58 research outputs found

    A Contamination Sensor Based on an Array of Microfibers with Nanoscale-Structured Film

    Get PDF
    A contamination sensor based on an array of microfibers with nanoscale-structured film using evanescent field is proposed and demonstrated theoretically and experimentally. When the molecular contaminants deposit on the nanoscale-structured film, the refractive index of the film will change and the additional loss will be produced due to the disturbance of evanescent field. The possibility of the sensor is demonstrated theoretically by using three-dimensional finite-difference time domain (3D-FDTD). The corresponding experiments have also been carried out in order to demonstrate the theoretical results. Microfibers are fabricated by using hydrogen-oxygen flame-heated scanning fiber drawing method and the nanoscale-structured film coated on the surface of microfibers is deposited by using dip coating process. Then an array of microfibers is assembled to demonstrate the feasibility of the device. The experimental results show that contaminants detection with the device can agree well with the results measured by the laser-scattering particle counter, which demonstrates the feasibility of the new type of contaminant sensor. The device can be used to monitor contaminants on-line in the high-power laser system

    Solving Gravity Anomaly Matching Problem Under Large Initial Errors in Gravity Aided Navigation by Using an Affine Transformation Based Artificial Bee Colony Algorithm

    Get PDF
    Gravity aided inertial navigation system (GAINS), which uses earth gravitational anomaly field for navigation, holds strong potential as an underwater navigation system. The gravity matching algorithm is one of the key factors in GAINS. Existing matching algorithms cannot guarantee the matching accuracy in the matching algorithms based gravity aided navigation when the initial errors are large. Evolutionary algorithms, which are mostly have the ability of global optimality and fast convergence, can be used to solve the gravity matching problem under large initial errors. However, simply applying evolutionary algorithms to GAINS may lead to false matching. Therefore, in order to deal with the underwater gravity matching problem, it is necessary to improve the traditional evolutionary algorithms. In this paper, an affine transformation based artificial bee colony (ABC) algorithm, which can greatly improve the positioning precision under large initial errors condition, is developed. The proposed algorithm introduces affine transformation to both initialization process and evolutionary process of ABC algorithm. The single-point matching strategy is replaced by the strategy of matching a sequence of several consecutive position vectors. In addition, several constraints are introduced to the process of evolution by using the output characteristics of the inertial navigation system (INS). Simulations based on the actual gravity anomaly base map have been performed for the validation of the proposed algorithm

    Tracking Architecture Based on Dual-Filter with State Feedback and Its Application in Ultra-Tight GPS/INS Integration

    No full text
    If a Kalman Filter (KF) is applied to Global Positioning System (GPS) baseband signal preprocessing, the estimates of signal phase and frequency can have low variance, even in highly dynamic situations. This paper presents a novel preprocessing scheme based on a dual-filter structure. Compared with the traditional model utilizing a single KF, this structure avoids carrier tracking being subjected to code tracking errors. Meanwhile, as the loop filters are completely removed, state feedback values are adopted to generate local carrier and code. Although local carrier frequency has a wide fluctuation, the accuracy of Doppler shift estimation is improved. In the ultra-tight GPS/Inertial Navigation System (INS) integration, the carrier frequency derived from the external navigation information is not viewed as the local carrier frequency directly. That facilitates retaining the design principle of state feedback. However, under harsh conditions, the GPS outputs may still bear large errors which can destroy the estimation of INS errors. Thus, an innovative integrated navigation filter is constructed by modeling the non-negligible errors in the estimated Doppler shifts, to ensure INS is properly calibrated. Finally, field test and semi-physical simulation based on telemetered missile trajectory validate the effectiveness of methods proposed in this paper

    A Changhsingian (late Permian) nautiloid assemblage from Gujiao, South China.

    No full text
    23 pagesInternational audienceA ca. 0.30 m thick cherty limestone bed in the Dalong Formation at Gujiao (Guizhou) has yielded a highly diverse Changhsingian nautiloid assemblage. Its age is late Changhsingian, indicated by the co-occurring ammonoid Pseudotirolites sp. This assemblage is composed of nine species and five taxa in open nomenclature in nine genera, including one new genus and three new species: Neotainoceras zhaoi sp. nov., Nodopleuroceras gujiaoense sp. nov. and Gujiaonautilus longliensis gen. et sp. nov. Sholakoceras is for the first time recorded in South China. Compared with literature data from 52 sites in various regions worldwide, the material described here presents the most diverse Changhsingian nautiloid assemblage. Among the genera of the Gujiao assemblage, Pleuronautilus, Tainoceras and Liroceras are cosmopolitan, while the others are more endemic or genera known so far only from South China

    Aspirin versus LMWH for VTE prophylaxis after orthopedic surgery

    No full text
    Low molecular weight heparin (LMWH) is often used to prevent perioperative venous thrombosis after surgery, but aspirin is also recommended by academics. Studies were searched in electronic databases until February 24, 2023. We performed a meta-analysis to evaluate the safety and efficacy of aspirin and LMWH for venous thromboembolism (VTE) prophylaxis in patients after orthopedic surgery. The outcomes were death from any causes, deep vein thrombosis (DVT), pulmonary embolism (PE), etc. This study was registered with INPLASY, number 202320117. Six randomized controlled trials enrolled 13,851 patients with postoperative joint surgery. The risk of DVT was comparable between the two groups when aspirin was combined with mechanical devices (RR 0.61 [95% CI 0.27–1.39], I² = 62%, P = 0.24). No significant differences in all cause death, PE, wound infection, and wound complication were found between the aspirin and LMWH groups. In this meta-analysis, the mortality rate was comparable between the aspirin and LMWH groups. However, aspirin alone had a higher risk of DVT than LMWH. Based on the results of this meta-analysis, we suggest aspirin combined with mechanical devices for VTE prophylaxis in patients after orthopedic surgery

    Microbiota of long-term indwelling hemodialysis catheters during renal transplantation perioperative period: a cross-sectional metagenomic microbial community analysis

    No full text
    AbstractBackground: Catheter-related infection (CRI) is a major complication in patients undergoing hemodialysis. The lack of high-throughput research on catheter-related microbiota makes it difficult to predict the occurrence of CRI. Thus, this study aimed to delineate the microbial structure and diversity landscape of hemodialysis catheter tips among patients during the perioperative period of kidney transplantation (KTx) and provide insights into predicting the occurrence of CRI.Methods: Forty patients at the Department of Transplantation undergoing hemodialysis catheter removal were prospectively included. Samples, including catheter tip, catheter outlet skin swab, catheter blood, peripheral blood, oropharynx swab, and midstream urine, from the separate pre- and post-KTx groups were collected and analyzed using metagenomic next-generation sequencing (mNGS). All the catheter tips and blood samples were cultured conventionally.Results: The positive detection rates for bacteria using mNGS and traditional culture were 97.09% (200/206) and 2.65% (3/113), respectively. Low antibiotic-sensitivity biofilms with colonized bacteria were detected at the catheter tip. In asymptomatic patients, no statistically significant difference was observed in the catheter tip microbial composition and diversity between the pre- and post-KTx group. The catheter tip microbial composition and diversity were associated with fasting blood glucose levels. Microorganisms at the catheter tip most likely originated from catheter outlet skin and peripheral blood.Conclusions: The long-term colonization microbiota at the catheter tip is in a relatively stable state and is not readily influenced by KTx. It does not act as the source of infection in all CRIs, but could reflect hematogenous infection to some extent
    • …
    corecore