137 research outputs found

    Internal consistency reliability is a poor predictor of responsiveness

    Get PDF
    BACKGROUND: Whether responsiveness represents a measurement property of health-related quality of life (HRQL) instruments that is distinct from reliability and validity is an issue of debate. We addressed the claims of a recent study, which suggested that investigators could rely on internal consistency to reflect instrument responsiveness. METHODS: 516 patients with chronic obstructive pulmonary disease or knee injury participating in four longitudinal studies completed generic and disease-specific HRQL questionnaires before and after an intervention that impacted on HRQL. We used Pearson correlation coefficients and linear regression to assess the relationship between internal consistency reliability (expressed as Cronbach's alpha), instrument type (generic and disease-specific) and responsiveness (expressed as the standardised response mean, SRM). RESULTS: Mean Cronbach's alpha was 0.83 (SD 0.08) and mean SRM was 0.59 (SD 0.33). The correlation between Cronbach's alpha and SRMs was 0.10 (95% CI -0.12 to 0.32) across all studies. Cronbach's alpha alone did not explain variability in SRMs (p = 0.59, r(2 )= 0.01) whereas the type of instrument was a strong predictor of the SRM (p = 0.012, r(2 )= 0.37). In multivariable models applied to individual studies Cronbach's alpha consistently failed to predict SRMs (regression coefficients between -0.45 and 1.58, p-values between 0.15 and 0.98) whereas the type of instrument did predict SRMs (regression coefficients between -0.25 to -0.59, p-values between <0.01 and 0.05). CONCLUSION: Investigators must look to data other than internal consistency reliability to select a responsive instrument for use as an outcome in clinical trials

    Elevated troponin and myocardial infarction in the intensive care unit: a prospective study

    Get PDF
    INTRODUCTION: Elevated troponin levels indicate myocardial injury but may occur in critically ill patients without evidence of myocardial ischemia. An elevated troponin alone cannot establish a diagnosis of myocardial infarction (MI), yet the optimal methods for diagnosing MI in the intensive care unit (ICU) are not established. The study objective was to estimate the frequency of MI using troponin T measurements, 12-lead electrocardiograms (ECGs) and echocardiography, and to examine the association of elevated troponin and MI with ICU and hospital mortality and length of stay. METHOD: In this 2-month single centre prospective cohort study, all consecutive patients admitted to our medical-surgical ICU were classified in duplicate by two investigators as having MI or no MI based on troponin, ECGs and echocardiograms obtained during the ICU stay. The diagnosis of MI was based on an adaptation of the joint European Society of Cardiology/American College of Cardiology definition: a typical rise or fall of an elevated troponin measurement, in addition to ischemic symptoms, ischemic ECG changes, a coronary artery intervention, or a new cardiac wall motion abnormality. RESULTS: We screened 117 ICU admissions and enrolled 115 predominantly medical patients. Of these, 93 (80.9%) had at least one ECG and one troponin; 44 of these 93 (47.3%) had at least one elevated troponin and 24 (25.8%) had an MI. Patients with MI had significantly higher mortality in the ICU (37.5% versus 17.6%; P = 0.050) and hospital (50.0% versus 22.0%; P = 0.010) than those without MI. After adjusting for Acute Physiology and Chronic Health Evaluation II score and need for inotropes or vasopressors, MI was an independent predictor of hospital mortality (odds ratio 3.22, 95% confidence interval 1.04–9.96). The presence of an elevated troponin (among those patients in whom troponin was measured) was not independently predictive of ICU or hospital mortality. CONCLUSION: In this study, 47% of critically ill patients had an elevated troponin but only 26% of these met criteria for MI. An elevated troponin without ischemic ECG changes was not associated with adverse outcomes; however, MI in the ICU setting was an independent predictor of hospital mortality

    Electronic nicotine delivery systems and/or electronic non-nicotine delivery systems for tobacco smoking cessation or reduction: a systematic review and meta-analysis

    Get PDF
    Objective A systematic review and meta-analysis to investigate the impact of electronic nicotine delivery systems (ENDS) and/or electronic non-nicotine delivery systems (ENNDS) versus no smoking cessation aid, or alternative smoking cessation aids, in cigarette smokers on long-term tobacco use. Data sources Searches of MEDLINE, EMBASE, PsycInfo, CINAHL, CENTRAL and Web of Science up to December 2015. Study selection Randomised controlled trials (RCTs) and prospective cohort studies. Data extraction Three pairs of reviewers independently screened potentially eligible articles, extracted data from included studies on populations, interventions and outcomes and assessed their risk of bias. We used the Grading of Recommendations Assessment, Development and Evaluation approach to rate overall certainty of the evidence by outcome. Data synthesis Three randomised trials including 1007 participants and nine cohorts including 13?115 participants proved eligible. Results provided by only two RCTs suggest a possible increase in tobacco smoking cessation with ENDS in comparison with ENNDS (RR 2.03, 95% CI 0.94 to 4.38; p=0.07; I2=0%, risk difference (RD) 64/1000 over 6 to 12?months, low-certainty evidence). Results from cohort studies suggested a possible reduction in quit rates with use of ENDS compared with no use of ENDS (OR 0.74, 95% CI 0.55 to 1.00; p=0.051; I2=56%, very low certainty). Conclusions There is very limited evidence regarding the impact of ENDS or ENNDS on tobacco smoking cessation, reduction or adverse effects: data from RCTs are of low certainty and observational studies of very low certainty. The limitations of the cohort studies led us to a rating of very low-certainty evidence from which no credible inferences can be drawn. Lack of usefulness with regard to address the question of e-cigarettes\u27 efficacy on smoking reduction and cessation was largely due to poor reporting. This review underlines the need to conduct well-designed trials measuring biochemically validated outcomes and adverse effects

    Re-evaluation of low intensity pulsed ultrasound in treatment of tibial fractures (TRUST): Randomized clinical trial

    Get PDF
    Objective: To determine whether low intensity pulsed ultrasound (LIPUS), compared with sham treatment, accelerates functional recovery and radiographic healing in patients with operatively managed tibial fractures. Design: A concealed, randomized, blinded, sham controlled clinical trial with a parallel group design of 501 patients, enrolled between October 2008 and September 2012, and followed for one year. Setting: 43 North American academic trauma centers. Participants: Skeletally mature men or women with an open or closed tibial fracture amenable to intramedullary nail fixation. Exclusions comprised pilon fractures, tibial shaft fractures that extended into the joint and required reduction, pathological fractures, bilateral tibial fractures, segmental fractures, spiral fractures \u3e7.5 cm in length, concomitant injuries that were likely to impair function for at least as long as the patient\u27s tibial fracture, and tibial fractures that showed 1 cm gap after surgical fixation. 3105 consecutive patients who underwent intramedullary nailing for tibial fracture were assessed, 599 were eligible and 501 provided informed consent and were enrolled. Interventions: Patients were allocated centrally to self administer daily LIPUS (n=250) or use a sham device (n=251) until their tibial fracture showed radiographic healing or until one year after intramedullary fixation. Main outcom e measures: Primary registry specified outcome was time to radiographic healing within one year of fixation; secondary outcome was rate of non-union. Additional protocol specified outcomes included short form-36 (SF-36) physical component summary (PCS) scores, return to work, return to household activities, return to ≥80% of function before injury, return to leisure activities, time to full weight bearing, scores on the health utilities index (mark 3), and adverse events related to the device. Results: SF-36 PCS data were acquired from 481/501 (96%) patients, for whom we had 2303/2886 (80%) observations, and radiographic healing data were acquired from 482/501 (96%) patients, of whom 82 were censored. Results showed no impact on SF-36 PCS scores between LIPUS and control groups (mean difference 0.55, 95% confidence interval -0.75 to 1.84; P=0.41) or for the interaction between time and treatment (P=0.30); minimal important difference is 3-5 points) or in other functional measures. There was also no difference in time to radiographic healing (hazard ratio 1.07, 95% confidence interval 0.86 to 1.34; P=0.55). There were no differences in safety outcomes between treatment groups. Patient compliance was moderate; 73% of patients administered ≥50% of all recommended treatments. Conclusions: Postoperative use of LIPUS after tibial fracture fixation does not accelerate radiographic healing and fails to improve functional recovery. Study registration: ClinicalTrialGov Identifier: NCT00667849

    Factors Associated With Mortality After Surgical Management of Femoral Neck Fractures

    Get PDF
    BACKGROUND: Hip fractures are recognized as one of the most devastating injuries impacting older adults because of the complications that follow. Mortality rates postsurgery can range from 14% to 58% within one year of fracture. We aimed to identify factors associated with increased risk of mortality within 24 months of a femoral neck fracture in patients aged ≥50 years enrolled in the FAITH and HEALTH trials. METHODS: Two multivariable Cox proportional hazards regressions were used to investigate potential prognostic factors that may be associated with mortality within 90 days and 24 months of hip fracture. RESULTS: Ninety-one (4.1%) and 304 (13.5%) of 2247 participants died within 90 days and 24 months of suffering a femoral neck fracture, respectively. Older age (P < 0.001), lower body mass index (P = 0.002), American Society of Anesthesiologists (ASA) class III/IV/V (P = 0.004), use of an ambulatory aid before femoral neck fracture (P < 0.001), and kidney disease (P < 0.001) were associated with a higher risk of mortality within 24 months of femoral neck fracture. Older age (P = 0.03), lower body mass index (P = 0.02), use of an ambulatory aid before femoral neck fracture (P < 0.001), and having a comorbidity (P = 0.04) were associated with a higher risk of mortality within 90 days of femoral neck fracture. CONCLUSIONS: Our analysis found that factors that are indicative of a poorer health status were associated with a higher risk of mortality within 24 months of femoral neck fracture. We did not find a difference in treatment methods (internal fixation vs. joint arthroplasty) on the risk of mortality. LEVEL OF EVIDENCE: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence

    Is Total Hip Arthroplasty a Cost-Effective Option for Management of Displaced Femoral Neck Fractures? A Trial-Based Analysis of the HEALTH Study

    Get PDF
    BACKGROUND: Displaced femoral neck fractures are a significant source of morbidity and mortality and can be treated with either hemiarthroplasty (HA) or total hip arthroplasty (THA). Proponents of THA have argued THA offers lower risk of revision, with improved functional outcomes when compared to HA. To evaluate cost effectiveness of THA compared with HA, a trial-based economic analysis of the HEALTH study was undertaken. METHODS: Health care resource utilization (HRU) and health-related quality of life (HRQoL) data were collected postoperatively and costed using publicly available databases. Using EuroQol-5 Dimensions (EQ-5D) scores, we derived quality adjusted life years (QALYs). A 1.5% discount rate to both costs and QALYs was applied. Age analyses per age group were conducted. All costs are reported in 2019 Canadian dollars. RESULTS: When compared with HA, THA was not cost-effective for all patients with displaced femoral neck fractures (150,000/QALYgained).Ifdecisionmakerswerewillingtospend150,000/QALY gained). If decision makers were willing to spend 50,000 or $100,000 to gain one QALY, the probability of THA being cost-effective was 12.8% and 32.8%, respectively. In a subgroup of patients younger than 73 (first quartile), THA was both more effective and less costly. Otherwise, THA was more expensive and yielded marginal HRQoL gains. CONCLUSIONS: Our results suggest that for most patients, THA is not a cost-effective treatment for displaced femoral neck fracture management versus HA. However, THA may be cost effective for younger patients. These patients experience more meaningful improvements in quality of life with less associated cost because of shorter hospital stay and fewer postoperative complications. LEVEL OF EVIDENCE: Economic Level II. See Instructions for Authors for a complete description of levels of evidence

    Total Hip Arthroplasty or Hemiarthroplasty for Hip Fracture.

    Get PDF
    BACKGROUND: Globally, hip fractures are among the top 10 causes of disability in adults. For displaced femoral neck fractures, there remains uncertainty regarding the effect of a total hip arthroplasty as compared with hemiarthroplasty. METHODS: We randomly assigned 1495 patients who were 50 years of age or older and had a displaced femoral neck fracture to undergo either total hip arthroplasty or hemiarthroplasty. All enrolled patients had been able to ambulate without the assistance of another person before the fracture occurred. The trial was conducted in 80 centers in 10 countries. The primary end point was a secondary hip procedure within 24 months of follow-up. Secondary end points included death, serious adverse events, hip-related complications, health-related quality of life, function, and overall health end points. RESULTS: The primary end point occurred in 57 of 718 patients (7.9%) who were randomly assigned to total hip arthroplasty and 60 of 723 patients (8.3%) who were randomly assigned to hemiarthroplasty (hazard ratio, 0.95; 95% confidence interval [CI], 0.64 to 1.40; P = 0.79). Hip instability or dislocation occurred in 34 patients (4.7%) assigned to total hip arthroplasty and 17 patients (2.4%) assigned to hemiarthroplasty (hazard ratio, 2.00; 99% CI, 0.97 to 4.09). Function, as measured with the total Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score, pain score, stiffness score, and function score, modestly favored total hip arthroplasty over hemiarthroplasty. Mortality was similar in the two treatment groups (14.3% among the patients assigned to total hip arthroplasty and 13.1% among those assigned to hemiarthroplasty, P = 0.48). Serious adverse events occurred in 300 patients (41.8%) assigned to total hip arthroplasty and in 265 patients (36.7%) assigned to hemiarthroplasty. CONCLUSIONS: Among independently ambulating patients with displaced femoral neck fractures, the incidence of secondary procedures did not differ significantly between patients who were randomly assigned to undergo total hip arthroplasty and those who were assigned to undergo hemiarthroplasty, and total hip arthroplasty provided a clinically unimportant improvement over hemiarthroplasty in function and quality of life over 24 months. (Funded by the Canadian Institutes of Health Research and others; ClinicalTrials.gov number, NCT00556842.)

    What Factors Increase Revision Surgery Risk When Treating Displaced Femoral Neck Fractures With Arthroplasty: A Secondary Analysis of the HEALTH Trial

    Get PDF
    OBJECTIVES: HEALTH was a randomized controlled trial comparing total hip arthroplasty with hemiarthroplasty in low-energy displaced femoral neck fracture patients aged ≥50 years with unplanned revision surgery within 24 months of the initial procedure being the primary outcome. No significant short-term differences between treatment arms were observed. The primary objective of this secondary HEALTH trial analysis was to determine if any patient and surgical factors were associated with increased risk of revision surgery within 24 months after hip fracture. METHODS: We analyzed 9 potential factors chosen a priori that could be associated with revision surgery. The factors included age, body mass index, major comorbidities, independent ambulation, type of surgical approach, length of operation, use of femoral cement, femoral head size, and degree of femoral stem offset. Our statistical analysis was a multivariable Cox regression using reoperation within 24 months of index surgery as the dependent variable. RESULTS: Of the 1441 patients included in this analysis, 8.1% (117/1441) experienced reoperation within 24 months. None of the studied factors were found to be predictors of revision surgery (P > 0.05). CONCLUSION: Both total and partial hip replacements are successful procedures in low-energy displaced femoral neck fracture patients. We were unable to identify any patient or surgeon-controlled factors that significantly increased the need for revision surgery in our elderly and predominately female patient population. One should not generalize our findings to an active physiologically younger femoral neck fracture population. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence

    Predictors of Long-Term Pain After Hip Arthroplasty in Patients With Femoral Neck Fractures: A Cohort Study

    Get PDF
    OBJECTIVES: To identify factors associated with the development of prolonged pain after hip fracture surgery. DESIGN: Secondary analysis of a randomized controlled trial. SETTING: Eighty hospitals in 10 countries. PATIENTS/PARTICIPANTS: One thousand four hundred forty-one hip fracture patients in the HEALTH trial. INTERVENTIONS: Total hip arthroplasty or hemiarthroplasty. MAIN OUTCOME MEASURES: Moderate-to-severe pain (at least 2 activities on the Western Ontario and McMaster Universities Osteoarthritis questionnaire pain subscale with scores ≥2) at 12 and 24 months after hip arthroplasty. RESULTS: Of 840 and 726 patients with complete baseline data and outcomes at 1-year and 2-year follow-up, 96 (11.4%) and 80 (11.0%) reported moderate-to-severe pain, respectively. An increased risk of pain at both 1 and 2 years after surgery was associated with reporting moderate-to-severe hip pain before fracture [absolute risk increase (ARI) 15.3%, 95% confidence interval (CI) 6.44%-24.35%; ARI 12.5%, 95% CI 2.85%-22.12%, respectively] and prefracture opioid use (ARI 15.6%, 95% CI 5.41%-25.89%; ARI 21.1%; 95% CI 8.23%-34.02%, respectively). Female sex was associated with an increased risk of persistent pain at 1 year (ARI 6.2%, 95% CI 3.53%-8.84%). A greater risk of persistent pain at 2 years was associated with younger age (≤79-year-old; ARI 6.3%; 95% CI 2.67%-9.91%) and higher prefacture functional status (ARI 10.7%; 95% CI 3.80%-17.64%). CONCLUSIONS: Among hip fracture patients undergoing arthroplasty, approximately one in 10 will experience moderate-to-severe pain up to 2 years after surgery. Younger age, female sex, higher functioning prefracture, living with hip pain prefracture, and use of prescription opioids were predictive of persistent pain. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence
    corecore