32 research outputs found

    The function of histone methylation and acetylation regulators in GBM pathophysiology

    Get PDF
    Glioblastoma (GBM) is the most common and lethal primary brain malignancy and is characterized by a high degree of intra and intertumor cellular heterogeneity, a starkly immunosuppressive tumor microenvironment, and nearly universal recurrence. The application of various genomic approaches has allowed us to understand the core molecular signatures, transcriptional states, and DNA methylation patterns that define GBM. Histone posttranslational modifications (PTMs) have been shown to influence oncogenesis in a variety of malignancies, including other forms of glioma, yet comparatively less effort has been placed on understanding the transcriptional impact and regulation of histone PTMs in the context of GBM. In this review we discuss work that investigates the role of histone acetylating and methylating enzymes in GBM pathogenesis, as well as the effects of targeted inhibition of these enzymes. We then synthesize broader genomic and epigenomic approaches to understand the influence of histone PTMs on chromatin architecture and transcription within GBM and finally, explore the limitations of current research in this field before proposing future directions for this area of research

    Repeated measures of mammographic density and texture to evaluate prediction and risk of breast cancer: A systematic review of the methods used in the literature

    Get PDF
    PURPOSE: It may be important for women to have mammograms at different points in time to track changes in breast density, as fluctuations in breast density can affect breast cancer risk. This systematic review aimed to assess methods used to relate repeated mammographic images to breast cancer risk. METHODS: The databases including Medline (Ovid) 1946-, Embase.com 1947-, CINAHL Plus 1937-, Scopus 1823-, Cochrane Library (including CENTRAL), and Clinicaltrials.gov were searched through October 2021. Eligibility criteria included published articles in English describing the relationship of change in mammographic features with risk of breast cancer. Risk of bias was assessed using the Quality in Prognostic Studies tool. RESULTS: Twenty articles were included. The Breast Imaging Reporting and Data System and Cumulus were most commonly used for classifying mammographic density and automated assessment was used on more recent digital mammograms. Time between mammograms varied from 1 year to a median of 4.1, and only nine of the studies used more than two mammograms. Several studies showed that adding change of density or mammographic features improved model performance. Variation in risk of bias of studies was highest in prognostic factor measurement and study confounding. CONCLUSION: This review provided an updated overview and revealed research gaps in assessment of the use of texture features, risk prediction, and AUC. We provide recommendations for future studies using repeated measure methods for mammogram images to improve risk classification and risk prediction for women to tailor screening and prevention strategies to level of risk

    Effectiveness and minimum effective dose of app-based mobile health interventions for anxiety and depression symptom reduction: Systematic review and meta-analysis

    Get PDF
    BACKGROUND: Mobile health (mHealth) apps offer new opportunities to deliver psychological treatments for mental illness in an accessible, private format. The results of several previous systematic reviews support the use of app-based mHealth interventions for anxiety and depression symptom management. However, it remains unclear how much or how long the minimum treatment dose is for an mHealth intervention to be effective. Just-in-time adaptive intervention (JITAI) has been introduced in the mHealth domain to facilitate behavior changes and is positioned to guide the design of mHealth interventions with enhanced adherence and effectiveness. OBJECTIVE: Inspired by the JITAI framework, we conducted a systematic review and meta-analysis to evaluate the dose effectiveness of app-based mHealth interventions for anxiety and depression symptom reduction. METHODS: We conducted a literature search on 7 databases (ie, Ovid MEDLINE, Embase, PsycInfo, Scopus, Cochrane Library (eg, CENTRAL), ScienceDirect, and ClinicalTrials, for publications from January 2012 to April 2020. We included randomized controlled trials (RCTs) evaluating app-based mHealth interventions for anxiety and depression. The study selection and data extraction process followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We estimated the pooled effect size using Hedge g and appraised study quality using the revised Cochrane risk-of-bias tool for RCTs. RESULTS: We included 15 studies involving 2627 participants for 18 app-based mHealth interventions. Participants in the intervention groups showed a significant effect on anxiety (Hedge g=-.10, 95% CI -0.14 to -0.06, I2=0%) but not on depression (Hedge g=-.08, 95% CI -0.23 to 0.07, I2=4%). Interventions of at least 7 weeks\u27 duration had larger effect sizes on anxiety symptom reduction. CONCLUSIONS: There is inconclusive evidence for clinical use of app-based mHealth interventions for anxiety and depression at the current stage due to the small to nonsignificant effects of the interventions and study quality concerns. The recommended dose of mHealth interventions and the sustainability of intervention effectiveness remain unclear and require further investigation

    Objective response to immune checkpoint inhibitor therapy in NRAS-mutant melanoma: A systematic review and meta-analysis

    Get PDF
    INTRODUCTION: METHODS: We performed a comprehensive literature search across several large databases. Inclusion criteria were trials, cohorts, and large case series that analyzed the primary outcome of objective response rate by RESULTS: Data on 1770 patients from ten articles were pooled for meta-analysis, and the objective response rate to ICIs was calculated to compare DISCUSSION: In this meta-analysis evaluating the impact o

    Death and myocardial infarction following initial revascularization versus optimal medical therapy in chronic coronary syndromes with myocardial ischemia: A systematic review and meta-analysis of contemporary randomized controlled trials

    Get PDF
    Background In chronic coronary syndromes, myocardial ischemia is associated with a greater risk of death and nonfatal myocardial infarction (MI). We sought to compare the effect of initial revascularization with percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) plus optimal medical therapy (OMT) with OMT alone in patients with chronic coronary syndrome and myocardial ischemia on long-term death and nonfatal MI. Methods and Results Ovid Medline, Embase, Scopus, and Cochrane Library databases were searched for randomized controlled trials of PCI or CABG plus OMT versus OMT alone for patients with chronic coronary syndromes. Studies were screened and data were extracted independently by 2 authors. Random-effects models were used to generate pooled treatment effects. The search yielded 7 randomized controlled trials that randomized 10 797 patients. Median follow-up was 5 years. Death occurred in 640 of the 5413 patients (11.8%) randomized to revascularization and in 647 of the 5384 patients (12%) randomized to OMT (odds ratio [OR], 0.97; 95% CI, 0.86-1.09

    Reference Ranges of Left Ventricular Strain Measures by Two-Dimensional Speckle-Tracking Echocardiography in Children: A Systematic Review and Meta-Analysis

    Get PDF
    BACKGROUND: Establishment of the range of reference values and associated variations of two-dimensional speckle-tracking echocardiography (2DSTE)-derived left ventricular (LV) strain is a prerequisite for its routine clinical adoption in pediatrics. The aims of this study were to perform a meta-analysis of normal ranges of LV global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) measurements derived by 2DSTE in children and to identify confounding factors that may contribute to variance in reported measures. METHODS: A systematic review was launched in MEDLINE, Embase, Scopus, the Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library. Search hedges were created to cover the concepts of pediatrics, STE, and left-heart ventricle. Two investigators independently identified and included studies if they reported 2DSTE-derived LV GLS, GCS, or GRS. The weighted mean was estimated by using random effects models with 95% CIs, heterogeneity was assessed using the Cochran Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using the Egger test. Effects of demographic (age), clinical, and vendor variables were assessed in a metaregression. RESULTS: The search identified 2,325 children from 43 data sets. The reported normal mean values of GLS among the studies varied from -16.7% to -23.6% (mean, -20.2%; 95% CI, -19.5% to -20.8%), GCS varied from -12.9% to -31.4% (mean, -22.3%; 95% CI, -19.9% to -24.6%), and GRS varied from 33.9% to 54.5% (mean, 45.2%; 95% CI, 38.3% to 51.7%). Twenty-six studies reported longitudinal strain only from the apical four-chamber view, with a mean of -20.4% (95% CI, -19.8% to -21.7%). Twenty-three studies reported circumferential strain (mean, -20.3%; 95% CI, -19.4% to -21.2%) and radial strain (mean, 46.7%; 95% CI, 42.3% to 51.1%) from the short-axis view at the midventricular level. A significant apex-to-base segmental longitudinal strain gradient (P 94% and P < .001 for each strain measure), which was not explained by age, gender, body surface area, blood pressure, heart rate, frame rate, frame rate/heart rate ratio, tissue-tracking methodology, location of reported strain value along the strain curve, ultrasound equipment, or software. The metaregression showed that these effects were not significant determinants of variations among normal ranges of strain values. There was no evidence of publication bias (P = .40). CONCLUSIONS: This study defines reference values of 2DSTE-derived LV strain in children on the basis of a meta-analysis. In healthy children, mean LV GLS was -20.2% (95% CI, -19.5% to -20.8%), mean GCS was -22.3% (95% CI, -19.9% to -24.6%), and mean GRS was 45.2% (95% CI, 38.3% to 51.7%). LV segmental longitudinal strain has a stable apex-to-base gradient that is preserved throughout maturation. Although variations among different reference ranges in this meta-analysis were not dependent on differences in demographic, clinical, or vendor parameters, age- and vendor-specific referenced ranges were established as well
    corecore