6,024 research outputs found

    Technology Integration Professional Development for Teachers: Strategies for Action

    Get PDF
    The purpose of this project was to present a comprehensive set of strategies for principals and school administrators to utilize for the management of professional development related to technology integration. The ability to effectively use educational technologies in teaching is becoming an increasingly important skill for teachers to possess. Through a presentation of the current research, this researcher has built a case for technology related professional development using the available technology integration data, teacher opinions and the commentary of other educational research professionals. To further support this subject as a topic for professional development, this researcher has presented a sample of the current research that demonstrates its effectiveness for teacher practice. Additionally, this author presents a sample of the technology related professional development programs and their results. The culminating product of this research is delivered in the form of a Microsoft PowerPoint presentation

    Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release

    Get PDF
    Implantation using stainless steels (SS) is an example where an understanding of protein-induced metal release from SS is important when assessing potential toxicological risks. Here, the protein-induced metal release was investigated for austenitic (AISI 304, 310, and 316L), ferritic (AISI 430), and duplex (AISI 2205) grades in a phosphate buffered saline (PBS, pH 7.4) solution containing either bovine serum albumin (BSA) or lysozyme (LSZ). The results show that both BSA and LSZ induce a significant enrichment of chromium in the surface oxide of all stainless steel grades. Both proteins induced an enhanced extent of released iron, chromium, nickel and manganese, very significant in the case of BSA (up to 40-fold increase), whereas both proteins reduced the corrosion resistance of SS, with the reverse situation for iron metal (reduced corrosion rates and reduced metal release in the presence of proteins). A full monolayer coverage is necessary to induce the effects observed. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10856-013-4859-8) contains supplementary material, which is available to authorized users

    Simulation of off-energy electron background in DELPHI

    Get PDF
    Monte Carlo simulations of off-energy electron background in the DELPHI luminometer STIC are reported. The study simulates the running conditions at 68 GeV with and without bunch trains. The electrostatic separators, which create the vertical separation bumps for the the bunch trains, cause a high concentration of background in the vertical plane. The simulations are compared to LEP data taken under similar running conditions. A comparison between the simulated running conditions at 68 GeV and those of the new LEP2 beam optics at 80.5 GeV is made. Moreover, the study investigates background components entering STIC elsewhere that through the front of the detector, and a significant portion is found to enter either from the back or from below. Possible improvements of the background situation are also discussed

    A randomized controlled trial of the impact of body-worn camera activation on the outcomes of individual incidents

    Get PDF
    Objectives Evaluate the impact of body-worn cameras (BWCs) on officer-initiated activity, arrests, use of force, and complaints. Methods We use instrumental variable analysis to examine the impact of BWC assignment and BWC activation on the outcomes of individual incidents through a randomized controlled trial of 436 officers in the Phoenix Police Department. Results Incidents involving BWC activations were associated with a lower likelihood of officer-initiated contacts and complaints, but a greater likelihood of arrests and use of force. BWC assignment alone was unrelated to arrests or complaints; however, incidents involving officers who were assigned and activated their BWC were significantly more likely to result in an arrest and less likely to result in a complaint. Conclusions Future researchers should account for BWC activation to better estimate the effects of BWCs on officer behavior. To maximize the effects of BWCs, police agencies should ensure that officers are complying with activation policies

    Contribution of residential wood combustion to hourly winter aerosol in Northern Sweden determined by positive matrix factorization

    No full text
    International audienceThe combined effect of residential wood combustion (RWC) emissions with stable atmospheric conditions, which is a frequent occurrence in Northern Sweden during wintertime, can deteriorate the air quality even in small towns. To estimate the contribution of RWC to the total atmospheric aerosol loading, the positive matrix factorization (PMF) method was applied to hourly mean particle number size distributions measured in a residential area in Lycksele during winter 2005/2006. The sources were identified based on the particle number size distribution profiles of the PMF factors, the diurnal contributions patterns estimated by PMF for both weekends and weekdays, and correlation of the modeled particle number concentration per factor with measured aerosol mass concentrations (PM10, PM1, and light-absorbing carbon MLAC). Through these analyses, the factors were identified as local traffic (factor 1), local RWC (factor 2), and local RWC plus long-range transport (LRT) of aerosols (factor 3). In some occasions, it was difficult to detach the contributions of local RWC from background concentrations since their particle number size distributions partially overlapped and the model was not able to separate these two sources. As a consequence, we report the contribution of RWC as a range of values, being the minimum determined by factor 2 and the possible maximum as the contributions of both factors 2 and 3. A multiple linear regression (MLR) of observed PM10, PM1, total particle number, and MLAC concentrations is carried out to determine the source contribution to these aerosol variables. The results reveal RWC is an important source of atmospheric particles in the size range 25?606 nm (44?57%), PM10 (36?82%), PM1 (31?83%), and MLAC (40?76%) mass concentrations in the winter season. The contribution from RWC is especially large on weekends between 18:00 LT and midnight whereas local traffic emissions show similar contributions every day

    Attitudinal Changes Toward Body-Worn Cameras: Perceptions of Cameras, Organizational Justice, and Procedural Justice Among Volunteer and Mandated Officers

    Get PDF
    Little is known about officer perceptions of body-worn cameras (BWCs), and whether perceptions change following implementation within their agencies. BWC deployment varies, with some agencies mandating officers to wear BWCs and others using volunteers. Researchers have yet to assess attitudinal differences between volunteers and mandated officers. This study addresses these gaps using data from an evaluation of BWCs in the Phoenix Police Department to examine officer perceptions of the utility of BWCs, perceptions of organizational justice, and support for using procedural justice. We use inverse propensity weighted difference-in-difference models to examine changes in officer perceptions over time between randomly selected officers who were mandated to wear a BWC, BWC volunteers, officers who resisted BWCs, and control officers. We identified limited significant differences in perceptions of BWCs over time, though effect sizes suggest that BWC volunteers and mandated officers were more subdued in their expectations about BWCs at the posttest

    Evaluation of Innotrac Aio! Second-Generation Cardiac Troponin I Assay: The Main Characteristics for Routine Clinical Use

    Get PDF
    The availability of a simple, sensitive, and rapid test using whole blood to facilitate processing and to reduce the turnaround time could improve the management of patients presenting with chest pain. The aim of this study was an evaluation of the Innotrac Aio! second-generation cardiac troponin I (cTnI) assay. The Innotrac Aio! second-generation cTnI assay was compared with the Abbott AxSYM first-generation cTnI, Beckman Access AccuTnI, and Innotrac Aio! first-generation cTnI assays. We studied serum samples from 15 patients with positive rheumatoid factor but with no indication of myocardial infarction (MI). Additionally, the stability of the sample with different matrices and the influence of hemodialysis on the cTnI concentration were evaluated. Within-assay CVs were 3.2%–10.9%, and between-assay precision ranged from 4.0% to 17.2% for cTnI. The functional sensitivity (CV = 20 %) and the concentration giving CV of 10% were approximated to be 0.02 and 0.04, respectively. The assay was found to be linear within the tested range of 0.063–111.6 μ g/L. The correlations between the second-generation Innotrac Aio!, Access, and AxSYM cTnI assays were good (r coefficients 0.947–0.966), but involved differences in the measured concentrations, and the biases were highest with cTnI at low concentrations. The second-generation Innotrac Aio! cTnI assay was found to be superior to the first-generation assay with regard to precision in the low concentration range. The stability of the cTnI level was best in the serum, lithium-heparin plasma, and lithium-heparin whole blood samples (n = 10 , decrease < 10 % in 24 hours at +20°C and at +4°C. There was no remarkable influence of hemodialysis on the cTnI release. False-positive cTnI values occurred in the presence of very high rheumatoid factor values, that is, over 3000 U/L. The 99th percentile of the apparently healthy reference group was ≤ 0.03   μ g/L. The results demonstrate the very good analytical performance of the second-generation Innotrac Aio! cTnI assay
    corecore