518 research outputs found

    Quantitative ultrasonic assessment for detecting microscopic cartilage damage in osteoarthritis

    Get PDF
    Osteoarthritis (OA) is one of the most prevalent chronic conditions. The histological cartilage changes in OA include surface erosion and irregularities, deep fissures, and alterations in the staining of the matrix. The reversibility of these chondral alterations is still under debate. It is expected that clinical and basic science studies will provide the clinician with new scientific information about the natural history and optimal treatment of OA at an early stage. However, a reliable method for detecting microscopic changes in early OA has not yet been established. We have developed a novel system for evaluating articular cartilage, in which the acoustic properties of the articular cartilage are measured by introducing an ultrasonic probe into the knee joint under arthroscopy. The purpose of this study was to assess microscopic cartilage damage in OA by using this cartilage evaluation system on collagenase-treated articular cartilage in vivo and in vitro. Ultrasonic echoes from articular cartilage were converted into a wavelet map by wavelet transformation. On the wavelet map, the maximum magnitude and echo duration were selected as quantitative indices. Using these indices, the articular cartilage was examined to elucidate the relationships of the ultrasonic analysis with biochemical, biomechanical and histological analyses. In the in vitro study, the maximum magnitude decreased as the duration of collagenase digestion increased. Correlations were observed between the maximum magnitude and the proteoglycan content from biochemical findings, and the maximum magnitude and the aggregate modulus from biomechanical findings. From the histological findings, matrix staining of the surface layer to a depth of 500 μm was closely related to the maximum magnitude. In the in vivo study, the maximum magnitude decreased with increasing duration of the collagenase injection. There was a significant correlation between the maximum magnitude and the aggregate modulus. The evaluation system therefore successfully detected microscopic changes in degenerated cartilage with the use of collagen-induced OA

    Photosynthetic physiology and primary productivity of phytoplankton in the Australian sector of the Southern Ocean

    Get PDF
    第2回極域科学シンポジウム 共通セッション「海氷圏の生物地球化学」 11月16日(水) 統計数理研究所 3階セミナー

    Spectrocolorimetric evaluation of repaired articular cartilage after a microfracture

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In clinical practice, surgeons differentiate color changes in repaired cartilage compared with surrounding intact cartilage, but cannot quantify these color changes. Objective assessments are required. A spectrocolorimeter was used to evaluate whether intact and repaired cartilage can be quantified.</p> <p>Findings</p> <p>We investigated the use of a spectrocolorimeter and the application of two color models (L* a* b* colorimetric system and spectral reflectance distribution) to describe and quantify articular cartilage. In this study, we measured the colors of intact and repaired cartilage after a microfracture. Histologically, the repaired cartilage was a mixture of fibrocartilage and hyaline cartilage. In the L* a* b* colorimetric system, the L* and a* values recovered to close to the values of intact cartilage, whereas the b* value decreased over time after the operation. Regarding the spectral reflectance distribution at 12 weeks after the operation, the repaired cartilage had a higher spectral reflectance ratio than intact cartilage between wavelengths of 400 to 470 nm.</p> <p>Conclusion</p> <p>This study reports the first results regarding the relationship between spectrocolorimetric evaluation and the histological findings of repair cartilage after a microfracture. Our findings demonstrate the ability of spectrocolorimetric measurement to judge the repair cartilage after treatment on the basis of objective data such as the L*, a* and b* values and the SRP as a coincidence index of the spectral reflectance curve.</p

    Lachmanテスト時に発生する膝関節音 : 健常膝と前十字靭帯損傷膝での比較検討

    Get PDF
    BACKGROUND: The Lachman test is clinically considered to be a reliable physical examination for anterior cruciate ligament (ACL) deficiency. However, the test involves subjective judgement of differences in tibial translation and endpoint quality. An auscultation system has been developed to allow assessment of the Lachman test. The knee joint sound during the Lachman test was analyzed using fast Fourier transformation. The purpose of the present study was to quantitatively evaluate knee joint sounds in healthy and ACL-deficient human knees. METHODS: Sixty healthy volunteers and 24 patients with ACL injury were examined. The Lachman test with joint auscultation was evaluated using a microphone. Knee joint sound during the Lachman test (Lachman sound) was analyzed by fast Fourier transformation. As quantitative indices of the Lachman sound, the peak sound (Lachman peak sound) as the maximum relative amplitude (acoustic pressure) and its frequency were used. RESULTS: In healthy volunteers, the mean Lachman peak sound of intact knees was 100.6 Hz in frequency and -45 dB in acoustic pressure. Moreover, a sex difference was found in the frequency of the Lachman peak sound. In patients with ACL injury, the frequency of the Lachman peak sound of the ACL-deficient knees was widely dispersed. In the ACL-deficient knees, the mean Lachman peak sound was 306.8 Hz in frequency and -63.1 dB in acoustic pressure. If the reference range was set at the frequency of the healthy volunteer Lachman peak sound, the sensitivity, specificity, positive predictive value, and negative predictive value were 83.3%, 95.6%, 95.2%, and 85.2%, respectively. CONCLUSION: Knee joint auscultation during the Lachman test was capable of judging ACL deficiency on the basis of objective data. In particular, the frequency of the Lachman peak sound was able to assess ACL condition.博士(医学)・甲第673号・平成29年6月28日Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved

    Spectrocolorimetric assessment of cartilage plugs after autologous osteochondral grafting: correlations between color indices and histological findings in a rabbit model

    Get PDF
    We investigated the use of a commercial spectrocolorimeter and the application of two color models (L* a* b* colorimetric system and spectral reflectance distribution) to describe and quantify cartilage plugs in a rabbit model of osteochondral autografting. Osteochondral plugs were removed and then replaced in their original positions in Japanese white rabbits. The rabbits were sacrificed at 4 or 12 weeks after the operation and cartilage samples were assessed using a spectrocolorimeter. The samples were retrospectively divided into two groups on the basis of the histological findings (group H: hyaline cartilage, successful; group F: fibrous tissue or fibrocartilage, failure) and investigated for possible significant differences in the spectrocolorimetric analyses between the two groups. Moreover, the relationships between the spectrocolorimetric indices and the Mankin histological score were examined. In the L* a* b* colorimetric system, the L* values were significantly lower in group H than in group F (P = 0.02), whereas the a* values were significantly higher in group H than in group F (P = 0.006). Regarding the spectral reflectance distribution, the spectral reflectance percentage 470 (SRP470) values, as a coincidence index for the spectral reflectance distribution (400 to 470 nm in wavelength) of the cartilage plugs with respect to intact cartilage, were 99.8 ± 6.7% in group H and 119.8 ± 10.6% in group F, and the difference between these values was significant (P = 0.005). Furthermore, the a* values were significantly correlated with the histological score (P = 0.004, r = -0.76). The SRP470 values were also significantly correlated with the histological score (P = 0.01, r = 0.67). Our findings demonstrate the ability of spectrocolorimetric measurements to predict the histological findings of cartilage plugs after autologous osteochondral grafting. In particular, the a* values and SRP470 values can be used to judge the surface condition of an osteochondral plug on the basis of objective data. Therefore, spectrocolorimetry may contribute to orthopedics, rheumatology and related research in arthritis, and arthroscopic use of this method may potentially be preferable for in vivo assessment
    corecore