11 research outputs found

    Mining and analysis of audiology data to find significant factors associated with tinnitus masker

    Get PDF
    Objectives: The objective of this research is to find the factors associated with tinnitus masker from the literature, and by using the large amount of audiology data available from a large NHS (National Health Services, UK) hearing aid clinic. The factors evaluated were hearing impairment, age, gender, hearing aid type, mould and clinical comments. Design: The research includes literature survey for factors associated with tinnitus masker, and performs the analysis of audiology data using statistical and data mining techniques. Setting: This research uses a large audiology data but it also faced the problem of limited data for tinnitus. Participants: It uses 1,316 records for tinnitus and other diagnoses, and 10,437 records of clinical comments from a hearing aid clinic. Primary and secondary outcome measures: The research is looking for variables associated with tinnitus masker, and in future, these variables can be combined into a single model to develop a decision support system to predict about tinnitus masker for a patient. Results: The results demonstrated that tinnitus maskers are more likely to be fit to individuals with milder forms of hearing loss, and the factors age, gender, type of hearing aid and mould were all found significantly associated with tinnitus masker. In particular, those patients having Age<=55 years were more likely to wear a tinnitus masker, as well as those with milder forms of hearing loss. ITE (in the ear) hearing aids were also found associated with tinnitus masker. A feedback on the results of association of mould with tinnitus masker from a professional audiologist of a large NHS (National Health Services, UK) was also taken to better understand them. The results were obtained with different accuracy for different techniques. For example, the chi-squared test results were obtained with 95% accuracy, for Support and Confidence only those results were retained which had more than 1% Support and 80% Confidence. Conclusions: The variables audiograms, age, gender, hearing aid type and mould were found associated with the choice of tinnitus masker in the literature and by using statistical and data mining techniques. The further work in this research would lead to the development of a decision support system for tinnitus masker with an explanation that how that decision was obtained

    Long-term reductions in tinnitus severity

    Get PDF
    BACKGROUND: This study was undertaken to assess long-term changes in tinnitus severity exhibited by patients who completed a comprehensive tinnitus management program; to identify factors that contributed to changes in tinnitus severity within this population; to contribute to the development and refinement of effective assessment and management procedures for tinnitus. METHODS: Detailed questionnaires were mailed to 300 consecutive patients prior to their initial appointment at the Oregon Health & Science University Tinnitus Clinic. All patients were then evaluated and treated within a comprehensive tinnitus management program. Follow-up questionnaires were mailed to the same 300 patients 6 to 36 months after their initial tinnitus clinic appointment. RESULTS: One hundred ninety patients (133 males, 57 females; mean age 57 years) returned follow-up questionnaires 6 to 36 months (mean = 22 months) after their initial tinnitus clinic appointment. This group of patients exhibited significant long-term reductions in self-rated tinnitus loudness, Tinnitus Severity Index scores, tinnitus-related anxiety and prevalence of current depression. Patients who improved their sleep patterns or Beck Depression Inventory scores exhibited greater reductions of tinnitus severity scores than patients who continued to experience insomnia and depression at follow-up. CONCLUSIONS: Individualized tinnitus management programs that were designed for each patient contributed to overall reductions in tinnitus severity exhibited on follow-up questionnaires. Identification and treatment of patients experiencing anxiety, insomnia or depression are vital components of an effective tinnitus management program. Utilization of acoustic therapy also contributed to improvements exhibited by these patients

    Tinnitus before and 6 Months after Cochlear Implantation

    Full text link
    In this prospective multicenter study, tinnitus loudness and tinnitus-related distress were investigated in 174 cochlear implant (CI) candidates who underwent CI surgery at a Swiss cochlear implant center. All subjects participated in two session, one preoperatively and one 6 months after device activation. In both sessions, tinnitus loudness was assessed using a visual analogue scale and tinnitus distress using a standardized tinnitus questionnaire. The data were compared with unaided pre- and postoperative pure tone thresholds, and postoperative speech reception scores. 71.8% of the subjects reported tinnitus preoperatively. Six months after CI surgery 20.0% of these reported abolition of their tinnitus, 51.2% a subjective improvement, 21.6% no change and 7.2% a deterioration. Of the 49 (28.2%) subjects with no tinnitus preoperatively, 5 developed tinnitus 6 months after CI. These 5 had poorer speech understanding after CI surgery with their device than the group who remained tinnitus free. We found no correlation between tinnitus improvement, age, duration of tinnitus, or change in unaided hearing thresholds between the two sessions
    corecore