28 research outputs found

    Improved endothelial function after a modified harvesting technique of the internal thoracic artery

    Get PDF
    Objective: One of the most important factors in bypass surgery is the preservation of endothelial function in the arterial graft. It was of interest, therefore, whether a slightly modified preparation procedure during surgery could contribute to improved endothelial function of the graft. We compared the functional activity of internal thoracic arteries (ITA) prepared according to the traditional harvesting method with occlusion by a clip, dissection at the distal end and storage of the artery in papaverine until its implantation (CA) with the functional activity of arteries which were also prepared and wrapped in papaverine, but were left perfused and dissected immediately before their anastomoses (PA). Methods: Samples of ITA were obtained from a total number of 28 patients, undergoing bypass surgery, and randomly distributed into two groups. The arteries were cut into rings and suspended in organ baths, containing Krebs-Henseleit solution, for isometric tension recording. Cumulative concentration response curves were determined for the contractile agents endothelin-1 (ET-1), 5-hydroxytryptamine (5-HT), noradrenaline (NA) and potassium chloride (KCl) and the relaxant compounds acetylcholine (ACH) and sodium nitroprusside (SNP) during active tone induced by 30 mM KCl. Results: ET-1 and 5-HT stimulated rings from both groups within the same concentration ranges but elicited significantly (P<0.05) higher contractile responses in CA compared to PA. By contrast, concentration response curves for KCl and NA where nearly superimposable. On the other hand, maximal endothelium-dependent relaxant responses to ACH proved to be significantly stronger in PA (0.84±0.20 g) as compared to CA (0.31±0.05 g, P<0.05) while endothelium independent relaxant responses to SNP where similar in both groups. Conclusion: These data suggest that leaving the ITA perfused during harvesting might improve considerably the endothelial function of the graf

    Risks and benefits of optimised medical and revascularisation therapy in elderly patients with angina - on-treatment analysis of the TIME trial

    Get PDF
    Aim To assess treatment effects of optimised medical therapy and PCI or CABG surgery on one-year outcome in patients ⩾75 years old with chronic angina. Methods and Results On-treatment analysis of the TIME data: all re-vascularised patients (REVASC \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} n=174n=174 \end{document}: 112 randomised to revascularisation and 62 to drugs with late revascularisation) were compared to all patients on continued drug therapy (MED \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} n=127n=127 \end{document}: 86 randomised to drugs and 41 to revascularisation only). Baseline characteristics of both groups were similar (age 80±4 years). Risk of death at one year (adjusted hazard ratio (HR)=1.31; 95%-CI: 0.58-2.99; \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} P=0.52P=0.52 \end{document}) and of death/infarction (adjusted hazard ratio=1.77; 95%-CI 0.91-3.41; \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} P=0.09P=0.09 \end{document}) were comparable between REVASC and MED patients. Furthermore, the risk of death within 30 days was even slightly lower among REVASC patients (unadjusted hazard ratio=0.73; 95%-CI: 0.21-2.53; \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} P=0.98)P=0.98) \end{document}. Overall, REVASC patients had greater improvements in symptoms and well-being than MED patients \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} (P<0.01)(P{<}0.01) \end{document}. Surgical patients had similar mortality rates as angioplasty patients, but they also had greater symptomatic improvements \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} (P<0.01)(P{<}0.01) \end{document}. Conclusion Treated medically, elderly patients with chronic angina have a similarly high 30-day and one-year mortality as patients of the same age being re-vascularised; however, they can expect lower improvements in symptoms and well bein

    Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    Get PDF
    BACKGROUND: In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. METHODS: In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. RESULTS: A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 ± 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. CONCLUSION: Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery

    Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    No full text
    Abstract Background In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. Methods In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. Results A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 ± 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. Conclusion Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery.</p
    corecore