10,214 research outputs found
Sonic impedance technique detects flaws in polyurethane foam spray-on insulation
Sonic impedance testing detects voids and unbonded regions as small as 1 inch in diameter by 0.03 inch thick. Measurements are made manually or by automatic scanning and the readout is made by meter or recorder
Ultrasonic scanning system for in-place inspection of brazed-tube joints
System detects defects of .051 cm in diameter and larger. System incorporates scanning head assembly including boot enclosed transducer, slip ring assembly, drive mechanism, and servotransmitter. Ultrasonic flaw detector, prototype recorder, and special recorder complete system
Ultrasonic scanning system for in-place inspection of brazed tube joints
A miniaturized ultrasonic scanning system for nondestructive in-place, non-immersion testing of brazed joints in stainless-steel tubing is described. The system is capable of scanning brazed tube joints, with limited clearance access, in 1/4 through 5/8 inch union, tee, elbow and cross configurations. The system has the capability to detect defective conditions now associated with material density changes in addition to those which are depended upon density variations. The system includes a miniaturized scanning head assembly that fits around a tube joint and rotates the transducer around and down the joint in a continuous spiral motion. The C-scan recorder is similar in principle to conventional models except that it was specially designed to track the continuous spiral scan of the tube joint. The scanner and recorder can be operated with most commercially available ultrasonic flaw detectors
Anion receptor chemistry: highlights from 2011 and 2012
This review covers advances in anion complexation in the years 2011 and 2012. The review covers both organic and inorganic systems and also highlights the applications to which anion receptors can be applied such as self-assembly and molecular architecture, sensing, catalysis and anion transport
Highly effective yet simple transmembrane anion transporters based upon ortho-phenylenediamine bis-ureas
Simple, highly fluorinated receptors are shown to function as highly effective transmembrane anion antiporters with the most active transporters rivalling the transport efficacy of natural anion transporter prodigiosin for bicarbonate
Magnetic fields of our Galaxy on large and small scales
Magnetic fields have been observed on all scales in our Galaxy, from AU to
kpc. With pulsar dispersion measures and rotation measures, we can directly
measure the magnetic fields in a very large region of the Galactic disk. The
results show that the large-scale magnetic fields are aligned with the spiral
arms but reverse their directions many times from the inner-most arm (Norma) to
the outer arm (Perseus). The Zeeman splitting measurements of masers in HII
regions or star-formation regions not only show the structured fields inside
clouds, but also have a clear pattern in the global Galactic distribution of
all measured clouds which indicates the possible connection of the large-scale
and small-scale magnetic fields.Comment: 9 pages. Invited Talk at IAU Symp.242, 'Astrophysical Masers and
their Environments', Proceedings edited by J. M. Chapman & W. A. Baa
Sizes of Voids as a test for Dark Matter Models
We use the void probability statistics to study the redshift-space galaxy
distribution as described by a volume-limited subsample of the Perseus-Pisces
survey. We compare the results with the same analysis realized on artificial
samples, extracted from high-resolution N-body simulations by reproducing the
observational biases of the real data set. Simulations are run for the
Cold+HotDM model (CHDM) and for unbiased and biased (b=1.5) CDM models in a 50
Mpc/h box. We identify galaxies as residing in peaks of the evolved density
field. We fragment overmerged structures into individual galaxies so as to
reproduce both the correct luminosity function (after assuming M/ L values for
the resulting galaxy groups) and the two-point correlation function. Our main
result is that a void-probability function (VPF) from the standard CHDM model
with fractions 60% cold, 30% hot, 10% barions, exceeds the observational VPF
with a high confidence level. CDM models produce smaller VPF independent of the
biasing parameter. We verify the robustness of this result against changing the
observer position in the simulations and the galaxy identification in the
evolved density field.Comment: 15 pages, postscrip
- …