918 research outputs found

    Socially Disorganized Rural Communities

    Get PDF
    The article talks about the social disorganization of rural communities in the U.S. It is stated that family farming has been on the decline for decades, with the numbers of farmers dropping by 16 million since 1950 and farms decreasing by over 4 million during the past century. It is inferred that a part of a community\u27s history and way of life are being forfeited when local business are closing. According to the author, the theory of social disorganization emphasizes social integration and stability as necessary conditions for community. It offers some of the disadvantages of disorganized communities, such as the lack of collective efficacy

    Impact of pharmaceutical promotion on prescribing decisions of general practitioners in Eastern Turkey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Commercial sources of information are known to have greater influence than scientific sources on general practitioners' (GPs) prescribing behavior in under developed and developing countries. The study aimed to determine the self-reported impact of pharmaceutical promotion on the decision-making process of prescription of GPs in Eastern Turkey.</p> <p>Methods</p> <p>A cross-sectional, exploratory survey was performed among 152 GPs working in the primary health centers and hospitals in Erzurum province of Eastern Turkey in 2006. A self-administered structured questionnaire was used. The questionnaire included questions regarding sociodemographics, number of patients per day, time per patient, frequency of sales representative visits to GPs, participation of GPs in training courses on prescribing (in-service training, drug companies), factors affecting prescribing decision, reference sources concerning prescribing and self-reported and self-rated effect of the activities of sales representatives on GPs prescribing decisions.</p> <p>Results</p> <p>Of 152 subjects, 53.3% were male and 65.8% were working at primary health care centers, respectively. Mean patient per day was 58.3 ± 28.8 patients per GP. For majority of the GPs (73.7%), the most frequent resource used in case of any problems in prescribing process was drug guides of pharmaceutical companies. According to self-report of the GPs, their prescribing decisions were affected by participation in any training activity of drug companies, frequent visits by sales representatives, high number of patient examinations per day and low year of practice (p < 0.05 for all).</p> <p>Conclusion</p> <p>The results of this study suggest that for the majority of the GPs, primary reference sources concerning prescribing was commercial information provided by sales representatives of pharmaceutical companies, which were reported to be highly influential on their decision-making process of prescribing by GPs. Since this study was based on self-report, the influence reported by the GPs may have been underestimated.</p

    ICP curve morphology and intracranial flow-volume changes: a simultaneous ICP and cine phase contrast MRI study in humans

    Get PDF
    Background: The intracranial pressure (ICP) curve with its different peaks has been extensively studied, but the exact physiological mechanisms behind its morphology are still not fully understood. Both intracranial volume change (ΔICV) and transmission of the arterial blood pressure have been proposed to shape the ICP curve. This study tested the hypothesis that the ICP curve correlates to intracranial volume changes. Methods: Cine phase contrast magnetic resonance imaging (MRI) examinations were performed in neuro-intensive care patients with simultaneous ICP monitoring. The MRI was set to examine cerebral arterial inflow and venous cerebral outflow as well as flow of cerebrospinal fluid over the foramen magnum. The difference in total flow into and out from the cranial cavity (Flowtot) over time provides the ΔICV. The ICP curve was compared to the Flowtot and the ΔICV. Correlations were calculated through linear and logarithmic regression. Student’s t test was used to test the null hypothesis between paired samples. Results: Excluding the initial ICP wave, P1, the mean R2 for the correlation between the ΔICV and the ICP was 0.75 for the exponential expression, which had a higher correlation than the linear (p = 0.005). The first ICP peaks correlated to the initial peaks of Flowtot with a mean R2 = 0.88. Conclusion: The first part, or the P1, of the ICP curve seems to be created by the first rapid net inflow seen in Flowtot while the rest of the ICP curve seem to correlate to the ΔICV

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Penilaian Kinerja Keuangan Koperasi di Kabupaten Pelalawan

    Full text link
    This paper describe development and financial performance of cooperative in District Pelalawan among 2007 - 2008. Studies on primary and secondary cooperative in 12 sub-districts. Method in this stady use performance measuring of productivity, efficiency, growth, liquidity, and solvability of cooperative. Productivity of cooperative in Pelalawan was highly but efficiency still low. Profit and income were highly, even liquidity of cooperative very high, and solvability was good
    corecore