12 research outputs found

    Promoting Compliance with Inhaler Use in Asthma Patients

    Get PDF
    Introduction: Asthma is a chronic airways disease characterised by recurrent attacks of breathlessness and wheezing, which vary in severity and frequency from person to person. Symptoms may occur several times a day or week in affected individuals, and for some people symptoms become worse during physical activity or at night. Intermittent relapse from periods o f stable asthma is the usual clinical course for most adults. Incorrect inhaler usage is a significant problem in asthma management, resulting in poor control o f asthma symptoms. The ability o f patients to correctly use their inhaler might be directly linked to inhaler technique education. Education may result in better inhalation technique, improved compliance and asthma control. The economic burden o f asthma is very substantial and is one of the highest among chronic diseases. Research question: “What is the impact of a nurse-led education programme in promoting compliance with inhaler use in patients with Asthma?” Methodology: This is a quantitative study engaging a quasi-experimental pre-test and post-test design, but with a follow-up period added. A cohort o f 21 patients who met the inclusion criteria were recruited from the Out-Patient Department over a period o f six months. During each visit, participants were asked to demonstrate how they took their inhaler. Any errors in technique were identified and rectified. Their demonstration was measured through observation and with the use of an Inhaler Proficiency Schedule (IPS). The participants were also asked a series of specific questions in relation to their condition, confidence level with selfadministration o f their inhaler, and adherence to prescribed frequency o f use. Results: The findings in this study show that inhaler education improves technique, promotes compliance and increases participant confidence levels in taking an inhaler, and as a result asthma symptoms improve. It also emerged that participants believed they were taking their inhaler correctly and so assumed that education drives were not targeted at them. Implications: There were implications of the findings on the role and function of nurses, patients, pharmacists and the Health Service

    Predicting asthma exacerbations employing remotely monitored adherence

    Get PDF
    This Letter investigated the efficacy of a decision-support system, designed for respiratory medicine, at predicting asthma exacerbations in a multi-site longitudinal randomised control trial. Adherence to inhaler medication was acquired over 3 months from patients with asthma employing a dose counter and a remote monitoring adherence device which recorded participant\u27s inhaler use: n = 184 (23,656 audio files), 61% women, age (mean ± sd) 49.3 ± 16.4. Data on occurrence of exacerbations was collected at three clinical visits, 1 month apart. The relative risk of an asthma exacerbation for those with good and poor adherence was examined employing a univariate and multivariate modified Poisson regression approach; adjusting for age, gender and body mass index. For all months dose counter adherence was significantly (p \u3c 0.01) higher than remote monitoring adherence. Overall, those with poor adherence had a 1.38 ± 0.34 and 1.42 ± 0.39 (remotely monitored) and 1.25 ± 0.32 and 1.18 ± 0.31 (dose counter) higher relative risk of an exacerbation in model 1 and model 2, respectively. However, this was not found to be statistically significantly different. Remotely monitored adherence holds important clinical information and future research should focus on refining adherence and exacerbation measures. Decision-support systems based on remote monitoring may enhance patient-physician communication, possibly reducing preventable adverse events

    A protocol for a randomised clinical trial of the effect of providing feedback on inhaler technique and adherence from an electronic device in patients with poorly controlled severe asthma.

    Get PDF
    INTRODUCTION: In clinical practice, it is difficult to distinguish between patients with refractory asthma from those with poorly controlled asthma, where symptoms persist due to poor adherence, inadequate inhaler technique or comorbid diseases. We designed an audio recording device which, when attached to an inhaler, objectively identifies the time and technique of inhaler use, thereby assessing both aspects of adherence. This study will test the hypothesis that feedback on these two aspects of adherence when passed on to patients improves adherence and helps clinicians distinguish refractory from difficult-to-control asthma. METHODS: This is a single, blind, prospective, randomised, clinical trial performed at 5 research centres. Patients with partially controlled or uncontrolled severe asthma who have also had at least one severe asthma exacerbation in the prior year are eligible to participate. The effect of two types of nurse-delivered education interventions to promote adherence and inhaler technique will be assessed. The active group will receive feedback on their inhaler technique and adherence from the new device over a 3-month period. The control group will also receive training in inhaler technique and strategies to promote adherence, but no feedback from the device. The primary outcome is the difference in actual adherence, a measure that incorporates time and technique of inhaler use between groups at the end of the third month. Secondary outcomes include the number of patients who remain refractory despite good adherence, and differences in the components of adherence after the intervention. Data will be analysed on an intention-to-treat and a per-protocol basis. The sample size is 220 subjects (110 in each group), and loss to follow-up is estimated at 10% which will allow results to show a 10% difference (0.8 power) in adherence between group means with a type I error probability of 0.05. TRIAL REGISTRATION NUMBER: NCT01529697; Pre-results

    Use of digital measurement of medication adherence and lung function to guide the management of uncontrolled asthma (INCA Sun):a multicentre, single-blinded, randomised clinical trial

    Get PDF
    BACKGROUND: The clinical value of using digital tools to assess adherence and lung function in uncontrolled asthma is not known. We aimed to compare treatment decisions guided by digitally acquired data on adherence, inhaler technique, and peak flow with existing methods.METHODS: A 32-week prospective, multicentre, single-blinded, parallel, randomly controlled trial was done in ten severe asthma clinics across Ireland, Northern Ireland, and England. Participants were 18 years or older, had uncontrolled asthma, asthma control test (ACT) score of 19 or less, despite treatment with high-dose inhaled corticosteroids, and had at least one severe exacerbation in the past year despite high-dose inhaled corticosteroids. Patients were randomly assigned in a 1:1 ratio to the active group or the control group, by means of a computer-generated randomisation sequence of permuted blocks of varying sizes (2, 4, and 6) stratified by fractional exhaled nitric oxide (FeNO) concentration and recruitment site. In the control group, participants were masked to their adherence and errors in inhaler technique data. A statistician masked to study allocation did the statistical analysis. After a 1-week run-in period, both groups attended three nurse-led education visits over 8 weeks (day 7, week 4, and week 8) and three physician-led treatment adjustment visits at weeks 8, 20, and 32. In the active group, treatment adjustments during the physician visits were informed by digital data on inhaler adherence, twice daily digital peak expiratory flow (ePEF), patient-reported asthma control, and exacerbation history. Treatment was adjusted in the control group on the basis of pharmacy refill rates (a measure of adherence), asthma control by ACT questionnaire, and history of exacerbations and visual management of inhaler technique. Both groups used a digitally enabled Inhaler Compliance Assessment (INCA) and PEF. The primary outcomes were asthma medication burden measured as proportion of patients who required a net increase in treatment at the end of 32 weeks and adherence rate measured in the last 12 weeks by area under the curve in the intention-to-treat population. The safety analyses included all patients who consented for the trial. The trial is registered with ClinicalTrials.gov, NCT02307669 and is complete.FINDINGS: Between Oct 25, 2015, and Jan 26, 2020, of 425 patients assessed for eligibility, 220 consented to participate in the study, 213 were randomly assigned (n=108 in the active group; n=105 in the control group) and 200 completed the study (n=102 in the active group; n=98 in the control group). In the intention-to-treat analysis at week 32, 14 (14%) active and 31 (32%) control patients had a net increase in treatment compared with baseline (odds ratio [OR] 0·31 [95% CI 0·15-0·64], p=0·0015) and 11 (11%) active and 21 (21%) controls required add-on biological therapy (0·42 [0·19-0·95], p=0·038) adjusted for study site, age, sex, and baseline FeNO. Three (16%) of 19 active and 11 (44%) of 25 control patients increased their medication from fluticasone propionate 500 μg daily to 1000 μg daily (500 μg twice a day; adjusted OR 0·23 [0·06-0·87], p=0·026). 26 (31%) of 83 active and 13 (18%) of 73 controls reduced their medication from fluticasone propionate 1000 μg once daily to 500 μg once daily (adjusted OR 2·43 [1·13-5·20], p=0·022. Week 20-32 actual mean adherence was 64·9% (SD 23·5) in the active group and 55·5% (26·8) in the control group (between-group difference 11·1% [95% CI 4·4-17·9], p=0·0012). A total of 29 serious adverse events were recorded (16 [55%] in the active group, and 13 [45%] in the control group), 11 of which were confirmed as respiratory. None of the adverse events reported were causally linked to the study intervention, to the use of salmeterol-fluticasone inhalers, or the use of the digital PEF or INCA.INTERPRETATION: Evidence-based care informed by digital data led to a modest improvement in medication adherence and a significantly lower treatment burden.FUNDING: Health Research Board of Ireland, Medical Research Council, INTEREG Europe, and an investigator-initiated project grant from GlaxoSmithKline.</p

    A novel statistical method for assessing effective adherence to medication and calculating optimal drug dosages.

    No full text
    We derive a novel model-based metric for effective adherence to medication, and validate it using data from the INhaler Compliance Assessment device (INCATM). This technique employs dose timing data to estimate the threshold drug concentration needed to maintain optimal health.The parameters of the model are optimised against patient outcome data using maximum likelihood methods. The model is fitted and validated by secondary analysis of two independent datasets from two remote-monitoring studies of adherence, conducted through clinical research centres of 5 Irish hospitals. Training data came from a cohort of asthma patients (~ 47,000 samples from 218 patients). Validation data is from a cohort of 204 patients with COPD recorded between 2014 and 2016.The time above threshold measure is strongly predictive of adverse events (exacerbations) in COPD patients (Odds Ratio of exacerbation = 0.52 per SD increase in adherence, 95% Confidence Interval [0.34-0.79]). This compares well with the best known previous method, the Area Under the dose-time Curve (AUC) (Odds Ratio = 0.69, 95% Confidence Interval [0.48-0.99]). In addition, the fitted value of the dose threshold (0.56 of prescribed dosage) suggests that prescribed doses may be unnecessarily high given good adherence.The resulting metric accounts for missed doses, dose-timing errors, and errors in inhaler technique, and provides enhanced predictive validity in comparison to previously used measures. In addition, the method allows us to estimate the correct dosage required to achieve the effect of the medication using the patients' own adherence data and outcomes. The adherence score does depend not on sex or other demographic factors suggesting that effective adherence is driven by individual behavioural factors

    The effects of parameters <i>θ</i> and <i>β</i> on the threshold function.

    No full text
    <p>For large values of <i>β</i> the function becomes step-like, while for small values it is smoother, and approximately linear. Changes in <i>θ</i> shift the function to the right or left.</p

    Simulated absorbed ICS concentrations for two patients using Seretide inhalers, with target threshold concentration, <i>θ</i>.

    No full text
    <p>In both cases the patient has received 4 doses over the period shown. The patient in (a) is more successful in maintaining above-target concentration, while in (b) the concentration drops below target on several occasions.</p
    corecore