.6 mm for the native knee (both p = 0.02). Varus-valgus laxity at different flexion angles was independent of insert geometry. A valgus force in weightbearing conditions led to significantly more medial laxity (1°-3° opening) in the native knee at 45° and 90° flexion compared with the reconstructed knee for all flexion angles. CONCLUSIONS: Insert geometry seems to have a limited effect with respect to AP translation and VV laxity, in the well-balanced PCL-retaining TKA with an anatomical femoral component. Secondly, AP translation and VV laxity in the reconstructed knee approximated the laxity of the native knee