312 research outputs found

    Assessment of aortic regurgitation by transesophageal color Doppler imaging of the vena contracta: validation against an intraoperative aortic flow probe

    Get PDF
    AbstractOBJECTIVESThis study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV).BACKGROUNDColor Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity of valvular regurgitation. This study evaluated the accuracy of VC imaging of AR by transesophageal echocardiography (TEE).METHODSA transit-time flow probe was placed on the ascending aorta during cardiac surgery in 24 patients with AR. The flow probe was used to measure RgF and RgV simultaneously during VC imaging by TEE. Flow probe and VC imaging were interpreted separately and in blinded fashion.RESULTSA good correlation was found between VC width and RgF (r = 0.85) and RgV (r = 0.79). All six patients with VC width >6 mm had a RgF >0.50. All 18 patients with VC width <5 mm had a RgF <0.50. Vena contracta area also correlated well with both RgF (r = 0.81) and RgV (r = 0.84). All six patients with VC area >7.5 mm2had a RgF >0.50, and all 18 patients with a VC area <7.5 mm2had a RgF <0.50. In a subset of nine patients who underwent afterload manipulation to increase diastolic blood pressure, RgV increased significantly (34 ± 26 ml to 41 ± 27 ml, p = 0.042) while VC width remained unchanged (5.4 ± 2.8 mm to 5.4 ± 2.8 mm, p = 0.41).CONCLUSIONSVena contracta imaging by TEE color flow mapping is an accurate marker of AR severity. Vena contracta width and VC area correlate well with RgF and RgV obtained by intraoperative flow probe. Vena contracta width appears to be less afterload-dependent than RgV

    Does Digoxin Provide Additional Hemodynamic and Autonomic Benefit at Higher Doses in Patients With Mild to Moderate Heart Failure and Normal Sinus Rhythm?

    Get PDF
    AbstractObjectives. This study sought to examine the hemodynamic and autonomic dose response to digoxin.Background. Previous studies have demonstrated an increase in contractility and heart rate variability with digitalis preparations. However, little is known about the dose-response to digoxin, which has a narrow therapeutic window.Methods. Nineteen patients with moderate heart failure and a left ventricular ejection fraction <0.45 were studied hemodynamically using echocardiography and blood pressure at baseline and after 2 weeks of low dose (0.125 mg daily) and 2 weeks of moderate dose digoxin (0.25 mg daily). Loading conditions were altered with nitroprusside at each study. Autonomic function was studied by assessing heart rate variability on 24-h Holter monitoring and plasma norepinephrine levels during supine rest.Results. Low dose digoxin provided a significant increase in ventricular performance, but no further increase was seen with the moderate dose. Low dose digoxin reduced heart rate and increased heart rate variability. Moderate dose digoxin produced no additional increase in heart rate variability or reduction in sympathetic activity, as manifested by heart rate, plasma norepinephrine or low frequency/high frequency power ratio. In addition, we did not find that either low or moderate dose digoxin increased parasympathetic activity.Conclusions. We conclude that moderate dose digoxin provides no additional hemodynamic or autonomic benefit for patients with mild to moderate heart failure over low dose digoxin. Because higher doses of digoxin may predispose to arrhythmogenesis, lower dose digoxin should be considered in patients with mild to moderate heart failure.(J Am Coll Cardiol 1997;29:1206–13

    Primary results of long-term outcomes in the MOMENTUM 3 pivotal trial and continued access protocol study phase: a study of 2200 HeartMate 3 left ventricular assist device implants

    Get PDF
    AIM: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal-flow pump, over the HeartMate II axial-flow pump. We now evaluate HM3 LVAD outcomes in a single-arm prospective continuous access protocol (CAP) post-pivotal trial study. METHODS AND RESULTS: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2-year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71-1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra-aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68-1.16, P = 0.38). In a pooled analysis, the 2-year primary endpoint was similar between INTERMACS profiles 1-2 (\u27unstable\u27 advanced heart failure), profile 3 (\u27stable\u27 on inotropic therapy), and profiles 4-7 (\u27stable\u27 ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88-0.98, P = 0.006), with consequent decrease in hospitalization. CONCLUSIONS: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial

    Variability in Blood Pressure Assessment in Patients Supported with the HeartMate 3TM

    Get PDF
    Targeted blood pressure (BP) control is a goal of left ventricular assist device medical management, but the interpretation of values obtained from noninvasive instruments is challenging. In the MOMENTUM 3 Continued Access Protocol, paired BP values in HeartMate 3 (HM3) patients were compared from arterial (A)-line and Doppler opening pressure (DOP) (319 readings in 261 patients) and A-line and automated cuff (281 readings in 247 patients). Pearson (R) correlations between A-line mean arterial (MAP) and systolic blood pressures (SBP) were compared with DOP and cuff measures according to the presence (\u3e1 pulse in 5 seconds) or absence of a palpable radial pulse. There were only moderate correlations between A-line and noninvasive measurements of SBP (DOP R = 0.58; cuff R = 0.47) and MAP (DOP R = 0.48; cuff R = 0.37). DOP accuracy for MAP estimation, defined as the % of readings within ± 10 mmHg of A-line MAP, decreased from 80% to 33% for DOP ≀ 90 vs. \u3e90 mmHg, and precision also diminished (mean absolute difference [MAD] increased from 6.3 ± 5.6 to 16.1 ± 11.4 mmHg). Across pulse pressures, cuff MAPs were within ±10 mmHg of A-line 62.9%-68.8% of measures and MADs were negligible. The presence of a palpable pulse reduced the accuracy and precision of the DOP-MAP estimation but did not impact cuff-MAP accuracy or precision. In summary, DOP may overestimate MAP in some patients on HM3 support. Simultaneous use of DOP and automated cuff and radial pulse may be needed to guide antihypertensive medication titration in outpatients on HM3 support

    Pharmacology of DB844, an Orally Active aza Analogue of Pafuramidine, in a Monkey Model of Second Stage Human African Trypanosomiasis

    Get PDF
    Novel drugs to treat human African trypanosomiasis (HAT) are still urgently needed despite the recent addition of nifurtimox-eflornithine combination therapy (NECT) to WHO Model Lists of Essential Medicines against second stage HAT, where parasites have invaded the central nervous system (CNS). The pharmacology of a potential orally available lead compound, N-methoxy-6-{5-[4-(N-methoxyamidino) phenyl]-furan-2-yl}-nicotinamidine (DB844), was evaluated in a vervet monkey model of second stage HAT, following promising results in mice. DB844 was administered orally to vervet monkeys, beginning 28 days post infection (DPI) with Trypanosoma brucei rhodesiense KETRI 2537. DB844 was absorbed and converted to the active metabolite 6-[5-(4-phenylamidinophenyl)-furanyl-2-y​l]-nicotinamide(DB820), exhibiting plasma Cmax values of 430 and 190 nM for DB844 and DB820, respectively, after the 14th dose at 6 mg/kg qd. A 100-fold reduction in blood trypanosome counts was observed within 24 h of the third dose and, at the end of treatment evaluation performed four days post the last drug dose, trypanosomes were not detected in the blood or cerebrospinal fluid of any monkey. However, some animals relapsed during the 300 days of post treatment monitoring, resulting in a cure rate of 3/8 (37.5%) and 3/7 (42.9%) for the 5 mg/kg×10 days and the 6 mg/kg×14 days dose regimens respectively. These DB844 efficacy data were an improvement compared with pentamidine and pafuramidine both of which were previously shown to be non-curative in this model of CNS stage HAT. These data show that synthesis of novel diamidines with improved activity against CNS-stage HAT was possible.This investigation received financial support from the Bill and Melinda Gates Foundation through the Consortium for Parasitic Drug Development

    Defining Ecological Drought for the Twenty-First Century

    Get PDF
    THE RISING RISK OF DROUGHT. Droughts of the twenty-first century are characterized by hotter temperatures, longer duration, and greater spatial extent, and are increasingly exacerbated by human demands for water. This situation increases the vulnerability of ecosystems to drought, including a rise in drought-driven tree mortality globally (Allen et al. 2015) and anticipated ecosystem transformations from one state to another—for example, forest to a shrubland (Jiang et al. 2013). When a drought drives changes within ecosystems, there can be a ripple effect through human communities that depend on those ecosystems for critical goods and services (Millar and Stephenson 2015). For example, the “Millennium Drought” (2002–10) in Australia caused unanticipated losses to key services provided by hydrological ecosystems in the Murray–Darling basin—including air quality regulation, waste treatment, erosion prevention, and recreation. The costs of these losses exceeded AUD $800 million, as resources were spent to replace these services and adapt to new drought-impacted ecosystems (Banerjee et al. 2013). Despite the high costs to both nature and people, current drought research, management, and policy perspectives often fail to evaluate how drought affects ecosystems and the “natural capital” they provide to human communities. Integrating these human and natural dimensions of drought is an essential step toward addressing the rising risk of drought in the twenty-first century

    HVAD to HeartMate 3 left ventricular assist device exchange: Best practices recommendations

    Get PDF
    The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices

    Colorectal cancer screening, perceived discrimination, and low-income and trust in doctors: a survey of minority patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Completion of colorectal cancer (CRC) screening testing is lower among low-income and minority groups than the population as a whole. Given the multiple cancer screening health disparities known to exist within the U.S., this study investigated the relationship between perceived discrimination, trust in most doctors, and completion of Fecal Occult Blood Testing (FOBT) among a low-income, minority primary care population in an urban setting.</p> <p>Methods</p> <p>We recruited a convenience sample of adults over age 40 (n = 282) from a federally qualified community health center (70% African American). Participants completed a survey which included measures of trust in most doctors, perceived discrimination, demographics and report of cancer screening.</p> <p>Results</p> <p>Participants reported high levels of trust in most doctors, regardless of sex, race, education or income. High trust was associated with low perceived discrimination (p < 0.01). The trend was for older participants to express more trust (p = 0.09) and less perceived discrimination (p < 0.01). Neither trust nor discrimination was associated with race or education. Trust was higher among participants over 50 who were up-to-date on FOBT screening vs. those who were not (31 vs. 29 (median), p < 0.05 by T-test). Among those over 50, up-to-date FOBT screening was nearly associated with high trust (p < 0.06; 95% CI 0.99, 1.28) and low perceived discrimination (p < 0.01; 95% CI 0.76, 0.96). Nevertheless, in multivariate-modeling, age and income explained FOBT completion better than race, trust and discrimination.</p> <p>Conclusion</p> <p>Perceived discrimination was related to income, but not race, suggesting that discrimination is not unique to minorities, but common to those in poverty. Since trust in most doctors trended toward being related to age, FOBT screening could be negatively influenced by low trust and perceived discrimination in health care settings. A failure to address these issues in middle-aged, low income individuals could exacerbate future disparities in CRC screening.</p

    Special Considerations in the Care of Women With Advanced Heart Failure

    Get PDF
    Advanced heart failure (AHF) is associated with increased morbidity and mortality, and greater healthcare utilization. Recognition requires a thorough clinical assessment and appropriate risk stratification. There are persisting inequities in the allocation of AHF therapies. Women are less likely to be referred for evaluation of candidacy for heart transplantation or left ventricular assist device despite facing a higher risk of AHF-related mortality. Sex-specific risk factors influence progression to advanced disease and should be considered when evaluating women for advanced therapies. The purpose of this review is to discuss the role of sex hormones on the pathophysiology of AHF, describe the clinical presentation, diagnostic evaluation and definitive therapies of AHF in women with special attention to pregnancy, lactation, contraception and menopause. Future studies are needed to address areas of equipoise in the care of women with AHF
    • 

    corecore