5 research outputs found

    Effect of preheating of low shrinking resin composite on intrapulpal temperature and microtensile bond strength to dent

    Get PDF
    The effect of preheating of the silorane-based resin composite on intrapulpal temperature (IPT) and dentin microtensile bond strength (μTBS) was evaluated. For the IPT, teeth (n = 15) were sectioned to obtain discs of 0.5 mm thickness (2 discs/tooth). The discs were divided into three groups (n = 10/group) according to the temperature of the Filtek LS™ silorane-based resin composite during its placement, either at room temperature (23 ± 1 °C) or preheated to 54 °C or 68 °C using a commercial Calset™ device. Discs were subjected to a simulated intrapulpal pressure (IPP) and placed inside a specially constructed incubator adjusted at 37 °C. IPT was measured before, during and after placement and curing of the resin composite using K-type thermocouple. For μTBS testing, flat occlusal middentin surfaces (n = 24) were obtained. P90 System Adhesive was applied according to manufacturer’s instructions then Filtek LS was placed at the tested temperatures (n = 6). Restorative procedures were done while the specimens were connected to IPP simulation. IPP was maintained and the specimens were immersed in artificial saliva at 37 °C for 24 h before testing. Each specimen was sectioned into sticks (0.9 ± 0.01 mm2). The sticks (24/group) were subjected to μTBS test and their modes of failure were determined using scanning electron microscope (SEM). For both preheated groups, IPT increased equally by 1.5–2 °C upon application of the composite. After light curing, IPT increased by 4–5 °C in all tested groups. Nevertheless, the IPT of the preheated groups required a longer time to return to the baseline temperature. One-way ANOVA revealed no significant difference between the μTBS values of all groups. SEM revealed predominately mixed mode of failure. Preheating of silorane-based resin composite increased the IPT but not to the critical level and had no effect on dentin μTBS

    Endoscopic-Assisted Scleral Fixated IOL in the Management of Secondary Aphakia in Children

    No full text
    Purpose. To evaluate the short-term postoperative outcomes in endoscopic-assisted sclera fixation intraocular lens (IOL) for the management of secondary aphakia in children. Methods. This is a prospective study, whereas 40 aphakic eyes with absence of a good capsular support were implanted by endoscopy-assisted sclera fixation technique. Results. No major intraoperative complications were recorded. All cases were followed up for 6 months. Only transient ocular hypertension occurred in 10 (25%) eyes. Lens decentration and/or tilting were clinically detected in 2 eyes (5%). Ultrasonic biomicroscopic (UBM) examination revealed lens tilting in 2 (5%) of the operated eyes, despite the proper haptics positioning in the ciliary sulcus. Postoperative vitreous hemorrhage was reported in 5 eyes (12.5%) in the early postoperative period and retinal detachment in one eye. A postoperative refractive astigmatism ranging from 0.75 D to 3.75 D (mean 1.7 D ± 0.79) was recorded, as compared to mean preoperative values of 2.00 D, with no statistically significant differences being recorded (p≥0.05). An improvement of BCVA, 1-2 lines on Snellen chart at the end of the follow-up period, was detected in 23 eyes (57.5%) with a mean of 0.6±0.08 SD, as compared to a preoperative mean values of 0.5±0.07 SD (p≥0.05). Conclusion. Using an endoscope for transscleral suturing of intraocular lenses in aphakic pediatric eyes might be considered as being an effective technique that can reduce surgical complications, especially postoperative lens decentration

    Development of multiplex gold nanoparticles biosensors for ultrasensitive detection and genotyping of equine herpes viruses

    No full text
    Abstract Gold nanoparticles (GNPs) biosensors can detect low viral loads and differentiate between viruses types, enabling early diagnosis and effective disease management. In the present study, we developed GNPs biosensors with two different capping agent, citrate-GNPs biosensors and polyvinylpyrrolidone (PVP)-GNPs biosensors for detection of EHV-1 and EHV-4 in multiplex real time PCR (rPCR). Citrate-GNPs and PVP-GNPs biosensors can detect dilution 1010 of EHV-1 with mean Cycle threshold (Ct) 11.7 and 9.6, respectively and one copy as limit of detection, while citrate-GNPs and PVP-GNPs biosensors can detect dilution 1010 of EHV-4 with mean Ct 10.5 and 9.2, respectively and one copy as limit of detection. These findings were confirmed by testing 87 different clinical samples, 4 more samples were positive with multiplex GNPs biosensors rPCR than multiplex rPCR. Multiplex citrate-GNPs and PVP-GNPs biosensors for EHV-1 and EHV-4 are a significant breakthrough in the diagnosis of these virus types. These biosensors offer high sensitivity and specificity, allowing for the accurate detection of the target viruses at very low concentrations and improve the early detection of EHV-1 and EHV-4, leading to faster control of infected animals to prevent the spread of these viruses

    Survival of occlusal ART restorations using high-viscosity glass-ionomer with and without chlorhexidine: A 2-year split-mouth quadruple-blind randomized controlled clinical trial

    Get PDF
    The study question was whether the use of high-viscosity glass-ionomer with chlorhexidine (HVGIC/CHX) for the Atraumatic Restorative Treatment (ART) prepared cavities could achieve a higher restoration survival percentage and be more effective for preventing dentine carious lesions adjacent to the restoration than the use of HVGIC without CHX. The study followed a split-mouth, quadruple-blind, randomized controlled clinical design and lasted 2 years. Patients with at least two small- to medium-sized occlusal cavities were included. The occlusal cavities were prepared according to the ART method and restored with HVGIC/CHX (test) and HVGIC (control). A replica of all restorations available and digital photographs were fabricated at baseline and after 0.5, 1, 1.5 and 2 years and evaluated by two examiners using the ART and Federation Dentaire International (FDI) restoration assessment criteria. Survival curves were constructed using the Kaplan-Meier method, and the log-rank test was used to test for significance between the survival percentages. A total of 100 subjects with an average age of 14.4 years participated. According to the ART restoration assessment criteria, the 2-year survival percentages of ART/HVGIC/CHX (96.8%) and ART/HVGIC (94.8%) did not differ significantly and no significant difference was found between the test (97.9%) and control (96.9%) groups according to the FDI restoration assessment criteria. Eight and five occlusal restorations failed according to the ART and FDI restoration criteria, respectively. No dentine carious lesions along the restoration margin were observed. The 2-year survival of ART restorations in both groups was high. The development of carious dentine lesions adjacent to the restoration was not observed in either treatment group. There is no evidence for modifying HVGIC by incorporating chlorhexidine in order to prevent dentine carious lesion development or to improve the survival of ART restorations in occlusal surfaces in permanent teeth. HVGIC without chlorhexidine can be used successfully to restore occlusal ‘ART-prepared’ cavities in permanent teeth. Keywords: Atraumatic Restorative Treatment (ART), Chlorhexidine, Glass-ionomer cement, High-viscosity glass-ionomer cement, Survival percentage, Clinical tria
    corecore