20 research outputs found

    Voluntary versus ABC breath-hold in the context of VMAT for breast and locoregional lymph node radiotherapy including the internal mammary chain

    Get PDF
    Background: Deep-inspiration breath-hold (DIBH) reduces radiation dose to the heart in patients undergoing locoregional breast radiotherapy. In the context of tangential irradiation of the breast/ chest wall, a voluntary breath hold (vDIBH) technique has been shown to be as reproducible as a machine-assisted breath hold technique using the active breathing co-ordinator (ABCTM, Elekta, Crawley, UK, ABC_DIBH). This study compares set-up reproducibility for vDIBH versus ABC_DIBH in patients undergoing volumetric-modulated arc radiotherapy (VMAT) for breast cancer, both with and without wax bolus. Method: Patients with breast cancer requiring pan regional lymph node VMAT +/� wax bolus in breathhold were CT scanned in vDIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1–7 and the other for fractions 8–15. Daily cone beam computed tomography (CBCT) was performed and registered to planning-CT using bony anatomy. Within-patient comparisons of mean daily chest wall position were made using a paired t-test. Population, systematic (P) and random errors (a) were estimated. Intrafraction reproducibility was assessed by comparing chest wall position and diaphragm movement between consecutive breath holds on CBCT. Results: 16 patients were recruited. All completed treatment with both techniques (9 patients with wax bolus, 7 patients without). CBCT derived P were 2.1–6.4 mm (ABC_DIBH) and 2.1–4.9 mm (vDIBH), a were 1.7–2.6 mm (ABC_DIBH) and 2.2–2.7 mm (vDIBH) and mean daily chest wall displacements (MD) were 0.0–1.5 mm (ABC_DIBH) and - 0.1–1.6 vDIBH (all p non-significant). Chest wall and diaphragm position was equivalent between consecutive breath holds in ABC and vDIBH (median difference 1.0 mm and 0.8 mm respectively, non p significant) demonstrating equivalent intrafraction reproducibility. Conclusion: This study demonstrates that a simple voluntary breath hold technique is feasible in combination with VMAT (+/� bolus) and is as reproducible as ABC_DIBH with VMAT for the irradiation of the breast and axillary and IMC lymph nodes in breast cancer patients

    Pharmacokinetics and Pharmacodynamics of Once-Daily versus Twice-Daily Raltegravir in Treatment-Naïve HIV-Infected Patients

    Get PDF
    ABSTRACT QDMRK was a phase III clinical trial of raltegravir given once daily (QD) (800-mg dose) versus twice daily (BID) (400 mg per dose), each in combination with once-daily coformulated tenofovir-emtricitabine, in treatment-naive HIV-infected patients. Pharmacokinetic (PK) and pharmacokinetic/pharmacodynamic (PK/PD) analyses were conducted using a 2-step approach: individual non-model-based PK parameters from observed sparse concentration data were determined, followed by statistical analysis of potential relationships between PK and efficacy response parameters after 48 weeks of treatment. Sparse PK sampling was performed for all patients (QD, n = 380; BID, n = 384); selected sites performed an intensive PK evaluation at week 4 (QD, n = 22; BID, n = 20). In the intensive PK subgroup, daily exposures (area under the concentration-time curve from 0 to 24 h [AUC 0–24 ]) were similar between the two regimens, but patients on 800 mg QD experienced ∼4-fold-higher maximum drug concentration in plasma ( C max ) values and ∼6-fold-lower trough drug concentration ( C trough ) values than those on 400 mg BID. Geometric mean (GM) C trough values were similarly lower in the sparse PK analysis. With BID dosing, there was no indication of any significant PK/PD association over the range of tested PK parameters. With QD dosing, C trough values correlated with the likelihood of virologic response. Failure to achieve an HIV RNA level of <50 copies/ml appeared predominantly at high baseline HIV RNA levels in both treatment arms and was associated with lower values of GM C trough in the 800-mg-QD arm, though other possible drivers of efficacy, such as time above a threshold concentration, could not be evaluated due to the sparse sampling scheme. Together, these findings emphasize the importance of the shape of the plasma concentration-versus-time curve for long-term efficacy

    Voluntary versus ABC breath-hold in the context of VMAT for breast and locoregional lymph node radiotherapy including the internal mammary chain.

    Get PDF
    Background Deep-inspiration breath-hold (DIBH) reduces radiation dose to the heart in patients undergoing locoregional breast radiotherapy. In the context of tangential irradiation of the breast/ chest wall, a voluntary breath hold (vDIBH) technique has been shown to be as reproducible as a machine-assisted breath hold technique using the active breathing co-ordinator (ABC™, Elekta, Crawley, UK, ABC_DIBH). This study compares set-up reproducibility for vDIBH versus ABC_DIBH in patients undergoing volumetric-modulated arc radiotherapy (VMAT) for breast cancer, both with and without wax bolus.Method Patients with breast cancer requiring pan regional lymph node VMAT +/- wax bolus in breath-hold were CT scanned in vDIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1-7 and the other for fractions 8-15. Daily cone beam computed tomography (CBCT) was performed and registered to planning-CT using bony anatomy. Within-patient comparisons of mean daily chest wall position were made using a paired t -test. Population, systematic (∑) and random errors (α) were estimated. Intrafraction reproducibility was assessed by comparing chest wall position and diaphragm movement between consecutive breath holds on CBCT.Results 16 patients were recruited. All completed treatment with both techniques (9 patients with wax bolus, 7 patients without). CBCT derived ∑ were 2.1-6.4 mm (ABC_DIBH) and 2.1-4.9 mm (vDIBH), α were 1.7-2.6 mm (ABC_DIBH) and 2.2-2.7 mm (vDIBH) and mean daily chest wall displacements (MD) were 0.0-1.5 mm (ABC_DIBH) and - 0.1-1.6 vDIBH (all p non-significant). Chest wall and diaphragm position was equivalent between consecutive breath holds in ABC and vDIBH (median difference 1.0 mm and 0.8 mm respectively, non p significant) demonstrating equivalent intrafraction reproducibility.Conclusion This study demonstrates that a simple voluntary breath hold technique is feasible in combination with VMAT (+/- bolus) and is as reproducible as ABC_DIBH with VMAT for the irradiation of the breast and axillary and IMC lymph nodes in breast cancer patients
    corecore