524 research outputs found

    Electronic Structure of the YH3 Phase from Angle-Resolved Photoemission Spectroscopy

    Full text link
    Yttrium can be loaded with hydrogen up to high concentrations causing dramatic structural and electronic changes of the host lattice. We report on angle-resolved photoemission experiments of the Y trihydride phase. Most importantly, we find the absence of metal d-bands at the Fermi level and a set of flat, H-induced bands located at much higher binding energy than predicted, indicating an increased electron affinity at H sites

    Rupture and Migration of an Endovascular Stent in the Brachiocephalic Trunk Causing a Vertebral Steal Syndrome

    Get PDF
    Delayed stent fracture has been observed in many different arteries and may represent a risk factor for restenosis. We describe the case of a delayed rupture of an endovascular brachiocephalic trunk stent. The complete fracture allowed a fragment to migrate distally and tilt, resulting in a hemodynamic pattern similar to that of a prevertebral stenosis with complete inversion of the homolateral vertebral blood flow. The induced vertebral steal syndrome as well as the risk of cerebral embolism was corrected by an aortobrachiocephalic bypass and resection of the ruptured sten

    Gelsolin superfamily proteins: key regulators of cellular functions

    Get PDF
    Abstract.: Cytoskeletal rearrangement occurs in a variety of cellular processes and involves a wide spectrum of proteins. Among these, the gelsolin superfamily proteins control actin organization by severing filaments, capping filament ends and nucleating actin assembly [1]. Gelsolin is the founding member of this family, which now contains at least another six members: villin, adseverin, capG, advillin, supervillin and flightless I. In addition to their respective role in actin filament remodeling, these proteins have some specific and apparently non-overlapping particular roles in several cellular processes, including cell motility, control of apoptosis and regulation of phagocytosis (summarized in table 1). Evidence suggests that proteins belonging to the gelsolin superfamily may be involved in other processes, including gene expression regulation. This review will focus on some of the known functions of the gelsolin superfamily proteins, thus providing a basis for reflection on other possible and as yet incompletely understood roles for these protein

    Atrial assist device, a new alternative to lifelong anticoagulation?

    Get PDF
    OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure

    Elastic behaviour of the carotid artery in intact spontaneously hypertensive rats

    Get PDF
    Intact spontaneously hypertensive rats (SHR) were studied to assess the effect of prolonged antihypertensive treatment on the elastic behaviour of the external carotid artery. Thirty-week-old SHR received the ACE inhibitor captopril, the ateriolar dilator hydralazine or their vehicle for 6 weeks. These rats were compared to normotensive, vehicle treated WKY rats. The internal diameter of the carotid artery was measured continuously in halothane-anaesthetized rats using an echo-tracking device, and intra-arterial pressure was also monitored continuously, on the controlateral side. Captopril- and hydralazinetreated SHR as well as normotensive controls had similar blood pressure values. No significant shift in the distensibility-pressure curves was observed among vehicle-treated SHR and WKY rats or the SHR which had received captopril or hydralazine. Histological examination of the carotid artery fixed ex vivo with paraformaldehyde showed a significant increase in cross-sectional area in vehicle-treated SHR as compared to their normotensive counterparts. These results therefore suggest that the elastic behaviour of elastic arteries is not necessarily altered by the structural changes developing in response to hypertensio

    Animal model to compare the effects of suture technique on cross-sectional compliance on end-to-side anastomoses

    Get PDF
    Objective: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. Methods: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = π × mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC = δCSAA/δP where δP is the mean pulse pressure and δCSAA is the mean CSAA during cardiac cycle. Results: We collected a total of 1 200 000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94±0.4 mm2 and a mean CSAA in diastole of 26.30±0.5 mm2 (mean δCSAA was 0.64 mm2). CSAC for running suture was 4.5×10−6m2/kPa. For interrupted suture we had a mean CSAA in systole of 21.98±0.2 mm2 and a mean CSAA in diastole of 17.38±0.3 mm2 (mean δCSAA was 4.6±0.1 mm2). CSAC for interrupted suture was 11×10−6 m2/kPa. Conclusions: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo™ anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomose

    Use of biomarkers or echocardiography in pulmonary embolism: the Swiss Venous Thromboembolism Registry

    Get PDF
    Background: Cardiac biomarkers and echocardiography for assessing right ventricular function are recommended to risk stratify patients with acute non-massive pulmonary embolism (PE), but it remains unclear if these tests are performed systematically in daily practice. Design and methods: Overall, 587 patients with acute non-massive PE from 18 hospitals were enrolled in the Swiss Venous Thromboembolism Registry (SWIVTER): 178 (30%) neither had a biomarker test nor an echocardiographic evaluation, 196 (34%) had a biomarker test only, 47 (8%) had an echocardiogram only and 166 (28%) had both tests. Results: Among the 409 (70%) patients with biomarkers or echocardiography, 210 (51%) had at least one positive test and 67 (16%) had positive biomarkers and right ventricular dysfunction. The ICU admission rates were 5.1% without vs. 5.6% with testing (P = 0.78), and thrombolysis or embolectomy were performed in 2.8% vs. 4.9%, respectively (P = 0.25). In multivariate analysis, syncope [odds ratio (OR): 3.49, 95% confidence interval (CI): 1.20-10.15; P = 0.022], tachycardia (OR: 2.31, 95% CI: 1.37-3.91; P = 0.002) and increasing age (OR: 1.02; 95% CI: 1.01-1.04; P < 0.001) were associated with testing of cardiac risk; outpatient status at the time of PE diagnosis (OR: 2.24, 95% CI: 1.49-3.36; P < 0.001), cancer (OR: 1.81, 95% CI: 1.17-2.79; P = 0.008) and provoked PE (OR: 1.58, 95% CI: 1.05-2.40; P = 0.029) were associated with its absence. Conclusions: Although elderly patients and those with clinically severe PE were more likely to receive a biomarker test or an echocardiogram, these tools were used in only two-thirds of the patients with acute non-massive PE and rarely in combinatio
    corecore