66 research outputs found

    Diagnosis of coronary stenosis with CT angiography comparison of automated computer diagnosis with expert readings.

    Get PDF
    RATIONALE AND OBJECTIVES: To compare computer-generated interpretation of coronary computed tomography angiography (cCTA) by commercially available COR Analyzer software with expert human interpretation. MATERIALS AND METHODS: This retrospective Health Insurance Portability and Accountability Act‑compliant study was approved by the institutional review board. Among 225 consecutive cCTA examinations, 207 were of adequate quality for automated evaluation. COR Analyzer interpretation was compared to human expert interpretation for detection of stenosis defined as ≥50% vessel diameter reduction in the left main, left anterior descending (LAD), circumflex (LCX), right coronary artery (RCA), or a branch vessel (diagonal, ramus, obtuse marginal, or posterior descending artery). RESULTS: Among 207 cases evaluated by COR Analyzer, human expert interpretation identified 48 patients with stenosis. COR Analyzer identified 44/48 patients (sensitivity 92%) with a specificity of 70%, a negative predictive value of 97% and a positive predictive value of 48%. COR Analyzer agreed with the expert interpretation in 75% of patients. With respect to individual segments, COR Analyzer detected 9/10 left main lesions, 33/34 LAD lesions, 14/15 LCX lesions, 27/31 RCA lesions, and 8/11 branch lesions. False-positive interpretations were localized to the left main (n = 16), LAD (n = 26), LCX (n = 21), RCA (n = 21), and branch vessels (n = 23), and were related predominantly to calcified vessels, blurred vessels, misidentification of vessels and myocardial bridges. CONCLUSIONS: Automated computer interpretation of cCTA with COR Analyzer provides high negative predictive value for the diagnosis of coronary disease in major coronary arteries as well as first-order arterial branches. False-positive automated interpretations are related to anatomic and image quality considerations

    A glance at imaging bladder cancer.

    Get PDF
    Purpose: Early and accurate diagnosis of Bladder cancer (BCa) will contribute extensively to the management of the disease. The purpose of this review was to briefly describe the conventional imaging methods and other novel imaging modalities used for early detection of BCa and outline their pros and cons. Methods: Literature search was performed on Pubmed, PMC, and Google scholar for the period of January 2014 to February 2018 and using such words as bladder cancer, bladder tumor, bladder cancer detection, diagnosis and imaging . Results: A total of 81 published papers were retrieved and are included in the review. For patients with hematuria and suspected of BCa, cystoscopy and CT are most commonly recommended. Ultrasonography, MRI, PET/CT using 18F-FDG or 11C-choline and recently PET/MRI using 18F-FDG also play a prominent role in detection of BCa. Conclusion: For initial diagnosis of BCa, cystoscopy is generally performed. However, cystoscopy can not accurately detect carcinoma insitu (CIS) and can not distinguish benign masses from malignant lesions. CT is used in two modes, CT and computed tomographic urography (CTU), both for dignosis and staging of BCa. However, they cannot differentiate T1 and T2 BCa. MRI is performed to diagnose invasive BCa and can differentiate muscle invasive bladder carcinoma (MIBC) from non-muscle invasive bladder carcinoma (NMIBC). However, CT and MRI have low sensitivity for nodal staging. For nodal staging PET/CT is preferred. PET/MRI provides better differentiation of normal and pathologic structures as compared with PET/CT. Nonetheless none of the approaches can address all issues related for the management of BCa. Novel imaging methods that target specific biomarkers, image BCa early and accurately, and stage the disease are warranted

    Characterization and Normal Measurements of the Left Ventricular Outflow Tract by ECG-gated Cardiac CT: Implications for Disorders of the Outflow Tract and Aortic Valve.

    Get PDF
    RATIONALE AND OBJECTIVES: Studies suggest that electrocardiographically gated coronary computed tomographic angiography provides a clear definition of the left ventricular outflow tract (LVOT), and normal LVOT morphology may not be round, as assumed when the continuity equation is applied during echocardiography. The aims of this study were to demonstrate the morphology of the LVOT on coronary computed tomographic angiography and to establish normal values for LVOT measurements. MATERIALS AND METHODS: Two independent readers retrospectively measured anterior-posterior (AP) and transverse diameters of the LVOT and performed LVOT planimetry on coronary computed tomographic angiographic studies of 106 consecutive patients with normal aortic valves. RESULTS: Excellent interobserver agreement was observed for all measurements (r = 0.78-0.94). The LVOT was ovoid, with a larger transverse diameter than AP diameter during diastole and systole (P \u3c .001). However, the ratio of AP diameter to transverse diameter was closer to 1.0 during systole (P \u3c .001). Mean indexed LVOT area was minimally larger in systole than in diastole (P = .01-.04) and was larger in men than in women during diastole (P ≤ .001) and systole (P ≤ .01). Mean LVOT area indexed to body surface area was 2.3 ± 0.5 cm(2)/m(2) in women and 2.6 ± 0.7 cm(2)/m(2) in men. LVOT area demonstrated significant correlation with aortic root diameter. CONCLUSIONS: The normal LVOT is ovoid in shape. LVOT is more circular during systole, but the AP diameter remains smaller than the transverse diameter throughout the cardiac cycle. The oval shape of the LVOT has important implications when LVOT area is calculated from LVOT diameters. Normal LVOT area values established in this study should facilitate diagnosis of the fixed component of LVOT obstruction

    Left atrial volume: comparison of 2D and 3D transthoracic echocardiography with ECG-gated CT angiography.

    Get PDF
    RATIONALE AND OBJECTIVES: Left atrial volume (LAV) measurement by conventional two-dimensional (2D) transthoracic echocardiography (TTE) may be limited by the geometric model, by suboptimal definition of left atrial endocardium, or by chamber foreshortening. Three-dimensional (3D) TTE is posited to eliminate chamber foreshortening, and LAV measurement by 3D TTE should be more reflective of true LAV. The aim of this study was to compare conventional 2D TTE and newer 3D TTE for measurements of LAV to multidetector computed tomographic (MDCT) measurements using automated chamber reconstruction (ACR). MATERIALS AND METHODS: Twenty-two subjects consented to undergo 2D TTE and 3D TTE immediately prior to or following coronary computed tomographic angiography. LAV was calculated from 2D TTE using the area-length method (ALM) and from 3D TTE with the ALM as well as with a 3D model. Electrocardiographically gated coronary computed tomographic angiography was performed in helical mode. LAV was measured using the ALM as well as ACR. RESULTS: LAV was significantly smaller by 2D TTE (80 ± 21 mL) and 3D-TTE (90 ± 24 mL with the ALM, 61 ± 16 mL with the 3D model) compared to MDCT ACR (120 ± 30 mL) (P \u3c .01). Correlation between MDCT ALM and MDCT ACR was excellent (mean Δ = -1.4 ± 14 mL, r = 0.91). Correlation with MDCT ACR was no better for 3D TTE (r = 0.80) than for 2D TTE (r = 0.80). CONCLUSIONS: LAV is underestimated by both 2D TTE and 3D TTE relative to coronary computed tomographic angiography. Excellent agreement between the ALM and ACR with MDCT imaging suggests that the geometric model plays a negligible role in the underestimation of LAV. Underestimation of LAV by echocardiography is likely related to suboptimal definition of left atrial contour

    Association between Medicaid expansion status and lung cancer screening exam growth: findings from the ACR lung cancer registry.

    Get PDF
    PURPOSE: To determine if Medicaid expansion is associated with increased volumes of lung cancer screenings. METHODS: A quasi-experimental study was performed to compare the annual growth rates in lung cancer screenings between states that expanded Medicaid (n = 31) versus those that did not (n = 17). Using the American College of Radiology Lung Cancer Screening Registry, we calculated the average annual growth rate between 2016 and 2019 for both groups. Secondary analyses between these two groups also included calculations of the percentages of studies considered appropriate by USPSTF criteria. RESULTS: No significant difference was identified in the average annual growth in lung cancer screenings between Medicaid expanding and non-expanding states (57.6%, 50.3%, P = 0.51). No difference was observed in the percentage of studies considered appropriate (Medicaid expanding = 89.6%, non-expanding = 90.2%, P = 0.72). At baseline, there were socioeconomic differences between both groups of states. Medicaid expanding states had a more urban population (76.5% versus 67.9%, P = 0.05) and higher average incomes (56,947,56,947, 49,876, P \u3c 0.05). CONCLUSION: No association is found between Medicaid expansion and increasing volumes of lung cancer screening exams. Although no data is available in the registry for screening exams before the implementation of Medicaid expansion (2014), most nationwide estimates of lung screening rates report a low baseline (\u3c5%). Furthermore, despite being advantaged in other ways, such as with a more urban population or with higher incomes, the Medicaid expansion cohort does not demonstrate a higher growth rate. These findings suggest Medicaid expansion alone will not increase lung cancer screenings

    Decision analytic model for evaluation of suspected coronary disease with stress testing and coronary CT angiography.

    Get PDF
    RATIONALE AND OBJECTIVES: The aim of this study was to apply a decision analytic model for the evaluation of coronary artery disease (CAD) to define the optimal utilization of coronary computed tomographic angiography (cCTA) and stress testing. MATERIALS AND METHODS: The model tested in this study assumes that CAD is evaluated with a stress test and/or cCTA and that a patient with positive evaluation results undergoes cardiac catheterization. On the basis of values of sensitivity, specificity, and radiation dose from the published literature and test costs from the Medicare fee schedule, a decision tree model was constructed as a function of disease prevalence. RESULTS: The false-negative rate is lowest when cCTA is used as an isolated test. The false-positive rate is minimized when cCTA is used in combination with stress echocardiography. Effective radiation is minimized by use of stress electrocardiography or stress echocardiography alone or prior to cCTA. When the pretest probability of CAD is low, a strategy that uses stress echocardiography followed by cCTA minimizes the false-positive rate and effective radiation exposure, with relatively low imaging costs and with a false-negative rate only slightly higher than a strategy including stress myocardial scintigraphy. As the pretest probability of CAD increases above 20%, the false-negative rate of stress echocardiography followed by cCTA increases by \u3e5% relative to cCTA alone. CONCLUSION: Effective radiation dose and imaging costs for the workup of CAD may be minimized by an appropriate combination of stress testing and cCTA. A strategy that uses stress echocardiography followed by cCTA is most appropriate for the evaluation of low-risk patients with CAD with a pretest probability \u3c 20%, while cCTA alone may be more appropriate in intermediate-risk patients

    Sonoelastography of the Common Flexor Tendon of the Elbow with Histologic Agreement: A Cadaveric Study.

    Get PDF
    Purpose To determine the correlation of the results of conventional B-mode ultrasonography (US) and compression sonoelastography with histologic results in common flexor tendons of the elbow in human cadavers. Materials and Methods Twenty-five common flexor tendons were evaluated in 16 fresh, unembalmed cadavers of 11 women with a median age of 85 years (range, 71-101 years) and five men with a median age of 78 years (range, 70-88 years). Informed consent was provided according to the last will of the donors. B-mode US results were classified as grade 1, normal tendon with homogeneous fibrillar pattern; grade 2, tendon thickening or hypoechoic areas and/or calcifications in less than 30% of the tendon; or grade 3, hypoechoic areas and/or calcifications greater than 30% of the tendon. Sonoelastographic results were grade 1, blue (hardest) to green (hard); grade 2, yellow (soft); and grade 3, red (softest). The intraclass correlation coefficient was calculated to determine agreement with histologic findings for each B-mode US, sonoelastographic, and combined B-mode US and sonoelastographic examination. Histologic results were grade 1, normal, with parallel fibrillar pattern; grade 2, mild tendinopathy, with cellular infiltration, angiogenesis, or fatty vacuoles; or grade 3, severe tendinopathy, with loss of parallel collagen structure and necrosis. Results Histologic alterations were detected in 44% (11 of 25) of biopsy specimens. Intraclass correlation with histologic results was 0.57 for B-mode US, 0.68 for sonoelastography, and 0.84 for the combination of the two approaches. Conclusion The addition of sonoelastography to B-mode US provided statistically significant improvement in correlation with histologic results compared with the use of B-mode US alone (P \u3c .02). (©) RSNA, 2016 Online supplemental material is available for this article

    Cardiac risk factors and risk scores vs cardiac computed tomography angiography: a prospective cohort study for triage of ED patients with acute chest pain.

    Get PDF
    OBJECTIVE: The objective of the study is to evaluate cardiac risk factors and risk scores for prediction of coronary artery disease (CAD) and adverse outcomes in an emergency department (ED) population judged to be at low to intermediate risk for acute coronary syndrome. METHODS: Informed consent was obtained from consecutive ED patients who presented with chest pain and were evaluated with coronary computed tomography angiography (cCTA). Cardiac risk factors, clinical presentation, electrocardiogram, and laboratory studies were recorded; the Thrombolysis in Myocardial Infarction (TIMI) and Global Registry of Acute Coronary Events (GRACE) scores were tabulated. Coronary computed tomography angiography findings were rated on a 6-level plaque burden scale and classified for significant CAD (stenosis ≥50%). Adverse cardiovascular outcomes were recorded at 30 days. RESULTS: Among 250 patients evaluated by cCTA, 143 (57%) had no CAD, 64 (26%) demonstrated minimal plaque (70% stenosis). Six patients developed adverse cardiovascular outcomes. Among traditional cardiac risk factors, only age (older) and sex (male) were significant independent predictors of CAD. Correlation with CAD was poor for the TIMI (r = 0.12) and GRACE (r = 0.09-0.23) scores. The TIMI and GRACE scores were not useful to predict adverse outcomes. Coronary computed tomography angiography identified severe CAD in all subjects with adverse outcomes. CONCLUSION: Among ED patients who present with chest pain judged to be at low to intermediate risk for acute coronary syndrome, traditional risk factors are not useful to stratify risk for CAD and adverse outcomes. Coronary computed tomography angiography is an excellent predictor of CAD and outcome

    Potentials and limitations of real-time elastography for prostate cancer detection: a whole-mount step section analysis.

    Get PDF
    OBJECTIVES: To evaluate prostate cancer (PCa) detection rates of real-time elastography (RTE) in dependence of tumor size, tumor volume, localization and histological type. MATERIALS AND METHODS: Thirdy-nine patients with biopsy proven PCa underwent RTE before radical prostatectomy (RPE) to assess prostate tissue elasticity, and hard lesions were considered suspicious for PCa. After RPE, the prostates were prepared as whole-mount step sections and were compared with imaging findings for analyzing PCa detection rates. RESULTS: RTE detected 6/62 cancer lesions with a maximum diameter of 0-5 mm (9.7%), 10/37 with a maximum diameter of 6-10 mm (27%), 24/34 with a maximum diameter of 11-20 20 mm (70.6%), 14/14 with a maximum diameter of \u3e20 mm (100%) and 40/48 with a volume ≥0.2 cm(3) (83.3%). Regarding cancer lesions with a volume ≥ 0.2 cm³ there was a significant difference in PCa detection rates between Gleason scores with predominant Gleason pattern 3 compared to those with predominant Gleason pattern 4 or 5 (75% versus 100%; P = 0.028). CONCLUSIONS: RTE is able to detect PCa of significant tumor volume and of predominant Gleason pattern 4 or 5 with high confidence, but is of limited value in the detection of small cancer lesions

    Comparison of contrast enhanced color Doppler targeted biopsy to conventional systematic biology: Impact on Gleason score

    Get PDF
    Purpose: Prostate cancer grading with Gleason score is an important prognostic factor. This prospective randomized study compares ultrasound systematic biopsy vs contrast enhanced color Doppler targeted biopsy for the impact on Gleason score findings. Materials and Methods: We examined 690 men (mean age 56 years, range 41 to 77) with a serum total prostate specific antigen of 1.25 ng/ml or greater, a free-to-total prostate specific antigen ratio less than 18% and/or a suspicious digital rectal examination. Contrast enhanced color Doppler targeted biopsies with a limited number of cores (5 or less) were performed in hypervascular areas of the peripheral zone during administration of the ultrasound contrast agent SonovueTM(Bracco, Milano, Italy). Ten systematic biopsies were obtained in a standard spatial distribution. Cancer detection rates and Gleason score were compared. Results: Prostate cancer was identified in 221 of 690 subjects (32%) with a mean prostate specific antigen of 4.6 ng/ml (range 1.4 to 35.0). Prostate cancer was detected in 180 of 690 subjects (26%) with contrast enhanced color Doppler targeted biopsy and in 166 of 690 patients (24%) with systematic ultrasound biopsy. The Gleason score of all 180 cancers detected on contrast enhanced color Doppler targeted biopsy was 6 or higher (mean 6.8). The Gleason score of all 166 cancers detected on systematic biopsy ranged from 4 to 6 and mean Gleason score was 5.4. Contrast enhanced color Doppler targeted biopsy detected significantly higher Gleason scores compared to systematic biopsy (Wilcoxon rank sum test p \u3c0.003). Conclusions: Contrast enhanced color Doppler targeted biopsy detected cancers with higher Gleason scores and more cancer than systematic biopsy. Therefore, contrast enhanced color Doppler seems to be helpful in the grading of prostate cancer, which is important for defining prognosis and deciding treatment
    corecore