32,509 research outputs found

    Trilingual conversations: a window into multicompetence

    Get PDF
    A recurrent theme in the literature on trilingual language use is the question of whether there is a specific “trilingual competence.” In this paper we consider this question in the light of codeswitching patterns in two dyadic trilingual conversations between a mother and daughter conducted in (Lebanese) Arabic, French, and English. Quantitative and qualitative analysis of codeswitching in both conversants shows that, despite the fact that both subjects are fluent in all three languages, uses of switching are significantly different for mother and daughter across a number of features, including relative frequency of different switch types, and the incidence of hybrid constructions involving items from two or more languages. The subjects appear to display qualitatively distinct profiles of competence in the trilingual mode. This in turn leads to the conclusion that the facts of trilingual language use are best characterized in terms of “multicompetence” (Cook, 1991). The paper concludes with some further reflections on the uniqueness of trilingual language use (an “old chestnut” in trilingualism research, cf. Klein, 1995)

    Probabilistic Planning via Heuristic Forward Search and Weighted Model Counting

    Full text link
    We present a new algorithm for probabilistic planning with no observability. Our algorithm, called Probabilistic-FF, extends the heuristic forward-search machinery of Conformant-FF to problems with probabilistic uncertainty about both the initial state and action effects. Specifically, Probabilistic-FF combines Conformant-FFs techniques with a powerful machinery for weighted model counting in (weighted) CNFs, serving to elegantly define both the search space and the heuristic function. Our evaluation of Probabilistic-FF shows its fine scalability in a range of probabilistic domains, constituting a several orders of magnitude improvement over previous results in this area. We use a problematic case to point out the main open issue to be addressed by further research

    Hydrological connectivity inferred from diatom transport through the riparian-stream system

    Get PDF
    Funding for this research was provided by the Luxembourg National Research Fund (FNR) in the framework of the BIGSTREAM (C09/SR/14), ECSTREAM (C12/SR/40/8854) and CAOS (INTER/DFG/11/01) projects. We are most grateful to the Administration des Services Techniques de l’Agriculture (ASTA) for providing meteorological data. We also acknowledge Delphine Collard for technical assistance in diatom sample treatment and preparation, François Barnich for the water chemistry analyses, and Jean-François Iffly, Christophe Hissler, JĂ©rĂŽme Juilleret, Laurent Gourdol and Julian Klaus for their constructive comments on the project and technical assistance in the field.Peer reviewedPublisher PD

    In-situ measurement of the permittivity of helium using microwave NbN resonators

    Full text link
    By measuring the electrical transport properties of superconducting NbN quarter-wave resonators in direct contact with a helium bath, we have demonstrated a high-speed and spatially sensitive sensor for the permittivity of helium. In our implementation a ∌10−3\sim10^{-3} mm3^3 sensing volume is measured with a bandwidth of 300 kHz in the temperature range 1.8 to 8.8 K. The minimum detectable change of the permittivity of helium is calculated to be ∌6×\sim6\times10−1110^{-11} Ï”0\epsilon_0/Hz1/2^{1/2} with a sensitivity of order 10−1310^{-13} Ï”0\epsilon_0/Hz1/2^{1/2} easily achievable. Potential applications include operation as a fast, localized helium thermometer and as a transducer in superfluid hydrodynamic experiments.Comment: 4 pages, 3 figure

    Enhancement of perfluorooctanoate and perfluorooctanesulfonate activity at acoustic cavitation bubble interfaces

    Get PDF
    Acoustic cavitation driven by ultrasonic irradiation decomposes and mineralizes the recalcitrant perfluorinated surfactants perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA). Pyrolytic cleavage of the ionic headgroup is the rate-determining step. In this study, we examine the sonochemical adsorption of PFOX, where X = S for PFOS and A for PFOA, by determining kinetic order and absolute rates over an initial PFOX concentration range of 20 nM to 200 ÎŒM. Sonochemical PFOX kinetics transition from pseudo-first-order at low initial concentrations, [PFOX]_i 40 ÎŒM, as the bubble interface sites are saturated. At PFOX concentrations below 100 ÎŒM, concentration-dependent rates were modeled with Langmuir−Hinshelwood (LH) kinetics. Empirically determined rate maximums, V_(Max)^(−PFOA) = 2230 ± 560 nM min^−1 and V_(Max)^(−PFOS) = 230 ± 60 nM min^−1, were used in the LH model, and sonochemical surface activities were estimated to be K_(Sono)^(PFOS) = 120000 M^−1 and K_(Sono)^(PFOA) = 28500 M^−1, 60 and 80 times greater than equilibrium surface activities, K_(Eq)^(PFOS) and K_(Eq)^(PFOA). These results suggest enhanced sonochemical degradation rates for PFOX when the bubble interface is undersaturated. The present results are compared to previously reported sonochemical kinetics of nonvolatile surfactants

    Fracture strength and Young's modulus of ZnO nanowires

    Get PDF
    The fracture strength of ZnO nanowires vertically grown on sapphire substrates was measured in tensile and bending experiments. Nanowires with diameters between 60 and 310 nm and a typical length of 2 um were manipulated with an atomic force microscopy tip mounted on a nanomanipulator inside a scanning electron microscope. The fracture strain of (7.7 +- 0.8)% measured in the bending test was found close to the theoretical limit of 10% and revealed a strength about twice as high as in the tensile test. From the tensile experiments the Young's modulus could be measured to be within 30% of that of bulk ZnO, contrary to the lower values found in literature.Comment: 5 pages, 3 figures, 1 tabl

    Instrument to collect fogwater for chemical analysis

    Get PDF
    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3–100-”m diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs
    • 

    corecore