1,165 research outputs found

    Kinematics measurements of regular, irregular, and rogue waves by PIV/LDV

    Get PDF
    A comprehensive experimental study was conducted to produce benchmark wave kinematics data for five different regular waves and the maxima of four different irregular wave trains. Two of the irregular waves generated are in the category of rogue waves. A series of experiments were conducted in a 2-D wave tank at Texas A&M University to measure wave velocities and accelerations using LDV and PIV systems. The wave crests of regular and rogue waves are the focus of this study. With the measured wave velocity field, the wave accelerations were computed using a centered finite difference scheme. Both local and convective components of the total accelerations are obtained from experimental data. Also, the nonlinear wave forces on a truncated slender cylinder are computed by applying the obtained wave kinematics to the Morison equation. The force results based on measured wave kinematics are compared with those based on the kinematics of linear extrapolation, Wheeler stretching, and modified stretching. The Wheeler stretching method generally underestimates the actual wave kinematics. The linear extrapolation method is very sensitive to the cutoff frequency of the wave spectrum. The modified stretching method tends to predict the maximum value of wave kinematics above the still water level (SWL) well except for the convective acceleration. The magnitude of convective acceleration in the regular waves was negligibly small, whereas the magnitudes of horizontal and vertical convective accelerations in the rogue wave were increased rapidly above the SWL

    Metal/graphene sheets as p-type transparent conducting electrodes in GaN light emitting diodes

    Get PDF
    We demonstrate the use of graphene based transparent sheets as a p-type current spreading layer in GaN light emitting diodes (LEDs). Very thin Ni/Au was inserted between graphene and p-type GaN to reduce contact resistance, which reduced contact resistance from similar to 5.5 to similar to 0.6 Omega/ cm(2), with no critical optical loss. As a result, LEDs with metal-graphene provided current spreading and injection into the p-type GaN layer, enabling three times enhanced electroluminescent intensity compared with those with graphene alone. We confirmed very strong blue light emission in a large area of the metal-graphene layer by analyzing image brightness.open281

    Characterization of Fabry mice treated with recombinant adeno-associated virus 2/8-mediated gene transfer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Enzyme replacement therapy (ERT) with α-galactosidase A (α-Gal A) is currently the most effective therapeutic strategy for patients with Fabry disease, a lysosomal storage disease. However, ERT has limitations of a short half-life, requirement for frequent administration, and limited efficacy for patients with renal failure. Therefore, we investigated the efficacy of recombinant adeno-associated virus (rAAV) vector-mediated gene therapy for a Fabry disease mouse model and compared it with that of ERT.</p> <p>Methods</p> <p>A pseudotyped rAAV2/8 vector encoding α-Gal A cDNA (rAAV2/8-hAGA) was prepared and injected into 18-week-old male Fabry mice through the tail vein. The α-Gal A expression level and globotriaosylceramide (Gb3) levels in the Fabry mice were examined and compared with Fabry mice with ERT. Immunohistochemical and ultrastructural studies were conducted.</p> <p>Results</p> <p>Treatment of Fabry mice with rAAV2/8-hAGA resulted in the clearance of accumulated Gb3 in tissues such as liver, spleen, kidney, heart, and brain with concomitant elevation of α-Gal A enzyme activity. Enzyme activity was elevated for up to 60 weeks. In addition, expression of the α-Gal A protein was identified in the presence of rAAV2/8-hAGA at 6, 12, and 24 weeks after treatment. α-Gal A activity was significantly higher in the mice treated with rAAV2/8-hAGA than in Fabry mice that received ERT. Along with higher α-Gal A activity in the kidney of the Fabry mice treated with gene therapy, immunohistochemical studies showed more α-Gal A expression in the proximal tubules and glomerulus, and less Gb3 deposition in Fabry mice treated with this gene therapy than in mice given ERT. The α-gal A gene transfer significantly reduced the accumulation of Gb3 in the tubules and podocytes of the kidney. Electron microscopic analysis of the kidneys of Fabry mice also showed that gene therapy was more effective than ERT.</p> <p>Conclusions</p> <p>The rAAV2/8-hAGA mediated α-Gal A gene therapy provided improved efficiency over ERT in the Fabry disease mouse model. Furthermore, rAAV2/8-hAGA-mediated expression showed a greater effect in the kidney than ERT.</p

    Bax-dependent apoptosis induced by ceramide in HL-60 cells

    Get PDF
    AbstractCeramide is an important lipid messenger involved in mediating a variety of cell functions including apoptosis. In this study, we show that antisense bax inhibits cytochrome c release, poly(ADP-ribose)polymerase cleavage and cell death induced by ceramide in HL-60 cells. In addition, ceramide induces translocation of Bax to mitochondria. The addition of the broad spectrum caspase inhibitor zVAD-fmk prevented ceramide-induced apoptotic cell death but did not inhibit translocation of Bax and mitochondrial cytochrome c release. Furthermore, ceramide inhibits the expression of the antiapoptotic protein Bcl-xL with an increase in the ratio of Bax to Bcl-xL. These data provide direct evidence that Bax plays an important role in regulating ceramide-induced apoptosis

    Manipulation of Rat Movement via Nigrostriatal Stimulation Controlled by Human Visually Evoked Potentials

    Get PDF
    Here, we report that the development of a brain-to-brain interface (BBI) system that enables a human user to manipulate rat movement without any previous training. In our model, the remotely-guided rats (known as ratbots) successfully navigated a T-maze via contralateral turning behaviour induced by electrical stimulation of the nigrostriatal (NS) pathway by a brain-computer interface (BCI) based on the human controller&apos;s steady-state visually evoked potentials (SSVEPs). The system allowed human participants to manipulate rat movement with an average success rate of 82.2% and at an average rat speed of approximately 1.9 m/min. The ratbots had no directional preference, showing average success rates of 81.1% and 83.3% for the left-and right-turning task, respectively. This is the first study to demonstrate the use of NS stimulation for developing a highly stable ratbot that does not require previous training, and is the first instance of a training-free BBI for rat navigation. The results of this study will facilitate the development of borderless communication between human and untrained animals, which could not only improve the understanding of animals in humans, but also allow untrained animals to more effectively provide humans with information obtained with their superior perception.11Ysciescopu

    Ordinary kriging approach to predicting long-term particulate matter concentrations in seven major Korean cities

    Get PDF
    Objectives Cohort studies of associations between air pollution and health have used exposure prediction approaches to estimate individual-level concentrations. A common prediction method used in Korean cohort studies is ordinary kriging. In this study, performance of ordinary kriging models for long-term particulate matter less than or equal to 10 μm in diameter (PM10) concentrations in seven major Korean cities was investigated with a focus on spatial prediction ability. Methods We obtained hourly PM10 data for 2010 at 226 urban-ambient monitoring sites in South Korea and computed annual average PM10 concentrations at each site. Given the annual averages, we developed ordinary kriging prediction models for each of the seven major cities and for the entire country by using an exponential covariance reference model and a maximum likelihood estimation method. For model evaluation, cross-validation was performed and mean square error and R-squared (R2) statistics were computed. Results Mean annual average PM10 concentrations in the seven major cities ranged between 45.5 and 66.0 μg/m3 (standard deviation=2.40 and 9.51 μg/m3, respectively). Cross-validated R2 values in Seoul and Busan were 0.31 and 0.23, respectively, whereas the other five cities had R2 values of zero. The national model produced a higher crossvalidated R2 (0.36) than those for the city-specific models. Conclusions In general, the ordinary kriging models performed poorly for the seven major cities and the entire country of South Korea, but the model performance was better in the national model. To improve model performance, future studies should examine different prediction approaches that incorporate PM10 source characteristics

    The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

    Get PDF
    Background/Aims. To investigate the patterns of retinal ganglion cell damage at different stages of glaucoma, using the circumpapillary retinal nerve fiber layer (RNFL) and macula ganglion cell-inner plexiform layer (GCIPL) thicknesses. Methods. In 296 eyes of 296 glaucoma patients and 55 eyes of 55 healthy controls, the correlations of mean deviation (MD) with the superior and inferior quadrant RNFL/GCIPL thickness (defined as the average of three superior and inferior sectors, resp.) were analyzed. Results. In early to moderate glaucoma, most of the RNFL/GCIPL thicknesses had significant positive correlations with the MD. In advanced glaucoma, the superior GCIPL thickness showed the highest correlation with MD (r=0.495), followed by the superior RNFL (r=0.452) (all; P<0.05). The correlation coefficient of the inferior RNFL thickness with MD (r<0.471) was significantly stronger in early to moderate glaucoma compared to that in advanced glaucoma (r=0.192; P<0.001). In contrast, the correlations of the superior GCIPL thickness with MD (r=0.452) in advanced glaucoma was significantly stronger compared to that in early to moderate glaucoma (r=0.159; P<0.001). Conclusions. The most preserved region in advanced glaucoma appears to be the superior macular GCIPL, whereas the most vulnerable region for initial glaucoma is the inferior RNFL around the optic disc
    corecore