531 research outputs found

    An investigation of the relationship between BOLD and perfusion signal changes during epileptic generalised spike wave activity

    Get PDF
    In pathological conditions interpretation of functional magnetic resonance imaging (fMRI) results can be difficult. This is due to a reliance on the assumed coupling between neuronal activity and changes in cerebral blood flow (CBF) and oxygenation. We wanted to investigate the coupling between blood oxygen level dependant contrast (BOLD) and CBF time courses in epilepsy patients with generalised spike wave activity (GSW) to better understand the underlying mechanisms behind the EEG-fMRI signal changes observed, especially in regions of negative BOLD response (NBR). Four patients with frequent GSW were scanned with simultaneous electroencephalographic (EEG)-fMRI with BOLD and arterial spin labeling (ASL) sequences. We examined the relationship between simultaneous CBF and BOLD measurements by looking at the correlation of the two signals in terms of percentage signal change on a voxel-by-voxel basis. This method is not reliant on coincident activation. BOLD and CBF were positively correlated in patients with epilepsy during background EEG activity and GSW. The subject average value of the ΔCBF/ΔBOLD slope lay between +19 and +36 and also showed spatial variation which could indicate areas with altered vascular response. There was not a significant difference between ΔCBF/ΔBOLD during GSW, suggesting that neurovascular coupling to BOLD signal is generally maintained between states and, in particular, within areas of NBR

    Macrodamage Accumulation Model for a Human Femur

    Get PDF
    The objective of this study was to more fully understand the mechanical behavior of bone tissue that is important to find an alternative material to be used as an implant and to develop an accurate model to predict the fracture of the bone. Predicting and preventing bone failure is an important area in orthopaedics. In this paper, the macrodamage accumulation models in the bone tissue have been investigated. Phenomenological models for bone damage have been discussed in detail. In addition, 3D finite element model of the femur prepared from imaging data with both cortical and trabecular structures is delineated using MIMICS and ANSYS® and simulated as a composite structure. The damage accumulation occurring during cyclic loading was analyzed for fatigue scenario. We found that the damage accumulates sooner in the multiaxial than in the uniaxial loading condition for the same number of cycles, and the failure starts in the cortical bone. The damage accumulation behavior seems to follow a three-stage growth: a primary phase, a secondary phase of damage growth marked by linear damage growth, and a tertiary phase that leads to failure. Finally, the stiffness of the composite bone comprising the cortical and trabecular bone was significantly different as expected

    Group Key Manager on a Smart Card

    Full text link
    Only the abstract is available for this technical report.Group communication is as an important functionality, which needs to be supported by various communication technologies. Applications of group communication include IP (or application-level) multicast, wireless and/or ad-hoc networks, broadcast, conference calling, pay-per-view, and even such seemingly unrelated to networks areas as copy protection. For many, if not all, of these applications, security and trust play an important role. Securing group communication typically requires confidentiality and authentication, which typically rely on secret keys. Thus key management issues must be addressed. This paper describes an implementation of one approach to dynamic group key management, which is based on Logical Key Hierarchy or Subset-Cover approach [1,2]. Our approach achieves a dramatic reduction of the storage requirements for the Group Key Manager, and in particular allows all the secret key data to be stored on a smart-card. It also allows a number of subsequent improvements

    Hierarchical Structure and Properties of the Bone at Nano Level

    Get PDF
    Bone is a highly hierarchical complex structure that consists of organic and mineral components represented by collagen molecules (CM) and hydroxyapatite crystals (HAC), respectively. The nanostructure of bone can significantly affect its mechanical properties. There is a lack of understanding how collagen fibrils (CF) in different orientations may affect the mechanical properties of the bone. The objective of this study is to investigate the effect of interaction, orientation, and hydration on atomic models of the bone composed of collagen helix (CH) and HAC, using molecular dynamics simulations and therefrom bone-related disease origins. The results demonstrate that the mechanical properties of the bone are affected significantly by the orientation of the CF attributed to contact areas at 0° and 90° models. The molecular dynamics simulation illustrated that there is significant difference (p \u3c 0.005) in the ultimate tensile strength and toughness with respect to the orientation of the hydrated and un-hydrated CF. Additionally, the results indicated that having the force in a longitudinal direction (0°) provides more strength compared with the CF in the perpendicular direction (90°). Furthermore, the results show that substituting glycine (GLY) with any other amino acid affects the mechanical properties and strength of the CH, collagen–hydroxyapatite interface, and eventually affects the HAC. Generally, hydration dramatically influences bone tissue elastic properties, and any change in the orientation or any abnormality in the atomic structure of either the CM or the HAC would be the main reason of the fragility in the bone, affecting bone pathology

    BOLD and perfusion changes during epileptic generalised spike wave activity

    Get PDF
    It is unclear whether neurovascular coupling is maintained during epileptic discharges. Knowing this is important to allow appropriate inferences from functional imaging studies of epileptic activity. Recent blood oxygen level-dependent (BOLD) functional MRI (fMRI) studies have demonstrated negative BOLD responses (NBR) in frontal, parietal and posterior cingulate cortices during generalised spike wave activity (GSW). We hypothesized that GSW-related NBR commonly reflect decreased cerebral blood flow (CBF). We measured BOLD and cerebral blood flow responses using simultaneous EEG with BOLD and arterial spin label (ASL) fMRI at 3 T. Four patients with epilepsy were studied; two with idiopathic generalized epilepsy (IGE) and two with secondary generalized epilepsy (SGE). We found GSW-related NBR in frontal, parietal and posterior cingulate cortices. We measured the coupling between BOLD and CBF changes during GSW and normal background EEG and found a positive correlation between the simultaneously measured BOLD and CBF throughout the imaged volume. Frontal and thalamic activation were seen in two patients with SGE, concordant with the electro-clinical features of their epilepsy. There was striking reproducibility of the GSW-associated BOLD response in subjects previously studied at 1.5 T. Our results show a preserved relationship between BOLD and CBF changes during rest and GSW activity consistent with normal neurovascular coupling in patients with generalized epilepsy and in particular during GSW activity. Cortical activations appear to reflect areas of discharge generation whilst deactivations reflect changes in conscious resting state activity

    EEG–fMRI mapping of asymmetrical delta activity in a patient with refractory epilepsy is concordant with the epileptogenic region determined by intracranial EEG

    Get PDF
    We studied a patient with refractory focal epilepsy using continuous EEG-correlated fMRI. Seizures were characterized by head turning to the left and clonic jerking of the left arm, suggesting a right frontal epileptogenic region. Interictal EEG showed occasional runs of independent nonlateralized slow activity in the delta band with right frontocentral dominance and had no lateralizing value. Ictal scalp EEG had no lateralizing value. Ictal scalp EEG suggested right-sided central slow activity preceding some seizures. Structural 3-T MRI showed no abnormality. There was no clear epileptiform abnormality during simultaneous EEG–fMRI. We therefore modeled asymmetrical EEG delta activity at 1–3 Hz near frontocentral electrode positions. Significant blood oxygen level-dependent (BOLD) signal changes in the right superior frontal gyrus correlated with right frontal oscillations at 1–3 Hz but not at 4–7 Hz and with neither of the two frequency bands when derived from contralateral or posterior electrode positions, which served as controls. Motor fMRI activations with a finger-tapping paradigm were asymmetrical: they were more anterior for the left hand compared with the right and were near the aforementioned EEG-correlated signal changes. A right frontocentral perirolandic seizure onset was identified with a subdural grid recording, and electric stimulation of the adjacent contact produced motor responses in the left arm and after discharges. The fMRI localization of the left hand motor and the detected BOLD activation associated with modeled slow activity suggest a role for localization of the epileptogenic region with EEG–fMRI even in the absence of clear interictal discharges

    Hierarchical Structure, Properties and Bone Mechanics at Macro, Micro, and Nano Levels

    Get PDF
    This research focuses on the hierarchical structure of bone and associated mechanical properties at different scales to assess damage accumulation leading to premature failure, with or without instrumentation. In this work, an attempt was made to develop a framework of macro, micro, and nano damage accumulation models and implementing them to derive mechanical behavior of the bone. At macrolevel, retrospective evaluation of 313 subjects was conducted, and the damage of bone tissue was investigated with respect to subject demography including age, gender, race, body mass index (BMI), height and weight, and their role in initiating fracture. Experimental data utilized 28 human femoral bones implanted with cephalomedullary nails were used to develop damage prediction models. Investigation of three real life medical device failures identified the mechanical and clinical bases of bone failure. At the micro level, microdamage accumulation of the bone was investigated in 307 subjects and new effective morphological parameters at microscale were proposed. At the nano level, molecular dynamics simulation was performed to investigate the effect of interaction, orientation, and hydration on the atomic models of the bone composed of collagen helix and hydroxyapatite crystal. The results showed that bone density and maximum von Mises stress decreased drastically in elderly patients, implying fixation devices and implants used by the young cannot be used. The results also showed that the two-dimensional representation of the morphological parameters of the bone at microscale does not provide a realistic description of bone structure. Therefore, in this work, three-dimensional representations at microscale indicated that bone interconnectivity is higher in female patients than in male patients. Gender has a significant effect on microdamage distribution in the bone. More precautions should be taken into consideration for older female patients. Race should also be considered during modeling implants or suggesting therapeutic techniques. Caucasian subjects are more susceptible to bone fatigue failure than other races. The mechanical properties of bone are affected significantly by the orientation of the collagen fibril, which varies between ethnicities. Any change in the structure of the collagen-hydroxyapatite composite leads to variable bone diseases. There is significant difference in the ultimate tensile strength and toughness of the bone with respect to the orientation of the hydrated and un-hydrated collagen fibrils. Water content also influences the bone tissues’ elastic properties. The force in longitudinal direction (0°) provides more strength compared with the collagen fibril in the perpendicular direction (90°). Substituting Glycine with other amino acids affects the mechanical properties and strength of the collagen helix, collagen-hydroxyapatite interface, and eventually affecting hydroxyapatite crystal. Appropriate models developed in each category showing experimental and computational relationships and their application in selecting implant materials

    Static Hovering Realization for Multirotor Aerial Vehicles with Tiltable Propellers

    Full text link
    This paper presents a theoretical study on the ability of multi-rotor aerial vehicles (MRAVs) with tiltable propellers to achieve and sustain static hovering at different orientations. To analyze the ability of MRAVs with tiltable propellers to achieve static hovering, a novel linear map between the platform's control inputs and applied forces and moments is introduced. The relation between the introduced map and the platform's ability to hover at different orientations is developed. Correspondingly, the conditions for MRAVs with tiltable propellers to realize and sustain static hovering are detailed. A numerical metric is then introduced, which reflects the ability of MRAVs to sustain static hovering at different orientations. A subclass of MRAVs with tiltable propellers is defined as the Critically Statically Hoverable platforms (CSH), where CSH platforms are MRAVs that cannot sustain static hovering with fixed propellers, but can achieve static hovering with tilting propellers. Finally, extensive simulations are conducted to test and validate the above findings, and to demonstrate the effect of the proposed numerical metric on the platform's dynamics
    • …
    corecore