7,957 research outputs found

    Smooth-Particle Phase Stability with density and density-gradient potentials

    Full text link
    Stable fluid and solid particle phases are essential to the simulation of continuum fluids and solids using Smooth Particle Applied Mechanics. We show that density-dependent potentials, such as Phi=(1/2)Sum (rho-rho_0)^2, along with their corresponding constitutive relations, provide a simple means for characterizing fluids and that a special stabilization potential, Phi=(1/2)Sum (delrho)^2, not only stabilizes crystalline solid phases (or meshes) but also provides a surface tension which is missing in the usual density-dependent-potential approach. We illustrate these ideas for two-dimensional square, triangular, and hexagonal lattices.Comment: 10 pages, 5 figure

    Extended range X-ray telescope

    Get PDF
    An X-ray telescope system is described which is comprised of a tubular mount having a collecting region remote from the one axial end. A soft X-ray/XUV subsystem associated with the collecting region directs only relatively soft, near on-axis X-rays/XUV radiation incident on a first portion of the collecting region into a first detector sensitive to relatively soft X-rays/XUV radiation. A hard X-ray subsystem associated with the collecting region directs only relatively hard near on-axis X-rays incident on a second portion of the collecting region into a second detector sensitive to relatively hard X-rays

    A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

    Get PDF
    Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine

    Three mirror glancing incidence system for X-ray telescope

    Get PDF
    A telescope suitable for soft X-ray astronomical observations consists of a paraboloid section for receiving rays at a grazing angle and a hyperboloid section which receives reflections from the paraboloid at a grazing angle and directs them to a predetermined point of focus. A second hyperboloid section is centrally located from the other two surfaces and positioned to reflect from its outer surface radiation which was not first reflected by the paraboloid. A shutter is included to assist in calibration

    Apollo experience report: Flight-control data needs, terminal display devices, and ground system configuration requirements

    Get PDF
    The development of flight-control facilities for the Apollo program is reviewed from the viewpoint of the user organization. These facilities are treated in three categories: data systems, ground-based display and control systems, and configuration management. The effects of certain Apollo program factors on the selection, sizing, and configuration management of these systems are discussed. Recommendations are made regarding improvement of the systems and the reduction of system sensitivity to the program factors

    Multispectral glancing incidence X-ray telescope

    Get PDF
    A multispectural glancing incidence X-ray telescope is illustrated capable of broadband, high-resolution imaging of solar and stellar X-ray and extreme ultraviolet radiation sources which includes a primary optical system preferably of the Wolter I type having a primary mirror system. The primary optical system further includes an optical axis having a primary focus at which the incoming radiation is focused by the primary mirrors. A plurality of ellipsoidal mirrors are carried at an inclination to the optical axis behind the primary focus. A rotating carrier is provided on which the ellipsoidal mirrors are carried so that a desired one of the ellipsoidal mirrors may be selectively positioned in front of the incoming radiation beam. In the preferred embodiment, each of the ellipsoidal mirrors has an identical concave surface carrying a layered synthetic microstructure coating tailored to reflect a desired wavelength of 1.5A or longer. Each of the identifical ellipsoidal mirrors has a second focus at which a detector is carried. Thus the different wavelength image is focused upon the detector irregardless of which mirror is positioned in front of the radiation beam

    Nonequilibrium Temperature and Thermometry in Heat-Conducting Phi-4 Models

    Full text link
    We analyze temperature and thermometry for simple nonequilibrium heat-conducting models. We show in detail, for both two- and three-dimensional systems, that the ideal gas thermometer corresponds to the concept of a local instantaneous mechanical kinetic temperature. For the Phi-4 models investigated here the mechanical temperature closely approximates the local thermodynamic equilibrium temperature. There is a significant difference between kinetic temperature and the nonlocal configurational temperature. Neither obeys the predictions of extended irreversible thermodynamics. Overall, we find that kinetic temperature, as modeled and imposed by the Nos\'e-Hoover thermostats developed in 1984, provides the simplest means for simulating, analyzing, and understanding nonequilibrium heat flows.Comment: 20 pages with six figures, revised following review at Physical Review

    Spectral slicing X-ray telescope with variable magnification

    Get PDF
    A telescope for viewing high frequency radiation (soft X-ray, extreme ultraviolet) is described. This telescope has a long focal length with a selection of magnifications despite a short housing. Light enters the telescope and is reflected by the telescope's primary optical system to one of several secondary mirrors at different locations on a movable frame. The secondary mirrors have varying degrees of magnification and select narrow spectral slices of the incident radiation. Thus, both the magnification and effective focal length field of view and wavelength can be altered by repositioning the moving frame. Configurations for spaceborne applications are discussed

    Multiplate focusing collimator

    Get PDF
    An appartus is described for scanning relatively small near sources of penetrating radiation to obtain the energy distribution thereof, wherein a collimator assembly is interposed between a radiation source and a radiation detector. The collimator assembly has a plurality of plates aligned in parallel planes with respect to a common axis normal to their centers. All the plates have similar random distribution of apertures. All apertures on each plate are the same size. The size of respective plates, the size of the apertures of said respective plates, and the spacing between said respective plates vary precisely according to a predetermined ratio to produce radiation channels which converge to a focal point. The radiation incident to the radiation detector is maximized when the focal point and the radiation source are co-incident

    Method for retarding dye fading during archival storage of developed color photographic film

    Get PDF
    Dye fading during archival storage of developed color photographic film is retarded by placing the film in a sealed, opaque vault, introducing a dry, pressurized inert gas into the vault while the latter is vented, and sealing the vault after the air within the vault has been purged and replaced by the inert gas. Preferably, the gas is nitrogen; and the vault is stored at a temperature below room temperature to preserve the color photographic emulsions on the film contained within the vault. For short-term storage, sodium thiocyanate pads charged with water are placed within the vault. For long term storage, the interior of the vault is kept at a low relative humidity
    corecore