57 research outputs found

    Comparison of contrast-enhanced multidetector computed tomography angiography and splenoportography for the evaluation of portosystemic-shunt occlusion after cellophane banding in dogs

    Get PDF
    BACKGROUND Many patients with a congenital extrahepatic portosystemic shunt (PSS) do not tolerate an immediate shunt closure. Therefore, slow progressive techniques were developed. To evaluate the success of shunt closure diagnostic imaging is essential to identify possible residual blood flow through the shunt vessel. There is a lack of information about the reliability of computed tomography angiography (CTA) for evaluating residual flow through a PSS after treatment. The purpose of this prospective study was to compare the results of CTA with splenoportography. Three months after cellophane banding CTA and splenoportography were performed in 20 dogs and reviewed by three independent examiners, respectively. In both imaging modalities the presences of a residual shunt was judged as present or absent and the extent of visibility of portal vasculature was recorded. RESULTS Based on the evaluation of the splenoportography residual flow through shunt was present in 6 dogs. The classification of residual shunt present or absent showed a substantial to perfect agreement (κ = 0.65-1.00) between the observers in splenoportography and a slight to moderate agreement (κ = 0.11-0.51) for CTA. Sensitivity and specificity varied between 0.50 and 1.00 and 0.57-0.85, respectively. Significant correlation between CTA and splenoportography for the classification of residual shunt was present only in one observer but not in the other two. CONCLUSION More studies were classified as residual shunt positive with CTA compared to splenoportography. It remains unclear which methods do reflect reality better and thus which method is superior. The greater inter-rater agreement for splenoportography suggests a greater reliability of this technique

    Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures.

    Full text link
    Biodegradable self-reinforced poly-L/DL-lactide plates and screws were used for osteosynthesis in 10 consecutive cases of bimaxillary procedures with simultaneous genioplasties, without postoperative rigid intermaxillary fixation. During surgery, data were gathered concerning failure of the osteosynthesis material. Clinical examination was carried out weekly until the sixth postoperative week. Cephalometric analysis of standardized cephalograms was performed to evaluate the short-term skeletal stability pattern, which was compared with similar reports in the literature. Six weeks postoperatively, all jaws were clinically stable and there was no clinical evidence of foreign body reactions. For the whole group (n = 10), the mean maxillary advancement at point A was 2.9 mm with a mean postoperative relapse of 0.0 mm. The mean advancement at point B was 2.8 mm with a mean additional advancement postoperatively of 1.1 mm. The mean vertical surgical displacement at point A was directed inferiorly with a value of 1.8 mm and a relapse of -0.4 mm. At point B the corresponding values were 1.9 mm and -0.4 mm. In the Angle Class III group (n = 4), the mean advancement at A was 5.9 mm with an additional postoperative advancement of 0.3 mm. In the Angle Class II group (n = 6), mean advancement at point B was 4.0 mm, with an additional postoperative advancement of 1.1 mm. In the group with short face deformity (n = 3), the mean inferior movement in ANS was 6.6 mm with a relapse of -0.2 mm. At menton the vertical surgical movement was 13.0 mm with a relapse of -0.2 mm. None of the plates, which were bent at room temperature, broke. The screw heads broke or had an insufficient fit in the bone in 12 of 305 (3.9%) screws. It can be concluded that the tested system of biodegradable self-reinforced poly-L/DL-lactide screws and plates has a small material-related failure rate, and that their application in orthognathic surgery leads to a predictable short-term skeletal stability pattern which is comparable to the 'gold standard' of titanium plates and screws

    Negotiating guilt: God and man as partners in forgiveness and reconciliation

    No full text

    Spiritualiteit als godmenselijk betrekkingsgebeuren

    No full text

    The Communicative Theology of William of Ockham. A contemporary Interpretation.

    No full text
    • …
    corecore