2,688 research outputs found

    Preliminary interpretation of Titan plasma interaction as observed by the Cassini Plasma Spectrometer: Comparisons with Voyager 1

    Get PDF
    The Cassini Plasma Spectrometer (CAPS) instrument observed the plasma environment at Titan during the Cassini orbiter's TA encounter on October 26, 2004. Titan was in Saturn's magnetosphere during the Voyager 1 flyby and also during the TA encounter. CAPS measurements from this encounter are compared with measurements made by the Voyager 1 Plasma Science Instrument (PLS). The comparisons focus on the composition and nature of ambient and pickup ions. They lead to: A) the major ion components of Saturn's magnetosphere in the vicinity of Titan are H+, H-2(+) and O+/CH4+ ions; B) finite gyroradius effects are apparent in ambient O+ ions as the result of their absorption by Titan's extended atmosphere; C) the principal pickup ions are composed of H+, H-2(+), N+/CH2+, CH4+, and N-2(+); D) the pickup ions are in narrow energy ranges; and E) there is clear evidence of the slowing down of background ions due to pickup ion mass loading

    What problems associated with ageing are seen in a specialist service for older people living with HIV?

    Get PDF
    OBJECTIVES: By 2030 the majority of the people living with HIV in the United Kingdom will be over the age of 50. HIV services globally must adapt to manage people living with HIV as they age. Currently these services are often designed based on data from the wider population or from the experiences of HIV clinicians. This article aims to help clinicians designing inclusive HIV services by presenting the most common needs identified during the first year of a specialist clinic for older people living with HIV at the Ian Charleson Day Centre, Royal Free Hospital in London, United Kingdom. METHODS: The records of all thirty-five patients attending the inaugural nine sessions were reviewed. RESULTS: The median age of attendees was 69 (53-93) with 77% being male, 63% being White, 49% being heterosexual and 97% being virally suppressed respectively. The majority (83%) met the criteria for frailty using the Fried frailty phenotype. Eighteen issues linked to ageing were identified with the most common being affective symptoms (51%), memory loss (37%) and falls (29%). CONCLUSIONS: Whilst older people living with HIV are a heterogeneous group frailty is common and appears to present earlier. HIV services either need to adapt to meet these additional needs or must support users in transitioning to existing services. We feel that our multidisciplinary model is successful in identifying problems associated with ageing in people living with HIV and could be successfully replicated elsewhere

    Smooth-muscle myosin mutations in hereditary non-polyposis colorectal cancer syndrome

    Get PDF
    We examined adenomas and cancers from hereditary non-polyposis colorectal cancer (HNPCC) syndrome patients for the presence of frameshift mutations in the smooth-muscle myosin gene, MYH11. Our results show that mutations in MYH11 occur more frequently in cancers than adenomas (P=0.008) and are dependent on microsatellite instability (MSI+)

    Preliminary results on Saturn's inner plasmasphere as observed by Cassini: Comparison with Voyager

    Get PDF
    We present an analysis of Saturn's inner plasmasphere as observed by the Cassini Plasma Spectrometer ( CAPS) experiment during Cassini's initial entry into Saturn's magnetosphere when the spacecraft was inserted into orbit around Saturn. The ion fluxes are divided into two subgroups: protons and water group ions. We present the relative amounts of these two groups and the first estimates of their fluid parameters: ion density, flow velocity and temperature. We also compare this data with electron plasma measurements. Within the plasmasphere and inside of Enceladus' orbit, water group ions are about a factor of similar to 10 greater than protons in number with number densities exceeding 40 cm(-3). Within this inner region the spacecraft acquires a negative potential so that the electron density is underestimated. The electron and proton temperatures, which could not be measured in this region by Voyager, are T similar to 2 eVat L similar to 3. Also, within this inner region the protons, because of a negative spacecraft potential, appear to be super-corotating. By enforcing the condition that protons and water group ions are co-moving we may be able to acquire an independent estimate of the spacecraft potential relative to that estimated when comparing ion-electron measurements. Using our estimates of plasma properties, we estimate the importance of the rotating plasma on the stress balance equation for the inner magnetosphere and corresponding portion of the ring current

    Preliminary results on Saturn's inner plasmasphere as observed by Cassini: Comparison with Voyager

    Get PDF
    We present an analysis of Saturn's inner plasmasphere as observed by the Cassini Plasma Spectrometer ( CAPS) experiment during Cassini's initial entry into Saturn's magnetosphere when the spacecraft was inserted into orbit around Saturn. The ion fluxes are divided into two subgroups: protons and water group ions. We present the relative amounts of these two groups and the first estimates of their fluid parameters: ion density, flow velocity and temperature. We also compare this data with electron plasma measurements. Within the plasmasphere and inside of Enceladus' orbit, water group ions are about a factor of similar to 10 greater than protons in number with number densities exceeding 40 cm(-3). Within this inner region the spacecraft acquires a negative potential so that the electron density is underestimated. The electron and proton temperatures, which could not be measured in this region by Voyager, are T similar to 2 eVat L similar to 3. Also, within this inner region the protons, because of a negative spacecraft potential, appear to be super-corotating. By enforcing the condition that protons and water group ions are co-moving we may be able to acquire an independent estimate of the spacecraft potential relative to that estimated when comparing ion-electron measurements. Using our estimates of plasma properties, we estimate the importance of the rotating plasma on the stress balance equation for the inner magnetosphere and corresponding portion of the ring current

    Ultrasonic Characterization of Microspherical Inclusions in Zirconia and Crystallized Glass

    Full text link
    In high performance ceramic materials the critical flaw size is ≃ 10 µm. Not all inclusions are equally detrimental to the structural properties. Therefore it is necessary to determine their size and composition.</p

    Explicit attention interferes with selective emotion processing in human extrastriate cortex

    Get PDF
    BACKGROUND: Brain imaging and event-related potential studies provide strong evidence that emotional stimuli guide selective attention in visual processing. A reflection of the emotional attention capture is the increased Early Posterior Negativity (EPN) for pleasant and unpleasant compared to neutral images (~150–300 ms poststimulus). The present study explored whether this early emotion discrimination reflects an automatic phenomenon or is subject to interference by competing processing demands. Thus, emotional processing was assessed while participants performed a concurrent feature-based attention task varying in processing demands. RESULTS: Participants successfully performed the primary visual attention task as revealed by behavioral performance and selected event-related potential components (Selection Negativity and P3b). Replicating previous results, emotional modulation of the EPN was observed in a task condition with low processing demands. In contrast, pleasant and unpleasant pictures failed to elicit increased EPN amplitudes compared to neutral images in more difficult explicit attention task conditions. Further analyses determined that even the processing of pleasant and unpleasant pictures high in emotional arousal is subject to interference in experimental conditions with high task demand. Taken together, performing demanding feature-based counting tasks interfered with differential emotion processing indexed by the EPN. CONCLUSION: The present findings demonstrate that taxing processing resources by a competing primary visual attention task markedly attenuated the early discrimination of emotional from neutral picture contents. Thus, these results provide further empirical support for an interference account of the emotion-attention interaction under conditions of competition. Previous studies revealed the interference of selective emotion processing when attentional resources were directed to locations of explicitly task-relevant stimuli. The present data suggest that interference of emotion processing by competing task demands is a more general phenomenon extending to the domain of feature-based attention. Furthermore, the results are inconsistent with the notion of effortlessness, i.e., early emotion discrimination despite concurrent task demands. These findings implicate to assess the presumed automatic nature of emotion processing at the level of specific aspects rather than considering automaticity as an all-or-none phenomenon

    Does inter-vertebral range of motion increase after spinal manipulation? A prospective cohort study.

    Get PDF
    Background: Spinal manipulation for nonspecific neck pain is thought to work in part by improving inter-vertebral range of motion (IV-RoM), but it is difficult to measure this or determine whether it is related to clinical outcomes. Objectives: This study undertook to determine whether cervical spine flexion and extension IV-RoM increases after a course of spinal manipulation, to explore relationships between any IV-RoM increases and clinical outcomes and to compare palpation with objective measurement in the detection of hypo-mobile segments. Method: Thirty patients with nonspecific neck pain and 30 healthy controls matched for age and gender received quantitative fluoroscopy (QF) screenings to measure flexion and extension IV-RoM (C1-C6) at baseline and 4-week follow-up between September 2012-13. Patients received up to 12 neck manipulations and completed NRS, NDI and Euroqol 5D-5L at baseline, plus PGIC and satisfaction questionnaires at follow-up. IV-RoM accuracy, repeatability and hypo-mobility cut-offs were determined. Minimal detectable changes (MDC) over 4 weeks were calculated from controls. Patients and control IV-RoMs were compared at baseline as well as changes in patients over 4 weeks. Correlations between outcomes and the number of manipulations received and the agreement (Kappa) between palpated and QF-detected of hypo-mobile segments were calculated. Results: QF had high accuracy (worst RMS error 0.5o) and repeatability (highest SEM 1.1o, lowest ICC 0.90) for IV-RoM measurement. Hypo-mobility cut offs ranged from 0.8o to 3.5o. No outcome was significantly correlated with increased IV-RoM above MDC and there was no significant difference between the number of hypo-mobile segments in patients and controls at baseline or significant increases in IV-RoMs in patients. However, there was a modest and significant correlation between the number of manipulations received and the number of levels and directions whose IV-RoM increased beyond MDC (Rho=0.39, p=0.043). There was also no agreement between palpation and QF in identifying hypo-mobile segments (Kappa 0.04-0.06). Conclusions: This study found no differences in cervical sagittal IV-RoM between patients with non-specific neck pain and matched controls. There was a modest dose-response relationship between the number of manipulations given and number of levels increasing IV-RoM - providing evidence that neck manipulation has a mechanical effect at segmental levels. However, patient-reported outcomes were not related to this

    Does clinical method mask significant VTE-related mortality and morbidity in malignant disease?

    Get PDF
    After more than 150 years of a recognised link between cancer and vascular thromboembolic events (VTE), and despite a greatly improved understanding of its pathophysiology, epidemiology and treatment, the management of patients with cancer and VTE is still limited. Limitations can be related to the thromboembolism itself, the underlying cancer, or to the management process. There is significant literature that deals with the first two, but very little regarding the systems we use, or how the inadequacies in documentation, identification and classification of VTE affect the cancer patients themselves. This review aims to raise awareness of this neglected area and stimulate research that may lead to improvements in patient care

    MAXIPOL: a balloon-borne experiment for measuring the polarization anisotropy of the cosmic microwave background radiation

    No full text
    We discuss MAXIPOL, a bolometric balloon-borne experiment designed to measure the E-mode polarization anisotropy of the cosmic microwave background radiation (CMB) on angular scales of 10 arcmin to 2 degrees. MAXIPOL is the first CMB experiment to collect data with a polarimeter that utilizes a rotating half-wave plate and fixed wire-grid polarizer. We present the instrument design, elaborate on the polarimeter strategy and show the instrument performance during flight with some time domain data. Our primary data set was collected during a 26 hour turnaround flight that was launched from the National Scientific Ballooning Facility in Ft. Sumner, New Mexico in May 2003. During this flight five regions of the sky were mapped. Data analysis is in progress
    corecore