37 research outputs found

    Viterbi decoding of CRES signals in Project 8

    Get PDF
    Cyclotron radiation emission spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informational limits on the optimal detection of cyclotron radiation signals in this class of gas-filled CRES experiments, thereby providing concrete limits from which future reconstruction algorithms, as well as detector designs, can be constrained. The validity of the resultant decision rules is confirmed using both Monte Carlo and Project 8 data

    SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

    Get PDF
    Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle\u27s motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. We find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals

    Tritium Beta Spectrum and Neutrino Mass Limit from Cyclotron Radiation Emission Spectroscopy

    Get PDF
    The absolute scale of the neutrino mass plays a critical role in physics at every scale, from the particle to cosmological. Measurements of the tritium endpoint spectrum have provided the most precise direct limit on the neutrino mass scale. In this Letter, we present advances by Project 8 to the Cyclotron Radiation Emission Spectroscopy (CRES) technique culminating in the first frequency-based neutrino mass limit. With only a cm3^3-scale physical detection volume, a limit of mβm_\beta<180 eV is extracted from the background-free measurement of the continuous tritium beta spectrum. Using 83m^{83{\rm m}}Kr calibration data, an improved resolution of 1.66±\pm0.16 eV (FWHM) is measured, the detector response model is validated, and the efficiency is characterized over the multi-keV tritium analysis window. These measurements establish the potential of CRES for a high-sensitivity next-generation direct neutrino mass experiment featuring low background and high resolution.Comment: 7 pages, 5 figures, for submission to PR

    Isolated Cataplexy: A Familial Study

    No full text
    Four members of a family, a mother, her two sons, and the mother\u27s second cousin, presented with a history of isolated cataplexy without excessive daytime sleepiness or other symptoms typical of narcolepsy. They were polygraphically monitored during one night followed by a day of multiple nap tests. No subject manifested objective daytime sleepiness as measured by short latencies to sleep onset during daytime naps, and no subject exhibited periods of sleep onset rapid eye movement sleep in either the night or nap recordings. The incidence of isolated cataplexy in this family was traced by history through six generations. We conclude that isolated cataplexy in this family is a genetically transmitted dominant trait with incomplete penetrance which occurs independently of daytime sleepiness and the full-blown narcolepsy syndrome

    Advancement of Sensor Integrated Organ-on-Chip Devices

    Get PDF
    Organ-on-chip devices have provided the pharmaceutical and tissue engineering worlds much hope since they arrived and began to grow in sophistication. However, limitations for their applicability were soon realized as they lacked real-time monitoring and sensing capabilities. The users of these devices relied solely on endpoint analysis for the results of their tests, which created a chasm in the understanding of life between the lab the natural world. However, this gap is being bridged with sensors that are integrated into organ-on-chip devices. This review goes in-depth on different sensing methods, giving examples for various research on mechanical, electrical resistance, and bead-based sensors, and the prospects of each. Furthermore, the review covers works conducted that use specific sensors for oxygen, and various metabolites to characterize cellular behavior and response in real-time. Together, the outline of these works gives a thorough analysis of the design methodology and sophistication of the current sensor integrated organ-on-chips.This article is published as Clarke, Gabriel A., Brenna X. Hartse, Amir Ehsan Niaraki Asli, Mehrnoosh Taghavimehr, Niloofar Hashemi, Mehran Abbasi Shirsavar, Reza Montazami et al. "Advancement of sensor integrated organ-on-chip devices." Sensors 21, no. 4 (2021): 1367. DOI: 10.3390/s21041367. Copyright 2021 by the authors. Attribution 4.0 International (CC BY 4.0). Posted with permission

    Advancement of Sensor Integrated Organ-on-Chip Devices

    No full text
    Organ-on-chip devices have provided the pharmaceutical and tissue engineering worlds much hope since they arrived and began to grow in sophistication. However, limitations for their applicability were soon realized as they lacked real-time monitoring and sensing capabilities. The users of these devices relied solely on endpoint analysis for the results of their tests, which created a chasm in the understanding of life between the lab the natural world. However, this gap is being bridged with sensors that are integrated into organ-on-chip devices. This review goes in-depth on different sensing methods, giving examples for various research on mechanical, electrical resistance, and bead-based sensors, and the prospects of each. Furthermore, the review covers works conducted that use specific sensors for oxygen, and various metabolites to characterize cellular behavior and response in real-time. Together, the outline of these works gives a thorough analysis of the design methodology and sophistication of the current sensor integrated organ-on-chips
    corecore